Zero Energy Hotels and Sustainable Mobility in the Islands of Aegean Sea (Greece) ()
Received 10 December 2015; accepted 2 May 2016; published 5 May 2016
1. Introduction
The island of Rhodes (Greece) is located at the crossroads of two major sea routes of the Mediterranean between the Aegean Sea and the coast of the Middle East, as well as Cyprus and Egypt. Its position in southeastern Greece allows to the island to have the longest summer of any of the Greek Islands and a tourist season that starts before April and ends sometime in November.
The insertion of the project is on the island of Rhodes as an exemplary place in the Mediterranean basin due to one of its peculiarities like a very touristic location, and consequently with high need of accommodation buildings, and with high renewable energy sources potentiality.
The project can be replicated in similar climatic areas using the same design concepts, but each time, adapting materials and indigenous building techniques (Figure 1).
The characteristics of the place make the landscape a significant challenge for the characteristics of the climate [3] .
An assessment of the requirements of a sustainable building has made a preliminary study on bioclimatic analysis; solar control; induced natural ventilation; the energy contribution of passive systems for heating, ventilation and cooling with geothermal support [4] (Figure 2, Table 1).
To do this, it is important to know the context of the climate.
The climate data indicate a great availability of solar radiation but also the need to be strongly air-conditioned environments during the spring/summer (Figure 3, Table 2).
2. Bioclimatic Architecture & Active Solar Systems: A Multi-Functional Envelope That Takes into Account Summer Comfort
The envelope becomes multi-functional: It allows both to protect from the outside environment, but also to draw its energy (from the sun, the outdoor air, the soil, the wind…). Thermal mass and insulation, solar protection, ventilation, day lighting are thus associated; a well-designed envelope can avoid or remove the use of traditional installations of heating or air-conditioning.
Figure 2. Area’s global horizontal irradiation.
Being a hot-arid climate is fundamental the proper use of the thermal mass, which is the property of heavy materials to retain long heat or cold and release it over time; this technique also allows to slow down the thermal lag between the external temperature and the internal one.
Climate chart Rhodes-south Aegean.
Table 2. Synthesis of climate data.
Microclimate and project: taking into account the local climate and site context, specific cooling strategies can be selected to apply that are most appropriate to prevent overheating through the building envelope. The microclimate can play a huge role in determining the location of the building more favorable analysis of the combined availability of sun and wind. The graph bioclimatic, solar chart and the compass are important design tools in the application of this technique.
Solar control: to contribute effectively to minimize solar heat gains are calculated a correct shading system [5] . Shadow is transparent and opaque surfaces of the building will minimize the amount of solar radiation that causes overheating in both the interiors and the building structure. Shadowing the structure of the building, the captured heat gain through windows and masonry parts will be reduced.
Building form and layout: building orientation and an optimal distribution of the interior spaces can prevent overheating. The rooms can be divided into zones inside buildings, in order to fend off the sources of internal heat gain and/or assignment heat gains where they can be useful, considering the different construction activities. For example, the creation of a plan of flat and horizontal surface will increase the effectiveness of the cross- ventilation through the plane. Identification of areas can take advantage of vertical temperature stratification (Figure 4).
The use of flap type openings on the back and in the upper position will contribute chimney effect due to the difference of pressure and air temperature.
Typically, building zones in the upper levels are warmer than the lower zones due to stratification; vertical zoning of spaces and activities uses this temperature stratification to accommodate zone uses according to their temperature requirements. Form factor (i.e. the ratio between volume and surface) also plays a major role in the building’s energy and thermal profile. This ratio can be used to shape the building form to the specific local climate [6] . For example, more compact forms tend to preserve more heat than less compact forms because the ratio of the internal loads to envelope area is significant.
Thermal insulation-insulation of the building envelope decreases the amount of heat transferred by radiation through the walls [7] . Since roofs could be a bigger contribution to the internal heat load, the entire roof is considered as a single solar photovoltaic; therefore, there is a gap between the cover PV and the slab which greatly increases the isolation of the interior.
(a)(b)
Figure 4. (a) (b): Passive design application on resort.
Behavioral and occupancy patterns-Some building management policies such as limiting the amount of people in a given area of the building can also contribute effectively to the minimization of heat gains inside a building. Building occupants can also contribute to indoor overheating prevention by: shutting off the lights and equipment of unoccupied spaces, operating shading when necessary to reduce solar heat gains through windows, or dress lighter in order to adapt better to the indoor environment by increasing their thermal comfort tolerance.
Internal gain control: More energy-efficient lighting and electronic equipment tend to release less energy thus contributing to less internal heat loads inside the space [8] .
We proceed now to calculate what might be the energy contribution on the estimated demand for summer cooling of a system of pipelines placed below the building in question.
In other words, it provides for a network of ducts for the pre-cooling of the incoming air. The value of coverage of the requirements depend on the milker of the conduits, the diameter and the length over which the material that might help or not the heat exchange between air and ground [9] (Figure 5).
3. Thermal and Cooling Devices
For the calculation of energy performance and relationship building throughout the formation of the outer wall it is useful to know the main features [10] (Table 3).
Certainly the relative performance of thermal insulation in order to preserve the heat in the cold months is not predominant since the main requirement to the structure required is the function of thermal mass and especially of phase shift.
Summarizing is set out below the main calculations related to the energy of the building structure
Heating Demand 19.8 kWh/(m2a)
Heating Load 28.0 W/m2
Cooling Demand 6.6 kWh/(m2a)
Cooling Load 60.0 W/m2
Airtightness 0.6 1/h
Primary Energy 15.0 kWh/(m2a)
The generation of heating and cooling uses is made using high-efficiency heat pumps with a coefficient of performance (COP) of 3.5/4. The building is then applied electrically and the system of internal parts of the exhausted air will benefit from a heat exchange with the ground below the building.
To increase the efficiency of the building envelope it is equipped with a heat exchanger with the ground consisting of standard tunnel located under the foundations, cast in concrete
The Fraction of thermal load covered by the system, calculated with Ashrae and Trnsys software, is about 38% while the cost of such geothermal system pre-heating or pre-cooling is negligible as it is exploited the thermal mass of the foundation of the building.
4. Photovoltaics
The roof of the building is able to accommodate a photovoltaic solar plant to an area of approximately 100 square meters.
Considering a useful technology for the hot and arid zones such as that of amorphous silicon or CIS, Which is synonymous with CIGS stands for the constituents copper (Cu), indium (In), gallium (Ga) and selenium (Se) with an efficiency of 12% on standard test conditions (STC) of 1000 W/m², we are able to provide for a system of total power 8 kWp [11] (Table 4, Table 5).
The production of electricity is much higher than the sum of the heat demand, cooling, domestic hot water production, mechanical ventilation and lighting devices (Figure 6, Figure 7).
Table 3. Envelope energy performance.
Table 5. Average annual PV electricity production and global irradiation.
Ed: Average daily electricity production from the given system (kWh); Em: Average monthly electricity production from the given system (kWh); Hd: Average daily sum of global irradiation per square meter received by the modules of the given system (kWh/m2); Hm: Average sum of global irradiation per square meter received by the modules of the given system (kWh/m2).
Figure 6. Diagram of PV production in kWh/mouth.
Figure 7. Diagram of sun height and horizon line.
The production of electrical energy is much higher than the overall requirements of the building.
Systems are then used for generating heat and cold as efficient heat pumps for the heating requirements, cooling, domestic hot water production, mechanical ventilation and lighting devices.
The entire energy consumption, thanks to the choices of materials, techniques and passive design of the building is covered by the energy production of the only solar photovoltaic system [12] .
The energy production is much higher than the requirement but can occur at different times from the use. It is therefore necessary to provide the system-building of a storage facility capable of accumulating excess energy produced during daylight hours and make it available at night time [13] .
Storage will consist of a charger for an energy of 6.4 kWh/day; the useful energy to recharge daily will be provided by the photovoltaic system in about 1 - 2 hours of production. As seen from the graph below there is a surplus of usable energy in a smart grid or usable for the production of hydrogen.
The chart above shows the energy balance of the building system. The surplus of electrical energy produced can be used to power a smart grid and to produce hydrogen through the electrolysis of water (Figure 8).
The hydrogen can then be stored and used for electric vehicles equipped with fuel cells.
The efficiency of the system is certainly less than the self-consumption but this way you can transform energy into a vector for a different use.
The efficiency of the system is certainly less than the self-consumption but this way you can transform energy into a vector for a different use.
In fact, when the storage is recharged energy would be fed into the grid while still making its inefficient production
5. Hydrogen Production
To calculate the amount of energy used to produce hydrogen is necessary to check the efficiency of the transformation.
As shown in the preceding diagrams, the split (yield = 70%) of a liter of water in its components H2 and O2, for example, requires approximately 6.3 kWh of electrical energy. The energy content of the hydrogen thus produced (approximately 1.3 m3) corresponds to approximately 4.41 kWh of chemical energy (Figure 9).
If one obtains again electricity from 1.36 m3 of hydrogen with the use of a combined cycle or of a fuel cell it would be obtained approximately 2.2 kWh of electrical energy.
The numbers given above might make it appear questionable and very inconvenient technology of electrolysis for hydrogen production. In fact, the above described process may be interesting in certain conditions. Consider the use of solar energy in the summer (low cost, abundance) in the climate of the Aegean and the exploitation of hydrogen stored for electric mobility. In this case, the analysis could be more favorable from the point of view of economic as well as ecological.
In fact even if the electrolysis is the most straightforward method for the production of pure hydrogen encounters major obstacles to the limited amount of product and for the costs are still too high, due to the use of
Figure 8. Daily electric Balance (Dynamic simulation at 15 May).
Figure 9. Process efficiency in hydrogen’s production by electrolysis.
electrical energy. Currently, only 4% of world production of hydrogen by electrolysis takes place [14] .
In the present case, the availability of surplus energy and the possibility of storing hydrogen and its end-use for the mobility fuel cell make the production useful from the environmental point of view.
6. Hydrogen Utilization: Fuel Cells
The Fuel Cell Technologies should be a comprehensive portfolio of activities that address the full range of barriers facing the development and deployment of hydrogen and fuel cells with the ultimate goals of decreasing our dependence on oil, reducing carbon emissions, and enabling clean, reliable power generation.
One of the advantages of fuel cells is that hydrogen fuel can be derived using a variety of domestic resources such as biomass, water electrolysis, natural gas, propane, and methanol. Hydrogen generated by water electrolysis, which is the splitting of water molecules into hydrogen and oxygen using electricity, can be beneficial when used in combination with variable renewable energy technologies such as solar and wind. When the electricity used for water electrolysis is produced by a variable renewable energy source, the hydrogen stores the unused energy for later use and is classified as a renewable fuel and energy resource.
Fuel cells have been used for many years in the space program to provide electricity and drinking water for astronauts as well as industrial applications. The applications are classified into the following three categories: transportation, stationary power stations, and portable power. This overview focuses on stationary power station applications.
Benefits and advantages of fuel cell technologies include:
・ Near zero emissions at the point of operation
・ Reduction in current and future electricity costs through the efficient use of renewable energy technologies
・ A high-quality, reliable, and consistent power supply as long as fuel is supplied
・ Higher electrical efficiency than traditional combustion power supplies
・ Combined heat and power installations of fuel cells, which further increases efficiency by utilizing the heat generated by the fuel cell for building heating needs
・ Fuel-flexibility, enabling the use of a variety of domestic energy sources (e.g. hydrogen, natural gas, and methanol)
・ Silent operation 24 hours per day, 7 days per week
・ A wide range of applications to choose from.
This overview is intended to provide specific details for Federal Agencies considering fuel cells and renewable hydrogen as part of a construction project (Figure 10, Table 6).
It is possible to allocate 3500 kWh per year for the production of about 555 m3 of hydrogen usable for mobility.
The energy balance [15] of the above graph clearly shows that the energy needs of a building with low consumption can be more than covered by a system of production such as solar PV and that the excess energy produced can be useful for producing hydrogen for use in mobility (Figure 11).
7. Conclusions
Low Mediterranean region is a hot spot for solar technology in general as conventional energy prices as well as solar radiation are very high. With the Bioclimatic techniques, mass and natural ventilation strategies and solar systems for electric, heating and cooling supply Zero Energy Building becomes highly innovative, replicable and really environmental project in this region [16] .
Energy balance demonstrates that exceed solar energy can be useful in hydrogen production for fuel cells vehicle use too.
Starting from a low energy building, the system is globally sustainable in terms of efficiency, use of resources, positive impact on other subsystems not only built environment.
The entire development will feature 8 kW of photovoltaic panels, which will generate about 36 kWh of electricity each day, 13,200/y to supply high efficiency heating and cooling systems [17] .
Some of the excess energy will be stored in a 6.4 kWh lithium-ion battery banks, then, by applying an electrical current to water, electrolytes will be used to turn much of the rest of the excess power into hydrogen gas.
Through the computations of the annual energy balance [18] between building demand and supply energy, it is shown that the extra energy produced by the solar generation system is used also for the hydrogen sustainable mobility.
Key Points
Building annual consumption: 9700 kWh/y
PV Annual Production: 13,200 kWh/y
Excess Energy: 3500 kWh/y
H2 generation from excess energy: 555 m3/y