Acute Effect of Mobile Phone on Cardiac Electrical Activity in Healthy Volunteers ()
1. Introduction
The use of mobile phone has been increasing dramatically in the past decade. World Health Organization has estimated that currently there are 4.6 billion subscriptions globally [1] . The current digital global system for mobile communication (GSM) operates through radiofrequencies (RF) ranges from 900 MHz to 1800 MHz [2] .
Various studies have revealed that the exposure to RF leads to adverse effects on reproductive system, cardiovascular system, autonomic nervous system as well as immune system [3] -[6] . Both human epidemiological studies and animal based (experimental) studies are demonstrating the carcinogenic potential of RF generated electromagnetic field (EMF) [7] [8] .
Though the mobile phone companies are reassuring the safety of their devices, animal studies as well as epidemiological studies show the harmful effects of mobile phone on biological systems. So, the public interest for the hazardous effects of mobile phone on human health has risen.
Research on the effect of mobile phone on cardiovascular system has yielded controversial results. So, we have carried out this study to determine the effects of mobile phone on electrical cardiac activity by analyzing the heart rate, QT interval, and corrected QT Interval (QTC) and QT dispersions (QTd) while the mobile phone is to the proximity of heart of healthy human.
2. Materials and Methods
This was prospective, non-randomized and single center study carried out from January 2010 to January 2012 in Electrocardiogram (ECG) lab of private tertiary care hospital of Karnataka. The study protocol was approved by the institutional ethics committee of the hospital prior to the commencement of the study. The clinical study was performed in accordance with International Conference on Harmonisation-Good Clinical Practice (ICH-GCP) guideline. Informed consent was obtained from all the participants recruited in the study.
One hundred healthy human volunteers were included in the study as per following inclusion and exclusion criteria.
Inclusion Criteria:
• Normal cardiovascular examination;
• Normal baseline ECG and echocardiogram—to confirm the normal structural and functional cardiovascular status.
Exclusion Criteria:
• If the patient is diagnosed to have right bundle branch block (RBBB) and left bundle branch block (LBBB) during ECG examination;
• If the patient is diagnosed with structural heart abnormalities, ischemic or rheumatic heart disease, left ventricular dysfunction during ECG or echocardiography;
• If the patient having hypertension, diabetes, thyroid disorder or electrolyte imbalance.
2.1. Description of Study Procedure
The participants were asked not to drink tea, coffee or cola containing beverages or alcohol before 24-hour of ECG recording to minimize the effect of these factors on ECG variables or heart rate. The participants were requested not to use mobile phone before 24-hour of the recording of the ECG.
We used Nokia 2600 MP (2G, GSM 900/1800, Nokia Corporation, Helsinki, Finland) to study the effect of RF on heart rate and ECG variables. The mobile phone was set into silent mode (non-vibrating mode) so that the patients were not able to understand whether it is ringing, on or off. The phone was placed in the left pocket of the shirt (anterior wall of the chest).
ECG was used for 12-lead ECG recording of the participants (supine position). The 12-lead ECG (baseline) was recorded using ECG machine (Philips Pagewriter TC 20) when mobile was not nearby the participant. 2nd ECG was taken with the mobile phone on his left pocket-anterior chest wall and switched on (silent mode, not vibrating), but not ringing. 3rd ECG was taken with the mobile phone switched on, and ringing (silent mode, but not vibrating), on the same spot on the left anterior chest wall.
We have used software (Philips DXL ECG Algorithm) for analysis of various ECG variables. The variables are defined as follow: QT interval (beginning of QRS complex to the end of T wave) was measured in all the derivations. This measured QT intervals were corrected by Bazett’s formula and defined as QTc [9] . QTd was defined as the difference between longest QT interval and shortest QT interval.
2.2. Statistics
All data were analysed using the Statistical Package for Social Sciences (SPSS; Chicago, IL, USA) program, version 15 with the assistance of statistics department at Manipal University. To compare the ECG variables in all three situations (no mobile phone nearby, mobile phone switched on but not ringing, mobile phone ringing), statistical analysis of variance (ANOVA) with p < 0.05 was performed.
3. Results
Total 100 (mean age 30.5 ± 5.2 years) healthy human volunteers were included in the study. There were 60 male patients. After examination of 12-lead ECG of all the participants in 3 different conditions, the following results are obtained, shown in Table 1. There is no statistically significance difference (p > 0.05) observed among the groups for various variables like heart rate, QT interval, QTC interval and QTd.
4. Discussion
A large number of experimental studies on healthy human volunteers have been carried out after the published literature which demonstrated the impact of mobile phone on cardiac pacemakers [10] . The public interest towards the harmful health effects of the mobile phone increased when Ozguner et al. demonstrated increase in oxidative stress in rat myocardium upon RF exposure [7] .
Our study showed statistically insignificant difference (p = 0.938) in heart rate. The result of our study was comparable with the result of study carried out by Atlasz et al. which also conclude that there was no significant difference observed between RF (emitted by mobile phone) and sham experimental groups even though the exposure were for the period of 10 min [11] . Tahvanainen et al. has also reported that mobile phone exposure does not acutely change heart rate [12] . However, Braune et al. carried out the study on human volunteer and reported that in response to elevated blood pressure (5 - 10 mm Hg) due to 900 MHz RF exposure, auto-regulatory mechanism become activated. The consequence of activation of this mechanism leads to decrease in heart rate. However, in this study the volunteer were exposed to RF for the period of 35 min [13] .
The change in QTC and QT dispersion in ECG reflect abnormal ventricular repolarization. However, our study showed insignificant difference in QTC and QT dispersion in all three situations (no mobile phone, phone not ringing and phone ringing). The result is similar to that of the study conducted by Tamer et al. [14] .
It is necessary to find out whether the radiofrequencies emitted from mobile phones (on a long term basis) produces or contributes to any other ill effects like cardiovascular disease as there are some studies carried out in animals demonstrated that long term exposure of radiofrequencies (2 hr or 3 hr/day for 8 weeks) lead to decrease in heart rate as well as prolonged QTC interval in albino rats [15] . However, such studies have not been carried out in human.
We also need to analyze if chronic mobile phone use produces slow but consistent changes in repolarization and depolarization variables of the heart along with its nature (induced changes are reversible or irreversible).
5. Conclusion
Our prospective study of 100 healthy volunteers conclude that cellular phones have no significant effect on the measured electrical cardiac activity when the cellular phone is placed in close proximity to the heart-anterior

Table 1. Comparison of heart rate and ECG variables of all the participants in three situations.
1bpm: beats per minute; 2ms: milliseconds; 3QTC: Corrected QT; 4QTd: QT dispersion.
chest wall in normal subjects.