Natural Organic Matter Removal in the Context of the Performance of Drinking Water Treatment Processes—Technical Notes ()

1. Introduction
The health impacts of natural organic matter (NOM) are attributed to its influence on drinking water treatment processes (DWTPs) that are aimed to protect drinking water quality and public health [1] [2] [3]. NOM could touch techniques selected to eliminate or kill pathogenic microorganisms, participate in the generation of disinfection by-products (DBPs) and promote the growth of biofilms in the distribution system [4] [5] [6]. Further, its occurrence could form situations that lead to augmented lead and/or copper levels in treated water that are due to its effect on corrosion [7] [8] [9].
The treatability and reactivity of NOM change considerably throughout the world since each water source has unique characteristics [1] [10] [11]. As NOM is composed of several organic compounds, it cannot be quantified directly [12] [13] [14]. Nevertheless, there are some additional parameters that could be utilized to give a sign of the level and quality (i.e., physicochemical and biodegradability features) of NOM [15] [16] [17]. It is crucial to comprehend differences in NOM levels and quality with a view to choice, design, and run suitable DWTPs [18] [19] [20].
Suggesting an efficient NOM control strategy requires to be founded on an excellent comprehension of [1] [21] [22]: 1) changes in the level and feature of NOM in the source water, comprising those attributed to climate change, landscape changes or source water protection programs [23] [24] [24]; 2) NOM’s effect on DWTPs and the influence of water treatment on NOM, for the full range of water quality conditions [26] [27] [28]; and 3) its possible effects on water quality in the distribution system [29] [30] [31].
Source-specific treatability investigations, comprising bench- and/or pilot-scale testing, are primary to define the most efficient treatment solution(s) to eliminate NOM, reduce its reactivity to produce DBPs, decrease its capability to participate in corrosion, and treat biologically stable water for distribution [1] [32] [33]. The shortage of a source-specific treatability investigation can lead to the adoption of unsuitable treatment, an augmentation in DBP levels after the application of the treatment, or other not planned outcomes [34] [35] [36]. Since water sources or DWTPs could vary over time, it is fundamental to usually observe the level and quality of NOM and to assess its influence on treatment, water quality, and distribution system circumstances [37] [38] [39].
This work aims to provide an insight into the effects of NOM on the global quality of drinking water, comprising its possible impacts on DWTPs and so on the safety of drinking water. It outlines the parameters that touch the level and property of NOM and examines the indexes to adopt when suggesting a NOM control strategy. It also furnishes specific guidance on treatment, monitoring, and water quality goals.
2. Terminological Conventions
Potable water guidelines, standards, and/or guidance from other national and international organizations could differ because of the date of the assessments as well as different policies and approaches [40] [41]. International organizations have not established numerical limits for NOM in drinking water [42] [43]. The United States Environmental Protection Agency’s (U.S. EPA) Rule for disinfectants and Disinfection By-products requires removal of total organic carbon (TOC) by surface water facilities using conventional or lime softening water treatment with levels of TOC above 2 mg/L in their source water [44] [45]. Researchers suggest an optimized NOM removal as a means to minimize biofilm growth in the distribution system [46] [47]. The European Union regulations include TOC as a general water quality indicator; in some jurisdictions, chemical oxygen demand (COD) can be used in place of TOC [48] [49]. In Australia, guidance has been developed for water utilities to help them understand and control the impact of NOM [1] [50] [51].
3. Facts on Natural Organic Matter (NOM) in Drinking Water
3.1. Natural Organic Matter (NOM) Background
Natural organic matter (NOM) is a highly complicated mixture of organic compounds that differ considerably in terms of their physicochemical properties [52] [53] [54]. NOM exists normally in nature; further, it could be the consequence of human activities [55] [56] [57]. NOM is observed in particulate, colloidal and dissolved forms in all ground and surface waters, as well as in rainwater [58] [59] [60]. Besides exposure to NOM in nature is familiar and is related to direct health impacts (such as Blackfoot Disease [5] [61] [62]), the occurrence and features of NOM will possess great effects on DWTPs aimed at protecting public health [63] [64] [65]. NOM has a crucial action in drinking water treatment for several causes [1] [66] [67]. First, NOM could participate indirectly in health effects in several fashions, involving: 1) it provokes a coagulant demand that could conduct to suboptimal coagulation circumstances and decay of pathogen log reduction potential [68] [69] [70]; 2) it induces a chemical disinfectant demand or interferes with ultraviolet (UV) disinfection that could conduct to decay of pathogen log demobilization’s potential [71] [72] [73]; 3) it generates regulated and non-regulated DBPs when it reacts with disinfectants [74] [75] [76]; 4) it promotes the growth of distribution system biofilms that could host pathogens [77] [78] [79] and; 5) it affects corrosion and could form circumstances that lead to elevations in the lead and/or copper levels as a consequence of corrosion of lead- and/or copper-bearing materials (e.g., piping, fittings) [80] [81] [82].
Moreover, DWTPs could be greatly touched by numerous NOM-provoked running problems, namely 1) augmented coagulant injection [83] [84] [85]; 2) bad floc generation or settling [86] [87] [88]; 3) shorter filter run times [89] [90] [91]; 4) more repeated backwashes [92] [93] [94] [95]; 5) augmented sludge formation [96] [97] [98]; 6) decreased hydraulic potential [99] [100] [101]; 7) membrane fouling [102] [103], higher transmembrane pressure and energy consumption, more frequent chemical cleaning and shorter membrane life [104] [105] [106]; and 8) decreased performance of adsorption and ion exchange processes [1] [107] [108].
Further, NOM could conduct to an elevation in consumer complaints since it could participate in the unwanted color, tastes, and odors in drinking water [1] [109] [110].
3.2. Applying Risk Management Approaches
To guarantee water safety, all DWTPs must apply a risk management procedure like the source-to-tap or water safety plan’s procedure [1]. Such procedures need a systematic assessment that implies analyzing the water source, determining the treatment barriers that avert or decrease pollution, underlining the circumstances that could lead to pollution, and defining control actions [111]. Usable monitoring is then determined and usable/management protocols are established (like usual running plans of action, corrective actions, and incident reactions) [47]. Compliance monitoring is defined and other protocols to validate the water safety plan are applied (such as record keeping and consumer satisfaction) [47] [112]. Further, operator training is needed to guarantee the performance of the water safety plan at all conditions [9] [39] [113].
When suggesting and applying a risk management procedure, it is crucial to perceive how NOM could indirectly lead to health effects [1] [114]. NOM could augment prior to variations in turbidity and flow and could stay increased after turbidity and flow have returned to baseline circumstances [115] [116]. Therefore, variations in NOM can go undetected and a deterioration in pathogen log reduction could happen if appropriate monitoring is not used [117] [118] [119]. The aim of the NOM control procedure must be to guarantee protection from pathogens’ hazards at all periods while reducing DBP [120], lead and copper levels, and controlling biofilm generation in the distribution system [121] [122] [123].
3.2.1. Source-Specific Treatability Investigation
Source-specific treatability investigations are proposed to define the most efficacious treatment solution(s) to adequately reduce NOM and to satisfy water quality targets in terms of microbial dangers, DBPs, biological stability, and corrosion control [1] [38] [110]. Evolving a powerful comprehension of the source water is requested to guarantee that a reliable, robust, and resilient treatment procedure is adopted [3] [91] [99]. Source-specific monitoring prior to facility design is required to estimate seasonal changes in NOM and forecast extreme circumstances due to alterations in climate [87] [98] [109]. The treatability study must implicate bench- and/or pilot-scale testing, as well as DBP formation potential trials that are representative of distribution system conditions [28] [79] [83].
3.2.2. Source-Specific Monitoring
The level and quality of NOM must be monitored in raw, treated and distribution system water to guarantee that 1) treatment is regulated for NOM and turbidity removal, 2) DBP, lead and copper levels are as low as reasonably attainable and, 3) biofilm generation is reduced [1] [2] [115].
A source-specific monitoring plan has to be proposed to make certain that DWTPs are aware of 1) raw water quality alterations in terms of NOM level and quality, 2) the influence that NOM has on DWTPs through all water quality circumstances, 3) the effect that treatment has on NOM level and quality and, 4) the influences on distribution water quality [1] [5] [47].
The monitoring plan must be complete and implicate source characterization and operational and compliance monitoring (Table 1) [1] [47]. Further, it has to establish that water quality objectives are invariably satisfied for microorganisms’ dangers, DBPs, biological stability, and corrosion control [29] [31] [32]. If possible, continuous online monitoring must be utilized for highly variable sources (that is to say, those that fluctuate with precipitation/snowmelt events) and critical processes (like coagulation) [55] [93] [108] (Table 2 and Table 3).
![]()
Table 1. Monitoring plan for source water assessments, treatment and operational monitoring, distribution system and suggested parameters and frequencies [1] [2] [47].
![]()
Table 2. Suggested parameters for a comprehensive monitoring program for treating safe drinking water [1] [2] [47].
aDisinfection will decrease UV absorbance without a related decrease in DOC. Therefore, to estimate the treated water SUVA, UV254 must be measured in filtered water pre-disinfectant addition and divided by the treated water DOC, then multiplied by 100. bCOD decreases across each treatment process. Monitoring locations will vary depending on the process trains in place (e.g., flocculation, clarification, and filtration) and the DWTP’s continuous improvement program. cStrict pH control is critical for NOM removal. As alkalinity affects pH control, pH and alkalinity are other important coagulation process monitoring parameters.
![]()
Table 3. Suggested treated water quality targets [1] [2] [47].
aTCU = true color units; bCOD = chemical oxygen demand; cO2 = oxygen; dDOC = dissolved organic carbon; eC = carbon.
4. Definition of Natural Organic Matter (NOM)
NOM is a very complicated mixture of organic compounds differing in polarity, acidity, charge density, and molecular mass [1] [2] [11]. Further, NOM could vary from biodegradable (i.e., labile or semi-labile) to less biodegradable (i.e., recalcitrant or refractory) [2] [11] [108]. Since NOM includes several organic compounds, it could be classified founded on its polarity (i.e., hydrophobic or hydrophilic) and acid/neutral/base features [2] [11] [108]. It is well established that such a procedure leads to six NOM portions, as mentioned in Table 4 [1] [124] [125]. Compound categories inside such portions have also been defined [109]. Compound categories furnish the highest degree of specificity possible, due to the number of compounds that can be existing [2] [11] [108].
The size and shape of NOM are affected by the pH and ionic strength of the water (Figure 1) [1] [20] [40]. At low pH and high ionic strength, NOM could possess a rigid, compact, coil shape [21] [24] [40]. However, at high pH and low ionic strength, it could possess a flexible linear filament shape [13]. Several compounds could show both hydrophobic and hydrophilic features (i.e., amphipathic) and have both negative- and positive-charged functional groups (i.e., amphoteric) [20] [40]. Portions carrying polysaccharides, proteins, and amino sugars possess the highest molecular weights (>10 kDa), while the molecular weights of humic and fulvic acids usually range from 2 kDa to 5 kDa and from 0.5 kDa to 2 kDa, respectively [126]. Further, lignin and tannin derivatives are also abundant in the high to medium molecular weight portions [21] [24] [40]. The smallest NOM portions (<0.5 kDa) have a tendency to be hydrophilic compounds [1]. The most biodegradable portions comprise carbohydrates, amino acids, and proteins; however, the most recalcitrant include lignins, tannins, and terpenoids [21] [24] [40].
![]()
Table 4. NOM portions and compound classes [1] [124] [125].
aHydrophilic acids can also be reported as transphilic NOM [1].
![]()
Figure 1. Coagulation mechanisms for microcystin-LR removal [5].
5. Origins and Presence of Natural Organic Matter (NOM)
The concentration and feature (that is to say, physicochemical and biodegradability characteristics) of NOM could be so changing due to the different hydrological and biogeochemical processes that influence the origins of NOM [40] [127]. Such a phenomenon is in short discussed in the Sections 6 and 7, along with factors that have historically been employed to measure organic matter, including 1) organic color, as a measure of humic and fulvic acids and, 2) organic carbon, the fundamental constituent of NOM [1] [13] [40]. Additional variables that could be utilized to quantify and characterize NOM are reviewed later in this work.
5.1. Origins of Natural Organic Matter (NOM)
There are two natural origins of NOM: allochthonous (i.e., derived from the terrestrial ecosystem) and autochthonous (i.e., derived from the plants and microorganisms growing in the water body) [40] [127]. Further, anthropogenic (human) activities could participate in NOM [1].
Allochthonous NOM is transmitted to aquatic mediums as precipitation moves through the atmosphere and vegetative canopy, infiltrates organic soil layers, and percolates downward through mineral soil layers [1] [40]. Soil humus, plant litter, microbial biomass, and root exudates participate in allochthonous NOM [128]. Allochthonous NOM has a tendency to be naturally hydrophobic [11].
Autochthonous NOM is extracted from phytoplankton, algae, cyanobacteria and macrophytes (i.e., plants attached to or rooted in the substrata of lakes and streams) and can account for 5% - 100% of the DOC concentration, following some circumstances [2] [129]. When allochthonous inputs are increased, like in colored water sources or during precipitation/snowmelt events (i.e., stormflow situations), the fraction of autochthonous NOM has a tendency to be small [1]. On the contrary, when allochthonous inputs are small, like in limpid water sources or during dry periods when there is little runoff, the fraction of autochthonous NOM has a tendency to be elevated [1]. Autochthonous NOM involves a large domain of compounds (mono- and polysaccharides, amino acids, peptides, proteins, nucleic acids, organic acids, lipids, and fatty acids) [130] [131]. DOC is formed via the generation and degradation of the microbial and plant biomass inside water sources [132] [133]. Algal inputs have a tendency to prevail in wide lakes, while macrophytes have a tendency to be the main contributor in small lakes [134]. Algal and cyanobacterial blooms, especially, constitute a source of DOC that could be periodic and intense [12] [16] [29]. Cyanobacterial blooms can be related to more water quality problems because of the possible occurrence of cyanobacterial toxins [57] [91] [109]. Autochthonous NOM has a tendency to be naturally hydrophilic and nitrogen-rich [11].
Anthropogenic origins of NOM comprise septic systems, wastewater treatment and stormwater discharges, agricultural runoff, and industrial discharges. Anthropogenic NOM is noted to be naturally hydrophilic [135] and nitrogen-rich [136]. Watersheds heavily influenced by anthropogenic sources may observe a reduction in TOC or DOC following the amelioration of wastewater or stormwater treatment [1] [137].
Raw water NOM concentrations are regarded as the net influence of hydrological and biogeochemical processes in the watershed or aquifer [138]. The concentration and quality of NOM and thus its treatability (that is to say, the possibility to be eliminated) and reactivity (that is to say, the probability to produce DBPs) change considerably from one source to another, as each water source possesses unique characteristics. For instance, researchers [139] mentioned that two lakes in Nova Scotia only 1 km apart had TOC concentrations of 5.6 and 17.2 mg/L, respectively. In the low TOC lake, the retention time was 1.27 years and organic soils were absent; however, in the high TOC lake, the retention time was 0.35 years and organic soils were present. Longer retention times have a tendency to decrease the DOC concentration. Nevertheless, scientists [140] affirmed that the evapoconcentration of refractory NOM conducted to augmented DOC concentrations with elevating retention time in the sub-humid and semi-arid zones of Alberta. Several researchers have found identical results concerning the variability and uniqueness of NOM for sources in close proximity to each other [1] [137].
As a rule, NOM concentrations are lower in groundwater sources since the organic matter is exposed to adsorption and microbial decomposition phenomena as it is transported across the soil [125] [127]. Nevertheless, such phenomena are restricted by the quantity of biodegradable NOM that is existing. On the contrary, some groundwater flows through aquifer materials that are rich in organic matter leading to high organic carbon concentrations [141] [142]. Following some published documents, organic carbon concentrations in some North American groundwaters range from <0.1 to 22 mg/L [1]. Seasonal variability could happen on a per well basis, so reliance on a single sample to represent groundwater quality may be confusing [1].
The NOM in groundwater has a tendency to be more hydrophilic and recalcitrant naturally [1] [143] and almost as reactive as surface water NOM on an mg/L DOC basis [137] [144]. For instance, researchers [1] noted particular DBP yields of 67 μg trihalomethanes (THMs)/mg DOC and 29 μg haloacectic acids (HAAs)/mg DOC for small groundwater supplies utilizing chlorination. Groundwater sources could possess higher levels of bromide or iodine that could participate in their capacity to produced DBPs [1] [145].
Consequently, localized circumstances possess an extremely crucial contribution in setting the level and quality of NOM [137] [145]. Presence facts discussed above call attention to the variability that could happen, with or without a related alteration in DOC level [1] [146] [147]. Further, the facts illustrate that even if groundwater has a tendency to possess lower NOM levels, some sources could possess increased levels. Therefore, both surface and subsurface sources have to be analyzed.
5.2. Presence of Natural Organic Matter (NOM)
The level and quality (physicochemical and biodegradability characteristics) of NOM could be greatly changing due to the several hydrological and biogeochemical phenomena that export, form, or decompose NOM (Table 5, Table 6) [1].
![]()
Table 5. Presence of natural organic matter (NOM): Level and quality [1].
![]()
Table 6. Dissolved organic carbon (DOC) facts from the health Canada national survey [1].
aMethod detection limit of 0.2 mg/L.
6. Ecological Consequences
Ecological parameters could modify the NOM level and/or the special role of allochthonous, autochthonous, or anthropogenic inputs and that way alter its quality. Such alterations may touch water sources and water treatment techniques (Table 7) [1].
Moreover, investigators have observed that wildfires could lead to long term (>10 years) water quality regression that considerably modifies the level and quality of NOM, and that manner greatly affects water treatment technology [158]. Wildfires are predicted to augment in frequency because of alterations in climate [159]. Additional water quality alterations that are predicted to take place because of a modifying climate and exacerbate NOM-related effects involve augmented water temperature; augmented variability in runoff; and elevated nutrient loading due to extreme runoff events [159]. An elevation in the frequency and severity of algal development and cyanobacterial blooms is forecast to be related to these modifications [1] [159].
7. Effects of Natural Organic Matter (NOM)
Even if NOM has direct health effects (such as Blackfoot Disease [5] [61] [62]), it greatly influences drinking water treatment and could participate in indirect health effects, as well as operational and aesthetic issues [1].
7.1. Indirect Health Effects
7.1.1. Pathogen Log Reductions
As a rule, potable water treatment involves physical removal barriers (such as clarification and filtration) that are assigned pathogen “log removal” credits, and inactivation barriers (primary disinfection) that are assigned “log inactivation” credits. NOM greatly affects both [1].
For chemically founded clarification/filtration techniques, NOM appeals to a coagulant demand that must be overcome before neutrally charged floc particles could generate [1] [11] [108]. Neutrally charged floc particles are required for
![]()
Table 7. Environmental considerations [1].
filters to run correctly and satisfy turbidity requirements for pathogen removal [32] [51] [160]. NOM levels could augment without modification in turbidity or flow and thus may go undetected. In addition, augmented NOM levels prompt the necessity to elevate the coagulant injection to attain neutrally charged floc particles; apart from that, suboptimal coagulation circumstances occur and a reduction in pathogen log removal could happen [1].
Researchers [1] noted Cryptosporidium breakthrough and an elevation in particle counts (2 - 5 μm, 5 - 10 μm and 10 - 15 μm), at a full-scale direct filtration treatment plant, because of augmentation in color in the source water. Several investigators noted the breakthrough of particles > 2 μm at the pilot-scale during periods of increased TOC [161]. Different researches mentioned that Cryptosporidium removal via clarification/filtration could considerably suffer during suboptimal coagulant circumstances (e.g., treatment effectiveness reduced by 2.0 to 3.4 logs as juxtaposed with optimal parameters) [1].
7.1.2. Generation of Disinfection By-Products (DBPs)
Chemical oxidants and disinfectants react with NOM to produce very toxic DBPs [1] [38] [110]. All NOM portions participate in DBP generation, even if certain portions produce more DBPs than other portions [162] [163]. Certain non-regulated DBPs are more cytotoxic and genotoxic than regulated DBPs such as THMs and HAAs [115] [164]. Even if THMs and HAAs could be utilized as measures for the occurrence of additional DBPs, it is crucial to realize that their generation mechanisms and reaction rates are various [1].
7.1.3. Biological Stability
The biological stability of potable water deals with the notion of preserving microbiological water quality from the point of treatment to the point of consumption [1]. Heterotrophic organisms constitute the majority of bacteria in potable water and draw their energy for growth, multiplication, and production of biofilm matrix materials from the decomposition of organic carbon compounds [165]. BOM promotes bacterial growth and biofilm development in the distribution system and premise plumbing that could conduct to problems, which have public health importance. Biofilms give a habitat for the survival of fecal pathogens that may have passed through drinking water treatment barriers or entered the distribution system directly via an integrity breach. Enteric viruses and protozoa could be observed in biofilms; even if such organisms cannot grow in such medium, they can aggregate and be liberated over an extended period [1].
Further, treatment techniques greatly touch the composition and level of organic nutrients. For instance, oxidants like Cl2 and O3 form biodegradable products upon reaction with NOM [90] [137]. Ozone converts NOM to BOM; therefore, biologically active filtration could be needed to stabilize treated water. Moreover, Cl2 could react with the organic matter by that means augmenting the quantities of assimilable organic carbon (AOC) and biodegradable DOC (BDOC) which could worsen the issue of biofilm development in distribution systems [1] [137].
7.1.4. Corrosion Effects
Corrosion is the decay of a material that results from a response with its medium. In potable water distribution systems, corrosion could be provoked by some parameters, comprising the kind of materials utilized in pipes and fittings, the age of the piping and fittings, the stagnation time of the water and the water quality in the system (particularly pH and alkalinity) [47] [53]. Additional potable water quality indicators that could affect corrosion involve temperature, calcium, free chlorine residual, chloramines, chloride, sulfate, and NOM [1].
NOM influences lead and copper corrosion [1] [166]. The impacts of NOM on metal surfaces could be changed. NOM could furnish a protective film, reducing corrosion (particularly over a long timeframe), or it could augment corrosion via a set of pathways 1) NOM can complex with Ca2+ and prohibit protective scale generation or, 2) NOM can run as a food source for microbes that can in turn attack the pipe surface and worsen corrosion [1].
7.2. Running Problems
7.2.1. Coagulation Technique
The coagulation process aims to neutralize the charge (i.e., destabilize) of colloids (comprising microorganisms) at a level that they efficiently assemble through the flocculation stage and are then retained by clarification and/or filtration [2] [7] [93]. Further, coagulation handles retaining NOM via a phase modification that transforms dissolved organic matter (DOM) into particles: either directly by precipitation or by adsorption onto particles formed by the coagulant [11] [12] [17]. When metal coagulants are introduced into the water, chemical responses happen with both particles and NOM. Thus, when a coagulant is injected, the NOM works as a ligand that complexes the positively charged metal ions, exercising a coagulant demand that should be overcome before flocculation could take place [18] [29] [37]. Further, the type of NOM possesses a crucial effect on the coagulation efficiency. For instance, a two-fold augmentation in coagulant injection is requested to coagulate equal mass concentrations of fulvic acids as compared with humic acids [167].
Consequently, coagulation has to be adopted as a “combined” method that considers both NOM and colloids (i.e., turbidity) while having regard to their different coagulation properties [93]. As an illustration, for the pH conditions of most water sources (pH 6 - 8), NOM and colloids carry a negative charge that becomes more negative with augmenting pH. Nevertheless, the negative charge of NOM is usually between 5 - 15 μeq/mg carbon, whilst that of colloids is between 0.05 - 0.5 μeq/mg particle, following the colloid type [1]. Coagulant injection is controlled by NOM, not by turbidity. Turbidity must augment considerably, in the absence of a related NOM elevation, for turbidity to control the coagulant injection. Since NOM levels can quickly augment four- to five-fold during storm events, it is fundamental that DWTPs possess an excellent comprehension of NOM’s influence on coagulant injection [168]. The inability to set the coagulant injection following an alteration in NOM can participate in suboptimal coagulation circumstances and a reduction in pathogen log removal capacity [1].
7.2.2. Membrane Treatment
It is well established that NOM is in charge of membrane fouling that could considerably damage water treatment functioning [1] [102] [103]. As a rule, the hydrophilic neutral fraction of NOM, including polysaccharides and proteins in macromolecular and/or colloidal form (i.e., biopolymers), is in charge of membrane fouling [104] [105] [169]. It is suggested that once fouling is begun by biopolymers, a lowering in electrostatic forces lets hydrophobic NOM to adsorb to the membranes, conducting to more fouling [169]. Scientists [170] affirmed that biopolymer levels around 0.1 mg/L conducted to reversible (i.e., removable by backwashing/air scour) and irreversible (i.e., removable by chemical cleaning) fouling. Researchers [171] noted that fouling by protein-like substances that were not detected in the feed water is related to low levels (detection limit not given).
Additional parameters that influence membrane fouling implicate membrane properties (like the type of membrane, pore size distribution, material, surface charge, hydrophobicity), running circumstances (such as flux, recovery, pretreatment, backwashing, chemical cleaning), and water quality (like pH, ionic strength, concentration, and character of the foulant) [1].
DWTPs must possess an excellent comprehension of the manner by which the NOM in their source water will interact with membranes to avert configurations that cause important fouling [1]. Pretreatment could be requested to decrease biopolymer levels [169]. Pretreatment remains to be adapted to each individual source since effectiveness is source-specific [172]. In order to eliminate aggregated foulant, a program of methodical backwashing and periodic chemical cleaning, employing appropriate foulant-based cleaning chemicals has to be as well applied [1].
7.2.3. Aesthetic Problems
There is no doubt that NOM is in charge of aesthetic troubles like color, taste, and odor [1] [40].
Color provoked by the occurrence of organic matters could take place in both surface and groundwaters [1] [40] [173]. Organic color has a tendency to be formed by the occurrence of humic and fulvic acids, which are black- to yellow-colored substances [40] [124]. Researchers [153] affirmed that 87% of the substances in charge of color in 10 U.S. sources were colloidal and 3.5 - 10 nm in size. Conversely, scientists [174] affirmed that 40% of the compounds in charge of color in seven Finnish sources were <10 kDa (about 1 nm). Highly colored sources have a tendency to possess a higher level of high molecular weight humic acids, which may account for these dissimilarities in size distribution [1]. Fulvic acids constitute a more complicated mixture of low molecular weight compounds that are more hydrophilic than humic acids, and they possess an important effect on the demanded coagulant injection. In addition, a bigger part of fulvic acids is non-coagulable at any pH or coagulant injection [1]. Since humic and fulvic acids are serious DBP precursors, convenient color elimination could be required to satisfy DBP guidelines [108] [145]. For instance, investigators [173] detected THM formation potentials of 250 - 262 μg/L (7-day formation potential test at 20˚C and at around pH 8) for a highly colored groundwater supply with naturally occurring humic and fulvic acids (TOC = 3.93 - 4.70 mg/L; UV absorbance = 0.1829 - 0.1907).
Moreover, tastes and odors could be formed by volatile compounds generated by the microbial biomass (such as actinomycetes, cyanobacteria, fungi), which is washed in from the terrestrial medium or naturally exists in the aquatic system/aquifer [1] [29]. Twenty years ago, scientist [175] specified about 200 volatile organic compounds that generate unwanted tastes and odors. Terpenoids (such as geosmin and 2-methylisoborneol), sulfides and polyunsaturated fatty acids were defined as the most odorous. Different scientists recognized pyrimidines as troublesome [176]. Actinomycetes and fungi could survive in the soft deposits (i.e., accumulated deposits containing organic and inorganic matter) of water distribution systems. Thus, the distribution system can represent a source of taste and odor issues.
In addition, Cl2 responses with NOM can participate in tastes and odors [4] [44] [77]. Especially, nitrogen-rich NOM could produce odorous aldehydes, N-chloraldimines, or nitriles if convenient circumstances subsist with either Cl2 or chloramines [1]. Reaction mechanisms are a function of the selection of disinfectant, disinfectant to amino acid molar ratio, pH, temperature, and reaction time [115] [118]. Amino acids have been recognized as the essential odor-causing precursor and they could be liberated by the lysis of bacterial or algal cells or when proteins are oxidized [1]. Table 8 furnishes the odor threshold levels that have been mentioned in the literature for such compounds. Since nitriles possess much higher odor threshold levels (see Table 8), they are not usually involved in taste and odor events [1]. Further, odor-causing compounds (like terpenoids) and precursors (such as amino acids and proteins) are not efficiently eliminated by traditional treatment [28] [49]. Therefore, additional techniques should be needed to reduce tastes and odors [5] [10] [38]. When odorous compounds are produced, they could remain in the distribution system for more than 500 hours (≈21 days) at 15˚C [1]. Their levels could as well augment in the distribution system because of the liberation of amino acids or peptides from the biofilm [1]. To help DWTPs evaluate and reduce unpleasant tastes and odors, guidance material is obtainable elsewhere [177].
8. Measurement and Characterization
An efficient NOM control procedure requests an excellent comprehension of the origin, presence and change that happens in the source water [178]. DWTPs must possess a very comprehension of 1) their water source and the type and formation of NOM; 2) if NOM changes seasonally or with precipitation/snowmelt events and; 3) how NOM interacts with treatment processes [1].
![]()
Table 8. Odor threshold levels known for NOM-related compounds [1].
8.1. Notices for Measuring Natural Organic Matter (NOM)
Further, TOC measures all organic carbon in a water sample and is the sum of particulate organic carbon and DOC; the latter is practically described as the organic carbon that could pass through a 0.45 μm filter [1] [179]. Because the filter could drain some organic carbon to the sample, it is suggested that at least 50 mL of organic-free water be passed through the filter and filter assembly before filtering the DOC sample [180]. TOC and DOC are quantified indirectly from the CO2 that is generated by UV-catalyzed chemical oxidation or by high-temperature combustion.
Moreover, UV-visible light absorbance at 254, 350, and 440 nm could be linearly related to the DOC level in some freshwater systems. Nevertheless, linear correlations remain less probably to be encountered in sources with strong autochthonous or anthropogenic inputs or where DOC has been largely decomposed by natural UV light (such as long retention time in the lake) [181]. Quantifying UV254 has historically been utilized in the water industry [1]. Samples have to be filtered to retain particle-related alterations in UV absorbance [179]. As a rule, it is mostly tolerated that an alteration in UV absorbance gives an excellent sign of modifications in NOM [182]. Watching online (or daily) UV absorbance furnishes worthy data to engineers on uncertain effects to the coagulant injection, since NOM levels may vary without any detected fluctuation in the flow (or turbidity) [1]. Apart from that, engineers are not conscious of coagulant under-dosing until turbidity spikes are noted in clarified water or filter effluent. It stays fundamental that relationships be proposed on a source-specific basis since the link between NOM and UV absorbance is unique to each source [1]. In several circumstances, it is not easy to determine a relationship between UV254 and DOC [181]. Watching UV-visible light absorbance over a larger domain of wavelengths can be more suitable in numerous situations [182]. On the other hand, the loss of a relationship could be related to the occurrence of NOM that has low UV absorbance (like proteins and sugars) or a high nitrate amount, which may interfere with this quantification. Watching UV-visible light absorbance over a larger domain of wavelengths could as well give a more sophisticated characterization [1].
UV transmittance is a proportional measure of how much light passes through a water sample (at UV254 nm, usually through a 1 cm path length) juxtaposed with how much light passes through pure deionized water (which has a UV transmittance of 100%) [1]. Since UV absorbance and UV transmittance are mathematically related as per Equation (1), no date is lost via selecting one parameter over the other [183]:
(1)
On the other hand, COD helps to provide some evidence of the level of oxidizable organic matter in a water sample [1]. With reference to past events, the COD test method (utilizing potassium dichromate) was not responsive sufficiently for potable water. Methods that are more responsive have since been suggested. Data on the average oxidation state of organic carbon during water treatment could as well be obtained employing a ratio of the molar concentrations of COD and TOC/DOC [1].
With reference to past events, color has been quantified utilizing colorimetric techniques. The occurrence of suspended solids (like clay, iron and manganese oxides) could attribute water the appearance of color and must be retained by filtering the sample through a 0.45 μm filter before measurement of NOM-related organic color (like color-related mainly to the existence of humic and fulvic acids). A filtered sample is practically described as “true color” [179]. Investigators have as well employed visible light absorbance at 420 nm as a measure for organic color [150]. Nevertheless, a 450 - 465 nm wavelength is suggested as a standard spectrophotometric method [179]. The spectrophotometric procedure needs that samples be filtered through a 0.45 μm filter [179]. Juxtaposing true and apparent color findings could let DWTPs decide if color objections are NOM-related. The apparent color applies to unfiltered samples and is a helpful quantification to evaluate the existence of iron and manganese oxides in the distribution system [1].
Quantifying the above-mentioned variables stays easy and quick to do, and numerous tests could be automated. Such measurements could show a modification in water quality is happening; nevertheless, they do not provide data concerning the nature of the NOM. Scientists noted that UV254 divided by the mg/L of DOC might be a useful index of the NOM feature [1]. Later, such a notion became familiar as specific UV absorbance (SUVA). Further, calculating the specific color (true color divided by mg/L DOC) could furnish helpful data [1].
8.2. Natural Organic Matter (NOM) Characterization
8.2.1. Specific Ultraviolet Absorbance (SUVA)
As seen above, the idea of SUVA has been proposed as a working index of NOM nature and coagulation performance for eliminating NOM removal [1] [2]. Table 9 lists the usually adopted relationships between SUVA, NOM composition, UV absorbance, coagulation and potential TOC removal. Evaluating SUVA is broadly utilized to estimate NOM type since it is simple and inexpensive to assess and is an excellent index of alterations in source water quality [2] [135] [137]. As an illustration, investigators [178] followed DOC and UV254 for the White River (Muncie, Indiana) on a daily basis for 22 months. During this time, SUVA varied from 1.40 to 10.51 L/mg∙m. Lower levels were related to periods of low runoff and high algal activity (i.e., hydrophilic, autochthonous NOM); however, high levels were attributed to snowmelt and storm runoff. During a typical rainfall event, SUVA augmented from 2.6 to 4.5 L/mg∙m during 12 h, showing that hydrophobic, allochthonous NOM was being flushed into the source from the terrestrial watershed. Researchers [184] discussed 18 months of surface water data from the U.S. Environmental Protection Agency (U.S. EPA) and discovered an evident relationship between SUVA, source water properties, and the coagulation performance for eliminating organic carbon [1].
![]()
Table 9. Link between SUVA and potential TOC elimination [1].
*The hydrophilic neutral fraction could possess an elevated SUVA that can mislead water treatment designers regarding the potential for organic carbon removal utilizing coagulation.
Broadly, elevated SUVA sources (>4 L/mg∙m) possess NOM that is amenable to coagulation [2]. Nevertheless, the hydrophilic neutral fraction could possess an elevated SUVA that could be misleading with respect to the potential for organic carbon removal employing coagulation [11]. Further, attaining DBP guideline limits will be a function of the raw water NOM level and whether enough quantity of reactive NOM could be eliminated [145]. If the post-coagulation DOC residual stays reactive with respect to DBP generation, additional techniques targeting the elimination of specific NOM portions will be required [1]. Because humic and fulvic acids are big DBP precursors, the appropriate color reduction could be requested to satisfy DBP removal [115]. Low SUVA sources have a tendency to possess NOM that is not amenable to coagulation [1].
8.2.2. Chemical Consumption
Following chemical consumption (like coagulant injection, chlorine demand) and determining the particular injection or demand (i.e., mg/L per mg/L DOC) could aid DWTPs to evaluate alterations in NOM quality. For instance, researchers [185] affirmed that the particular coagulant injection lessened when allochthonous NOM inputs augmented. Likewise, scientists [186] confirmed that the hydrophilic base fraction of NOM forms important chlorine demand, as shown in Table 10. Such a portion includes compounds that are biodegradable (like amino acids). Therefore, eliminating such compounds utilizing biological filtration methods could diminish chlorine demand and DBPs [1]. Investigators [187] alerted that DOC and chlorine demand do not correlate to THMs and HAA5 (i.e., monochloroacetic acid, monobromoacetic acid, dichloroacetic acid, dibromoacetic acid and trichloroacetic acid) because of the existence of some compounds that present important chlorine demand but do not form DBPs. On the other hand, scientists [188] established a linear correlation between THMs
![]()
Table 10. Effect on chlorine demand by NOM portions (+, lowest demand; ++++, highest demand) [1].
and chlorine demand (R2 = 0.94). Further, they observed that chlorine demand may be employed to forecast THM levels in the distribution system when NOM oxidation and halogenation processes dominate, compared with other reactions that consume chorine (like oxidation of inorganic species, photolytic and corrosion processes). Care is suggested when evaluating tendencies related to chlorine demand or specific chlorine demand because reactions are possible to change based on seasonal and weather-related effects, the treatment processes in place, and where chlorine is added [1].
9. Treatment and Distribution System Notices
The source-to-tap or water safety plan’s approach, which involves the accurate choice of the highest quality water source and source water protection, stays an admitted approach to manage risks to drinking water safety [1]. In order to define the most convenient treatment solutions for the full range of water quality conditions, source-specific treatability studies, comprising bench- and/or pilot-scale testing, have to be performed.
Temporal alterations in the level and type of NOM could possess a considerable impact on the choice, design, and application of water treatment processes [47]. Indeed, DWTPs have to merge hazards that are affected by changes in climate (like algal blooms, drought, fire, and flood) into the procedure to maximize the reliability, robustness, and resilience of their systems [1].
9.1. Selection of Convenient Treatment
With a view to suitably choice, design, and run DWTPs, a comprehension of the changes in the level and type of NOM is obligatory―for the full range of circumstances faced over the year, for both surface and groundwater sources [47]. To define the most convenient treatment techniques, DWTPs have to understand the following [1]: 1) the origin, occurrence, and fluctuations in NOM; 2) interactions with other water constituents (like enhanced reactivity due to bromide); 3) interactions with chemicals injected during treatment (NOM provokes a disinfectant and coagulant demand that should be overcome to guarantee microbiologically safe potable water); 4) interactions with unit processes (NOM fouls adsorbents and membranes) and; 5) effects on distribution system water quality.
9.2. Treatment Options
Numerous treatment solutions are obtainable to eliminate NOM. Optimized coagulation remains the most frequently utilized technique since it is efficient in most implementations [108]. Nevertheless, its applicability has to be cautiously examined on a source-specific basis since coagulation could only retain some NOM parts; the residual parts (those not eliminated by coagulation) can react with disinfectants such that DBP guidelines are not attained [2]. For instance, allochthonous NOM has a tendency to be hydrophobic in nature and is usually amenable to coagulation; however, hydrophilic NOM has a tendency to be harder to remove [11] [178]. De facto, for sources high in hydrophilic neutral NOM, coagulation will be inefficient [1]. Therefore, it is so crucial that jar testing and DBP formation potential testing be realized to define the applicability of optimized coagulation for NOM elimination [29]. Further or mohair treatment solutions involve nanofiltration, ion exchange, granular activated carbon (GAC) or powdered activated carbon (PAC), biological filtration, and oxidation processes [26] [89] [145].
Treatment solutions and their noted performance are widely discussed in the literature [1]. Findings establish that NOM elimination could be very changing. More detailed data concerning treatment is obtainable in several references [2] [91].
9.2.1. Optimized Coagulation
Coagulation is a complicated chemical method that could be optimized for both NOM and turbidity removal [108]. Coagulation implicates two essential routes: the first one is composed of charge neutralization and the generation of insoluble precipitates; the second one includes adsorption onto aluminum or ferric hydroxide floc (i.e., sweep coagulation) [8]. Each route is endorsed by some running circumstances linked to pH and coagulant injection [2]. As pH augments, NOM becomes increasingly negatively charged; however, coagulant hydrolysis products with lower positive charge prevail. Consequently, at pH > 7 a four-fold augmentation in the coagulant dosage is needed to beat NOM’s negative charge juxtaposed with that requested at pH 5.5 [1]. Above pH 7, NOM reduction is inferior [2]. Physical parameters (like mixing of the coagulant and mixing circumstances in the flocculator) could touch floc production. Usually, coagulation chemistry dominates the phenomenon [2].
Selecting a coagulant is a function of the properties of the water to be treated. Obtainable coagulant selections (like aluminum- and ferric-based coagulants, inorganic polymer flocculants, organic polyelectrolytes, composite coagulants, and novel coagulants) are examined elsewhere [1]. Several coagulants furnish a broader operational window in matter pH; however, it is remarkable that for all metal coagulants, the pH of minimum solubility augments as temperature decreases [1]. For alum, optimum performance usually happens at pH values near to the pH of minimum solubility (i.e., 6.5 - 6.7 at 4˚C and 6.0 - 6.2 at 20˚C) [189]. Because the pH of minimum solubility is bigger at lower temperatures, a greater coagulant dosage could be required to beat the more negative charge on NOM with the lower positive charge on coagulant hydrolysis products, as mentioned previously. Rigorous pH control is needed for optimum coagulation; indeed, pH has to be maintained constant from coagulant introduction to after filtration to efficiently retain floc particles. Even a small pH alteration could liberate NOM that was already combined into flocs [2]. Jar testing remains requested to optimize coagulant choice [27].
Moreover, NOM dictates the size, structure, and strength of the flocs, controlling both the extent and the rate of the clarification or filtration processes [155]. Numerous investigations have established that low-density NOM flocs are more susceptible to flotation than to sedimentation [1].
The charge-driven type of NOM coagulation implies that electrophoretic monitoring is suitable [7]. In any other way, engineers are not well informed of coagulant under-dosing until spikes in settled water or filter effluent turbidity are detected [1] [145]. If possible, the raw water has to be constantly watched to optimize the coagulant injection [145] [160]. Online watching instruments for NOM comprise TOC, DOC, UV absorbance, and COD; for particle destabilization, they involve zeta potential or streaming current [18]. Maximum NOM eliminations have been reached when the coagulant particle charge is near neutral as detected by zeta potential or streaming current [18]. Negligence to regulate the coagulant injection following a variation in NOM could participate in suboptimal coagulation circumstances and a diminution in pathogen log removal’s capacity [2] [29].
Table 11 sums the TOC compliance monitoring data published by the U.S. EPA [190] as part of its third Six-Year Review. The data report the TOC elimination (in percent) obtained at traditional surface DWTPs as a function of the influent water quality matrix established by the Disinfectants/DBP Rule. As a rule, the U.S. EPA affirmed that regulated DWTPs are reaching higher reductions than mandated, even if several DWTPs have not been apt to attain reduction requirements. The report warned that the data analysis could not decide which DWTPs are permitted to determine alternative performance criteria or which may have treated water TOC less than 2 mg/L [1] [190].
![]()
Table 11. TOC eliminations noted from U.S. EPA compliance monitoring data (2006-2011) [1] [190].
aMean TOC removal; bMedian TOC removal.
More details may be found elsewhere [1] [2].
9.2.2. Membrane Filtration
Presently, four sorts of pressure-driven membranes are utilized in potable water treatment: microfiltration (MF), ultrafiltration (UF), nanofiltration (NF) and reverse osmosis (RO) [105]. Usually, membranes are categorized by the kind of substances they retain, working pressure, and pore size or molecular weight and cutoff (MWCO) [102]. MF and UF are referred to as low-pressure membranes and are utilized for particle/pathogen removal. The preponderant elimination route is straining or size exclusion. NF and RO are referred to as high-pressure membranes and are employed for retaining NOM and inorganics (like sodium, chloride, calcium, magnesium) [56] [106]. The preponderant reduction route is dissimilarities in the solubility or diffusivity [1] [123].
The size distribution of NOM changes between sources; however, commonly, over 50% of NOM molecules possess a molecular weight of <1 kDa and 80% possess a molecular weight of <10 kDa [1]. Thus, a tight NF membrane is needed to retain the majority of DBP precursors, as shown in Figure 2. Researches show that the optimum MWCO for NOM retention is 0.2 - 0.3 kDa [1].
Figure 2 depicts that MF membranes could not retain any NOM parts other than biopolymers. UF membranes can retain some NOM, as illustrated in Figure 2; however, DBP formation potential could not reduce suitably. For instance, researchers [1] mentioned a global DOC retention of 66% for full-scale UF membranes (absolute pore size = 0.01 μm). THM and HAA formation potentials diminished by 54% and 77%, respectively; however, both of them stayed elevated at 200 μg/L and 80 μg/L, respectively (test conditions: chlorine 1.0 ± 0.4 mg/L at room temperature for 24 h). Scientists [1] obtained color retentions of >85% for 27 full-scale NF membrane plants in Norway (raw water’s color = 35 - 50 mg Pt/L; MWCO = 1 - 2 kDa).
![]()
Figure 2. Natural organic matter (NOM) parts retained by membrane processes [1].
9.2.3. Activated Carbon
Activated carbon is an absorbent material that furnishes a surface on which ions or molecules in the raw water could concentrate [1]. It could be used in two fashions: slurry implementations employing PAC or fixed bed reactors with GAC [177]. The reduction routes implicate adsorption of DOM onto PAC or GAC, as well as biodecomposition of BOM in GAC fixed bed reactors if an active biofilm produces. Researchers [1] observed that biofilms could generate in GAC macropores even in the existence of chlorine.
The first application of PAC and GAC in water treatment is to retain micropollutants as well as taste- and odor-causing substances [1]. Employing PAC presents the merit of furnishing virgin carbon when needed (such as during the taste and odor season). GAC fixed bed devices are run identically to traditional rapid rate filters; thus, the GAC features (like type, particle size, reactivation technique) and running circumstances (such as filter velocity, empty bed contact time, backwashing regime, filter run time) touch their efficacy.
The huge specific surface area and well-developed porous structure of GAC could give high sorption capacity for organic compounds [1]. Nevertheless, GAC has not been largely utilized as a first NOM control strategy since the adsorption capacity of GAC has a tendency to be rapidly depleted (in the order of months) and regeneration could be expensive [1]. As an illustration, the U.S. EPA [190] mentions a 120-day reactivation frequency for systems with TOC of <6 mg/L utilizing an empty bed contact time of 10 min. Eliminating high molecular weight hydrophobic NOM by traditional treatment techniques could greatly elevate the working life of GAC [191]. Further, once the adsorption capacity is depleted, GAC could persist to retain NOM via the biodegradation route, although at lower efficacies [1].
Consequently, combining PAC or GAC as a supplementary technique could ameliorate NOM elimination [177]. For PAC, the dose and contact time are fundamental parameters. Findings for two full-scale traditional DWTPs (both utilizing alum coagulation) are mentioned in the literature [1]. In the first one, a PAC dosage of 150 mg/L ameliorated DOC reduction by 20% and THM precursors by 80% [192]. In the last one, a PAC dosage of 11 mg/L increased DOC reduction by 7% but attained no amelioration in the elimination of THM precursors [1]. Jar testing is advised to optimize the PAC sort, dose, and contact time. For GAC, investigations show that the pore volume has to be in a size range that matches the source-specific NOM for GAC to be efficient [191]. As mentioned by scientists [191], the surface area and total pore volume are not sufficient criteria for choosing a GAC for NOM reduction, since such factors do not give data concerning the accessible pore region. Karanfil et al. [191] proposed that DWTPs demand detailed data concerning the pore size distribution and the pH of the point of zero charge for candidate GACs. Rapid small-scale column trials have to be performed to juxtapose the efficiency of alternative GACs, especially for low SUVA sources [191]. Further, the abrasion of GAC particles has to be taken into account, because abrasion could conduct to the lack of GAC material and stratification inside the bed, both of which are unwanted [1].
DWTPs that employ activated carbon for eliminating pesticides or different trace contaminants have to be conscious that NOM competes for adsorption sites and could reduce technique effectiveness. Pretreatment could be needed for reducing NOM, to guarantee that the technology stays economical for its wanted aim [1].
9.2.4. Biological Treatment
Biological treatment focuses on eliminating the BOM portion that promotes biofilm growth in the distribution system and augments chlorine demand [1]. Thus, the performance of biological treatment is a function of the quantity of BOM that is existing in the water, the microbial community consuming the BOM, and the temperature [54] [104]. Recalcitrant or refractory NOM is improbable to be retained by biological techniques unless it is oxidized to convert it into BOM. As a rule, biological treatment ameliorates the biological stability of the water and reduces DBP levels, as well as tastes and odors [1].
The principal biological treatment techniques for potable water involve riverbank filtration, rapid granular media filtration without the maintenance of a disinfectant residual across the bed, and slow sand filtration [1].
More details may be found elsewhere [1].
9.2.5. Oxidation Processes
Oxidation processes comprise ozone [90], chlorine dioxide [4] [77], and advanced oxidation processes (AOPs) like ozone/UV [26], ozone/H2O2 [84], UV/H2O2 [86] [101], and Fenton’s reaction [78] [89]. Following usual water treatment cases, oxidation processes convert the type of organics rather than eliminate bulk NOM [78] [89]. Therefore, oxidation processes are commonly utilized for killing pathogens, taste and odor control, and decomposition of target organic pollutants. Further, O3 and ClO2 have a tendency to force NOM less responsive with Cl2, which usually leads to reductions of THMs and tri-HAAs; nevertheless, several DBPs could augment like halonitromethanes and haloketones [1]. Ostensibly, AOPs could eliminate a set of NOM; however, they could as well augment the generation of DBPs and dichloroacetic acid (DCAA) especially [193] [194] [195]. Dissimilarities between DCAA and trichloroacetic acid (TCAA) generation were affirmed [1]. In situations designated by negative values, an elevation in DBPs happened because of treatment. Therefore, researchers [1] suggested an accurate estimation of oxidation processes when they are applied for DBP control. Because oxidative processes may lead to the removal of numerous DBPs while augmenting others, mitigative precautions have a tendency to concentrate primarily on reducing DBP production by maximizing NOM elimination [177]. Consequently, employing mohair disinfectants to decrease DBP generation has to be adopted carefully [5] [10] [38].
DWTPs have to be conscious that all oxidants, comprising Cl2, form biodegradable products upon reaction with NOM [4] [44] [77]. Therefore, biologically active filtration could be needed to stabilize treated water. Further, DWTPs have to be up to date that all oxidants decrease UV absorbance, which influences SUVA without a related diminution in the NOM level. Consequently, it remains crucial to adopt suitable sampling sites when measuring UV absorbance to determine SUVA [1].
9.3. Distribution System
The BOM (biodegradable part of NOM) influences distribution system water quality via furnishing a source of nutrients that participates in bacterial regrowth and biofilm development. Biofilms could give a habitat for the survival of pathogens of fecal origin that may have passed across drinking water treatment barriers. Opportunistic premise plumbing pathogens (OPPPs) like Legionella and non-tuberculous mycobacteria (e.g., Mycobacterium avium, Mycobacterium intracellulare) are as frequently observed in biofilms of piped drinking water supplies [1]. The chance for the multiplication of OPPPs in the distribution system and plumbing system biofilms is of augmenting worry to the DWTPs. For instance, in the United States, the most frequently noted reason of eruptions related to potable water is Legionella linked to building plumbing systems (largely in hospitals or health care facilities that fall outside the jurisdiction of water utilities) [1].
More details may be found elsewhere [1].
10. Conclusions
From this review, the following observations and conclusions arose:
1) DWTPs have to compile water quality data to regulate their water treatment techniques, satisfy regulatory requirements associated with DBPs, lead and copper, as well as lessen biofilm generation. Site-specific situations and treatment targets affect monitoring requirements, comprising, but are not limited to parameter selection, analysis method, and frequency. The monitoring frequency is frequently founded on source variability and/or the critical nature of treatment technology. Highly variable water sources and critical processes have to, therefore, be controlled on a more frequent basis [1].
2) Raw water control has to be performed to distinguish the source and better grasp the circumstances that conduct to alterations in the levels and/or type of NOM (e.g., precipitation/snowmelt events, algal blooms, drought, fire), and the parameters that ameliorate the reactivity of NOM to produce DBPs (e.g., reaction parameters, water age, inorganic compounds such as ammonia, bromide, iodide, and sulfur). Continuing running control and treatment regulation will assist to guarantee that DWTPs conveniently eliminate NOM to satisfy linked water quality aims concerning microbial dangers, DBPs, biological stability, and corrosion control. The compiled data have to be examined to evaluate the following [1]:
If, and how, source water quality is varying (like true color, UV absorbance, DOC, SUVA);
If a correlation exists between raw water DOC and other surrogates are utilized to quantify NOM level (like true color, UV absorbance);
How NOM is affecting water treatment techniques (like chemical utilization and specific chemical injection/demand) and if control restrictions have to be defined;
How the treatment is influencing NOM (such as remaining NOM level, alteration in SUVA, specific DBP yields, specific color) and if control restrictions have to be defined;
Distribution system effects (like DBP levels, lead/copper levels);
Biological stability (like variability in disinfectant residual, biofilm formation rate, modifications in corrosion rates); and
If a correlation exists between treated water NOM surrogates (such as DOC, true color, UV absorbance, COD) and distribution system water quality (like DBPs, specific DBP yields, lead, copper, biological stability).
3) A permanent amelioration action has to be implemented to guarantee water treatment is regulated to attain water quality targets and increase public health safeguards for the full range of water quality circumstances. Treated water quality objectives will be source- and system-specific for the next causes [1]:
Numerous sources could possess a higher specific DBP yield (like μg DBP/mg DOC) than other sources. This could be related to source-specific dissimilarities in NOM type (such as some NOM portions produce more DBPs than others do) or the occurrence of inorganic compounds that augment DBP formation rates (like ammonia, bromide, iodide, and sulfur). Sources with higher specific DBP yields are classified as more “reactive”.
Some systems have extensive distribution systems. A distribution system with a residence time of 7 days and a temperature of >15˚C will need a different level of NOM removal to meet DBP guidelines than one with a residence time of 3 days and a temperature of <15˚C.
4) For more responsive sources and extensive distribution systems, water has to be treated to more strict requirements, since there is a bigger probability for DBP generation. Less responsive sources have more flexibility concerning upper control limits for most of the parameters, with the following exceptions [1]:
COD: as COD quantifies oxidizable organic matter, a highly responsive source with 2 mg/L TOC and a less responsive source with 4 mg/L TOC could possess comparable COD levels.
DOC for biological stability: a DOC of <1.8 mg/L is proposed to minimize the biofilm generation rate and disinfectant variability regardless of source water quality or secondary disinfectant used for residual control (free chlorine).
Acknowledgements
The Research Deanship of University of Ha’il, Saudi Arabia, through the Project RG-19 1190, has funded this research.