Engineering

Volume 5, Issue 1 (January 2013)

ISSN Print: 1947-3931   ISSN Online: 1947-394X

Google-based Impact Factor: 1.09  Citations  

Mechanical Stress Analysis of a 600MW Supercritical Boiler Superheater Outlet Header

HTML  Download Download as PDF (Size: 146KB)  PP. 66-68  
DOI: 10.4236/eng.2013.51B012    6,852 Downloads   9,109 Views  Citations

ABSTRACT

The mechanical stress distribution and the stress concentrations of the superheater outlet header of a 600MW supercritical boiler were analyzed by the finite element method. The results showed that the stress concentrated at the inside conjunction area between the pipe and the header cylinder , and the value of the maximum mechanical stress concentration factor is 2.51.

Share and Cite:

Li, D. , Fu, Z. , Zhang, Q. and He, T. (2013) Mechanical Stress Analysis of a 600MW Supercritical Boiler Superheater Outlet Header. Engineering, 5, 66-68. doi: 10.4236/eng.2013.51B012.

Copyright © 2025 by authors and Scientific Research Publishing Inc.

Creative Commons License