Materials Sciences and Applications

Volume 3, Issue 4 (April 2012)

ISSN Print: 2153-117X   ISSN Online: 2153-1188

Google-based Impact Factor: 1.34  Citations  

A Model for the Characterization and Selection of Beeswaxes for Use as Base Substitute Tissue in Photon Teletherapy

HTML  Download Download as PDF (Size: 915KB)  PP. 218-223  
DOI: 10.4236/msa.2012.34032    5,817 Downloads   8,429 Views  Citations

ABSTRACT

This paper presents a model for the characterization and selection of beeswaxes for use as base substitute tissue for the manufacture of objects suitable for external radiotherapy using megavoltage photon beams. The model of characterization was divided into three distinct stages: 1) verification of aspects related to the origin of the beeswax, the bee species, the flora in the vicinity of the beehives and procedures to detect adulterations; 2) evaluation of physical and chemical properties; and 3) evaluation of beam attenuation capacity. The chemical composition of the beeswax evaluated in this study was similar to other simulators commonly used in radiotherapy. The behavior of the mass attenuation coefficient in the radiotherapy energy range was comparable to other simulators. The proposed model is efficient and enables convenient assessment of the use of any particular beeswax as a base substitute tissue for radiotherapy.

Share and Cite:

R. Vidal and D. Souza, "A Model for the Characterization and Selection of Beeswaxes for Use as Base Substitute Tissue in Photon Teletherapy," Materials Sciences and Applications, Vol. 3 No. 4, 2012, pp. 218-223. doi: 10.4236/msa.2012.34032.

Cited by

[1] Karakterisasi Bolus Berbahan Campuran Beeswax dan Petroleum Jelly Menggunakan Berkas Elektron Pada Energi 6 MeV dan 9 MeV
Jurnal Teori dan …, 2024
[2] Tissue Substitute Materials for the Human Colorectal Cancer Tissue.
umo, JA Obu, NO Chiaghanam… - … -I Fīzīk-I Pizishkī-i Īrān, 2023
[3] Analisis Dosis Serap Bolus Berbahan Campuran Beeswax dan Petroleum Jelly Dalam Radioterapi Menggunakan Elektron 6 MeV Pada LINAC
Jurnal Fisika Unand, 2022
[4] Fabrication of Alternative Bolus for Cobalt-60 Teletherapy Using Two Locally Available Materials
2020
[5] Verification of Depth Dose Curves Derived on Beeswax, Paraffin and Water Phantoms Using FLUKA Monte Carlo Code
2020
[6] Estimation of organ absorbed dose in pediatric chest X-ray examination: A phantom study
2020
[7] Beyond Pollination: Honey Bees (Apis mellifera) as Zootherapy Keystone Species
2019
[8] REVIEW OF THE EXTENDED PHENOTYPES OF HONEY BEES (Apis mellifera), AND THEIR IMPACT ON COLONY HEALTH (SOCIAL IMMUNITY) AND HUMAN …
2018
[9] Verification of radiodynamic therapy by medical linear accelerator using a mouse melanoma tumor model
Scientific Reports, 2018
[10] DEVELOPMENT AND CHARACTERIZATION OF A HIGH-ENERGY IN-LINE PHASE CONTRAST TOMOSYNTHESIS PROTOTYPE
2016
[11] Diffusion de la lumière dans les milieux complexes à base de cristaux liquides
2016
[12] Characterization of a high‐energy in‐line phase contrast tomosynthesis prototype
Medical physics, 2015
[13] Characterization of a high-energy in-line phase contrast tomosynthesis prototype
Medical Physics, 2015
[14] ROGÉRIO MATIAS VIDAL DA SILVA
2015
[15] Simulador para estudo avançado da distribuição da dose em bexiga durante procedimentos de braquiterapia ginecológica
2015
[16] Phantom study based on a high-energy in-line phase contrast tomosynthesis prototype
SPIE BiOS. International Society for Optics and Photonics, 2014

Copyright © 2025 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.