Journal of Biomaterials and Nanobiotechnology

Volume 10, Issue 4 (October 2019)

ISSN Print: 2158-7027   ISSN Online: 2158-7043

Google-based Impact Factor: 1.69  Citations  

Characterization of BellaGel SmoothFine® Implant Surfaces and Correlation with Capsular Contracture

HTML  XML Download Download as PDF (Size: 4016KB)  PP. 196-211  
DOI: 10.4236/jbnb.2019.104012    1,439 Downloads   3,218 Views  Citations

ABSTRACT

BellaGel SmoothFine® implant is a novel nanotextured silicone breast implant. The objective of this study was to characterize differences of BellaGel SmoothFine® surfaces with commercial available implant surfaces in terms of texture, topography, and wettability as well as the behavior of capsular contracture. The surface textures of breast implants from two different manufacturers (Hans Biomed and Motiva) were evaluated. The implants utilized in this study were BellaGel Smooth®, BellaGel Textured®, BellaGel SmoothFine® or Motiva SilkSurface®. The shell textures of these implants were characterized using a scanning electron microscopy, three dimensional confocal laser scanning microscope, and contact angle goniometer. Silicone breast implants were emplaced beneath the panniculus carnosus muscle on the dorsum of Sprague Dawley rats and observed for up to 8 weeks postoperative days. The fibrous capsules around silicone implants were explanted for histological examination. BellaGel SmoothFine® exhibits a relatively flat, with little or no depth in the texturing, 5.96 ± 0.41 μm surface roughness, and a contact angle of 103.14 ± 2.06 BellGel SmoothFine® implant resulted in significant decreases in capsule thickness (P < 0.05) and collagen production (P < 0.05) at 8 weeks with respect to the BellaGel Smooth® and BellaGel Textured® implant groups. Significant (P < 0.05) decreases in inducible nitric oxide synthase, an inflammation marker, were observed in the BellGel SmoothFine®. Fibrous tissue formation markers (Vimentin and alpha-smooth muscle actin) were significantly reduced in BellaGel SmoothFine® surfaces versus BellaGel Smooth® surfaces (P < 0.05) or BellaGel Textured® groups (P < 0.05). Overall, these findings suggest that the nanotextured BellaGel SmoothFine® implant is associated with less breast implant derived capsular contracture than other surfaces.

Share and Cite:

Nam, S. , Lee, M. , Shin, B. , Elfeky, B. , U. Lee, Y. , Moon, D. , Seo, D. and Heo, C. (2019) Characterization of BellaGel SmoothFine® Implant Surfaces and Correlation with Capsular Contracture. Journal of Biomaterials and Nanobiotechnology, 10, 196-211. doi: 10.4236/jbnb.2019.104012.

Cited by

[1] A non-manufacturer-sponsored, retrospective study to assess 2-year safety outcomes of the BellaGel® SmoothFine as compared with its competitors in the …
Plos one, 2023
[2] High-Resolution Ultrasound-Assisted Assessment of Preliminary Short-term Safety Outcomes of an Implant-Based Augmentation Mammaplasty Using a …
… Journal Open Forum, 2022
[3] Effect of Breast Silicone Implant Topography on Bacterial Attachment and Growth: An In Vitro Study
in vivo, 2022
[4] Sci Forschen
2022
[5] Impact on capsule formation for three different types of implant surface tomography
Scientific Reports, 2022
[6] Short-term treatment outcomes and safety of two representative brands of the fifth-generation silicone gel-filled breast implants in Korea
2021
[7] Various Properties of Silicone Breast Implant Surfaces and Multimodal Techniques for the Functional Surface Modification
2020
[8] Short-term Safety of a Silicone Gel–filled Breast Implant: A Manufacturer-sponsored, Retrospective Study
2020
[9] Various Properties of Silicone Breast Implant Surfaces Techniques and for Multimodal the Functional Surface Modification
2020

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.