Systematic Analysis of the ArcCheck Diode Arrays for Tomotherapy Delivery Verification

HTML  XML Download Download as PDF (Size: 3030KB)  PP. 218-225  
DOI: 10.4236/ijmpcero.2014.34028    4,166 Downloads   5,246 Views  Citations

ABSTRACT

Objective: The aim of this study was to evaluate the functional characteristics of ArcCheck? array detectors and the application for Tomotherapy IMRT plan verification. Method and Materials: The basic character of the ArcCheck applying on Tomotherapy system was tested. The diode testing procedures included the followings: The short term reproducibility, linearity, dose rate dependence, the profile measurement compared to ion chamber. The effect of insert on gamma passing rate was also studied. A total number of 602 Tomotherapy Delivery Quality Assurance (DQA) plans were retrospectively analyzed to obtain the action limit results with statistical significance evaluation. Results: The short term reproducibility, linearity, dose rate dependence, profile to ion chamber correlation and clinical application were all compared with satisfactory outcome with this device. If anterior diode points were properly calibrated with machine absolute output, then there was no significant difference between the ArcCheck phantom with and without insert on gamma passing rate. The average passing rate was 97.5% and the recommend action level was established at 92% based on the 602 patients’ clinical data with 95% confidence level criteria. Conclusion: This comprehensive study shows that ArcCheck is an accurate and efficient device for quality assurance of Tomotherapy with remarkable consistency of 3D volume analysis of arc therapy.

Share and Cite:

Yue, Q. , Duan, J. , Li, R. and Yang, J. (2014) Systematic Analysis of the ArcCheck Diode Arrays for Tomotherapy Delivery Verification. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 3, 218-225. doi: 10.4236/ijmpcero.2014.34028.

Cited by

[1] O リング型リニアックにおける三次元半導体検出器を用いたガントリ QA の検討
日本放射線技術学会 …, 2022
[2] Analysis of clinical patient-specific pre-treatment quality assurance with the new helical tomotherapy platform, following the AAPM TG-218 report
Radiation …, 2021
[3] Analysis of plan parameters affecting the delivery quality assurance passing rate of the Tomo direct method in Radixact X9
Journal of the Korean …, 2021
[4] Patient QA System Using Delta4 Phantom for Tomotherapy: A Comparative Study with EBT3 Film
2019
[5] 三次元半導体検出器の経時的感度変化の検討
2019
[6] Implementação de um programa de controle da qualidade com um subsídio a um programa de garantia da qualidade em radioterapia com intensidade modulada
2018
[7] Filmless methods for quality assurance of Tomotherapy using Arc CHECK
2017
[8] Filmless methods for quality assurance of Tomotherapy using ArcCHECK
Medical physics, 2016
[9] Gamma-Index Passing Rates in Baseline Plans Measured with a Detector Array
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 2015

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.