Influence of dc Component during Inadvertent Operation of the High Voltage Generator Circuit Breaker during Mis-Synchronization

HTML  Download Download as PDF (Size: 716KB)  PP. 225-235  
DOI: 10.4236/epe.2013.53022    8,045 Downloads   13,314 Views  Citations

ABSTRACT

This paper analyses the synchronization problem of a generator onto power system without satisfying synchronization condition. The main focus of the paper is on the impact of the dc component of the current in the high voltage circuit breaker during its close-open operating cycle. Using real time measurements of currents/voltages and angles during the close-opening cycle of high voltage generator circuit breaker and the impact of the dc component of current in context of interrupting large magnitude of current from the circuit breaker. In addition, the paper describes a study case model and the results of simulations performed using the software EMTP-ATP of an actual incident that occurred during the inadvertent synchronization of a large 339 MW, 24 kV generator to the grid.

Share and Cite:

K. Kadriu, A. Gashi, I. Gashi, A. Hamiti and G. Kabashi, "Influence of dc Component during Inadvertent Operation of the High Voltage Generator Circuit Breaker during Mis-Synchronization," Energy and Power Engineering, Vol. 5 No. 3, 2013, pp. 225-235. doi: 10.4236/epe.2013.53022.

Cited by

[1] Effective Utilization of Parallel-Connected Megawatt Three-Level Back-to-Back Power Converters in Variable Speed Pumped Storage Units
2019
[2] Effective Utilization of Parallel Connected Megawatt Three-Level Back-to-Back Power Converters in Variable Speed Pumped Storage Units
2018
[3] A Review of Power Electronic Converters for Variable Speed Pumped Storage Plants: Configurations, Operational Challenges, and Future Scopes
2018
[4] On line monitoring technology of mechanical characteristics of circuit breaker based on contact stroke measurement
2018
[5] Transient stability investigation on single pole tripping scheme of the 230 kv transmission line in Nam Ngum 2 hydro power project
2017
[6] Analysis of failure of a circuit breaker employed for capacitor switching: A review
2017
[7] DESIGN OF REAL-TIME FUZZY LOGIC PSS BASED ON PMUs FOR DAMPING LOW FREQUENCY OSCILLATIONS
2016
[8] SF_6 断路器中微量水分超标的原因分析及防治措施
自动化应用, 2016
[9] DC Fault Analysis and Protection in MTDC Grid-based Hybrid AC/DC Networks
2016
[10] Analysis of mechanical characteristics force signal of high voltage circuit breaker
2015

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.