ABSTRACT

Filter backprojection is an important method of image reconstruction technique in clinical nuclear medicine imaging. Because of noisy images due to less available photon statistics and different factors associated with imaging system in nuclear medicine tomography, using optimal filter to suppress the noise with keeping the proper signal is one of the significant steps in image reconstruction strategy for clinical use. In this paper, we present the effect of implementation of different filters on the hot region of Carlson phantom SPECT image in reconstruction process. By defining some criteria such as image smoothness and contrast, estimation of spatial resolution and location of hot cylindrical sources and their detectability the best filter with specified parameter have been determined and the results have been interpreted. Results show that the perceived image quality of hot region and also their detectability has been improved when Shepp-Logan and Ram-Lak filters with cut-off frequency of 0.4 has been used.

Share and Cite:

Sadremomtaz, A. and Taherparvar, P. (2013) The influence of filters on the SPECT image of Carlson phantom. Journal of Biomedical Science and Engineering, 6, 291-297. doi: 10.4236/jbise.2013.63037.

Cited by

[1] Fast algorithm for the determination of the optimum filter for bone SPECT image reconstruction
2021
[2] Comparison of Low-Pass Filters for SPECT Imaging
2020
[3] Wiener filter improves diagnostic accuracy of CAD SPECT images—comparison to angiography and CT angiography
2019
[4] Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small …
2019
[5] Effect of ME Collimator Characteristic, Energy Window Width, and Reconstruction Algorithm Selection on Imaging Performance of Yttrium-90: Simulation Study
2019
[6] Filters in Nuclear Medicine
2019
[7] STUDIES OF DIMENSIONAL METROLOGY WITH X-RAY CAT SCAN
2018
[8] Effect of Cut-Off Frequency of Butterworth Filter on Detectability and Contrast of Hot and Cold Regions in Tc-99m SPECT
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 2016
[9] Quantitative and Qualitative Evaluations of Defect Images in Different Regions of Myocardial Phantom under Implementation of Various Filters in SPECT
Indian Journal of Science and Technology, 2015
[10] Filters in 2D and 3D Cardiac SPECT Image Processing
Cardiology research and practice, 2014

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.