Journal of Analytical Sciences, Methods and Instrumentation

Volume 2, Issue 2 (June 2012)

ISSN Print: 2164-2745   ISSN Online: 2164-2753

Google-based Impact Factor: 0.42  Citations  

Optimal Sample Preservation and Analysis of Cr(VI) in Drinking Water Samples by High Resolution Ion Chromatography Followed by Post Column Reaction and UV/Vis Detection

HTML  Download Download as PDF (Size: 460KB)  PP. 74-80  
DOI: 10.4236/jasmi.2012.22014    5,502 Downloads   10,533 Views  Citations

ABSTRACT

A recent study by the Environmental Working Group reported the detection of hexavalent chromium (Cr(VI)) in tap water at 31 out of 35 states investigated in the United States. Even though Cr(III) is an essential element for human diet, Cr(VI) is a potential carcinogen. Previous work has clearly identified a linear trend of increasing risk of lung cancer mortality with increasing cumulative exposure to water soluble Cr(VI). Regardless, Cr(VI) is still not regulated or monitored in drinking water in the U.S. There is an existing method (EPA 218.6) for the analysis of Cr(VI), however, this analytical method does not addresses detailed sample preservation techniques and optimization process to achieve lowest detection limit possible. In this study, five buffer solutions with pH of 9 and above were compared to determine the most suitable buffer to preserve Cr(VI) in drinking water samples for an extended period of time. Results showed that the five buffers responded very differently to Cr(VI)-fortified drinking water. The best preserving reagent was found to be Ammonium Hydroxide + Ammonium Sulfate (pH 9.2) and Sodium Carbonate + Sodium Bicarbonate+ Ammonium Sulfate (pH 9.7), whereas a buffer solution with Sodium Hydroxide + Sodium Carbonate (pH 11.5+) resulted in a poor chromatographic resolution. A controlled study with a fortified Cr(III) at 1 ppb was also conducted to ensure no false positive detection of Cr(VI) due to the potential oxidation of Cr(III) during sample storage. The optimal preserving reagent identified from this study was compatible with the existing EPA method 218.6 using ion chroma-tography followed by post column reaction, with a method quantitation limit of 0.020 ppb and matrix spike recovery of ± 10%.

Share and Cite:

P. Ezebuiro, J. Gandhi, C. Zhang, J. Mathew, M. Ritter and M. Humphrey, "Optimal Sample Preservation and Analysis of Cr(VI) in Drinking Water Samples by High Resolution Ion Chromatography Followed by Post Column Reaction and UV/Vis Detection," Journal of Analytical Sciences, Methods and Instrumentation, Vol. 2 No. 2, 2012, pp. 74-80. doi: 10.4236/jasmi.2012.22014.

Cited by

[1] The role of PKA/PP2B-mediated Drp1 phosphorylation and the subsequent EGFR inhibition in Cr (VI)-induced premature senescence
2021
[2] One-minute highly selective Cr (VI) determination at ultra-trace levels: An ICP-MS method based on the on-line trapping of Cr (III)
2021
[3] Measurement of Chromium Species in Water Samples
Encyclopedia of Water: Science …, 2019
[4] Hexavalent Chromium
Emerging …, 2019 - … Sound Parkway NW, 2019
[5] Chromium Speciation in Water Samples by Loading a New Sulfide-Containing Biodegradable Polymer Adsorbent in Tip of the Syringe System
2019
[6] Electrochemical reduction of hexavalent chromium on titania nanotubes with urea as an anolyte additive
Electrochimica Acta, 2018
[7] Concurrent Removal and Reduction of Cr (VI) by Wool: Short and Long Term Equilibration Studies
American Journal of Analytical Chemistry, 2015

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.