Article citationsMore>>
Caixeta, A.M., Brito, F.S.Jr., Rati, M., Perin, M.A., da Luz, P.L., Ramires, J.A., Ambrose, J.A. and Martinez, E.E. (2000) High versus low-pressure balloon inflation during MultilinkTM stent implantation: Acute and longterm angiographic results. Catheterization & Cardiovascular Interventions, 50, 398-401.
doi:10.1002/1522-726X(200008)50:4<398::AID-CCD5>3.0.CO;2-1
has been cited by the following article:
-
TITLE:
Comparison of pre-dilation with a non-compliant balloon versus a dual wire scoring balloon for coronary stenting
AUTHORS:
Kenji Sadamatsu, Keiki Yoshida, Yuya Yoshidomi, Yasuaki Koga, Kaori Amari, Tomotake Tokunou
KEYWORDS:
Intravascular Ultrasound; Stent; Coronary Artery Disease; Restenosis; Angioplasty
JOURNAL NAME:
World Journal of Cardiovascular Diseases,
Vol.3 No.6,
August
26,
2013
ABSTRACT: Purpose: The aim of this study was to determine the influence of lesion preparation using the dual wire scoring balloon on stent expansion and long-term outcomes. Methods: Forty-six consecutive de novo lesions treated with a single >2.5 mm drug-eluting stent under intravascular ultrasound guidance, using two implantation strategies, were randomly assigned to: 1) pre-dilation with a non-compliant balloon (NC group; n = 23) or 2) pre-dilation with a dual wire scoring balloon (DS group; n = 23). Results: Although the balloon size and the maximal dilation pressure for pre-dilatation was larger (3.33 ± 0.28 vs 3.09 ± 0.33 mm, p = 0.01) and higher (11.6 ± 3.2 vs 8.6 ± 2.7 atm, p