Article citationsMore>>
Abramovitz, M., Adam, M., Boie, Y., Carrière, M., Denis, D., Godbout, C., Lamontagne, S., Rochette, C., Sawyer, N., Tremblay, N.M., Belley, M., Gallant, M., Dufresne, C., Gareau, Y., Ruel, R., Juteau, H., Labelle, M., Ouimet, N. and Metters, K.M. (2000) The Utilization of Recombinant Prostanoid Receptors to Determine the Affinities and Selectivities of Prostaglandins and Related Analogs. Biochimica et Biophysica Acta (BBA)-Molecular and Cell Biology of Lipids, 1483, 285-293.
http://dx.doi.org/10.1016/s1388-1981(99)00164-x
has been cited by the following article:
-
TITLE:
A Polymer Coated Cicaprost-Eluting Stent Increases Neointima Formation and Impairs Vessel Function in the Rabbit Iliac Artery
AUTHORS:
Christopher McCormick, Robert L. Jones, Roger M. Wadsworth, Alexander B. Mullen, Simon Kennedy
KEYWORDS:
Cicaprost, Neointima, Iliac Artery, Endothelium, Drug-Eluting Stent
JOURNAL NAME:
Pharmacology & Pharmacy,
Vol.7 No.6,
June
24,
2016
ABSTRACT: Drug-eluting stents have been successful in reducing in-stent restenosis but are not suitable for all lesion types and have been implicated in causing late stent thrombosis due to incomplete regeneration of the endothelial cell layer. In this study we implanted stents coated with cicaprost, a prostacyclin analogue with a long plasma half-life and antiproliferative effects on vascular smooth muscle cells, into the iliac arteries of rabbits. At 28-day follow-up we compared neointima formation within the stented vessels and vascular function in adjacent vessels, to assess if cicaprost could reduce restenosis without impairing vessel function. Arteries implanted with cicaprost eluting stents had significantly more neointima compared to bare metal stents. In adjacent segments of artery, endothelium-dependent relaxation was impaired by the cicaprost-eluting stent but vasodilation to an endothelium-independent vasodilator was maintained. We conclude that the presence of the polymer and sub-optimal release of cicaprost from the stent may be responsible for the increased neointma and impaired functional recovery of the endothelium observed. Further experiments should be aimed at optimising release of cicaprost and exploring different stent polymer coatings.
Related Articles:
-
Du Thanh Hang, Than Thi Thanh Tra, Le Minh Tuan, Geoffrey Peter Savage
-
Tiama Guy Nicaise Ballet, Kôkôh Rose Effebi, Olga Yolande Aké Ako, Yapo Habib Kpidi, Ossey Bernard Yapo
-
Hervé A. N’cho, Innocent K. Kouame, Kouadio Koff, Lazare K. Kouassı, Séraphin K. Konan, Ruth Baï, Andrei Sandu, Ion Sandu
-
Sarah Tasneem, Lester Lipsky, Reda Ammar, Howard Sholl
-
Jai Dev Chandel, Nand Lal Singh