The Condenser Performance Test and Thermal Performance Analysis of Variable Conditions in TQNPC ()
Qingsen Zhao,
Debing Deng,
Yong Liu,
Wei Chen,
Jiayong Wang,
Jun Xiang,
Song Hu
State Key Laboratory of Coal Combustion, Huazhong University of Science and Technology, Wuhan, China.
The Mal Power Technology Center, Suzhou Nuclear Power Research Institute, Suzhou, China.
DOI: 10.4236/epe.2013.54B108
PDF
HTML
12,807
Downloads
16,229
Views
Citations
Abstract
Condenser is one of the important auxiliary equipments in
nuclear power plants. The thermal efficiency of the entire unit was depended on
the condenser performance. Cleanliness factor and condenser corrected pressure
are the two most important evaluation indexes. The definition and derivation of
these two evaluation indexes were elaborated and clarified in this paper. And
the condenser performance at variable conditions was analyzed. The seawater
temperature, pipe plugging rate and seawater volume rate effect on unit output
was calculated. The calculation method was simple, which can provide reference
guidance for similar power plant.
Share and Cite:
Q. Zhao, D. Deng, Y. Liu, W. Chen, J. Wang, J. Xiang and S. Hu, "The Condenser Performance Test and Thermal Performance Analysis of Variable Conditions in TQNPC,"
Energy and Power Engineering, Vol. 5 No. 4B, 2013, pp. 566-569. doi:
10.4236/epe.2013.54B108.
Conflicts of Interest
The authors declare no conflicts of interest.
References
[1]
|
The People’s Republic of China National Development and Reform Commission. “DL/T1078-2007 Performance Test Code on Steam Surface Condensers operation,” Beijing, 2007.
|
[2]
|
The American Society of Mechanical Engineers, “ASME PTC12.2 1998, Performance Test Code on Steam Surface Condensers,” New York.1998.
|
[3]
|
H. H. Hu, X. P. Wang and Y. Yang, “Test and Correction Method of Condenser Performance in Large Generating Unit,” Power Station Power Station Auxiliaries, No. 12, 2004, pp. 13-17
|
[4]
|
Heat Exchange Institute, “Standards for Steam Surface Condensers,” 9th Edition.Ohio.1995.
|
[5]
|
The People’s Republic of China National Development and Reform Commission, “DL/T932-2005 Guide of Operation and Maintenance for the Condenser and Vacuum System of Power Plant,” Beijing, 2005.
|
[6]
|
D. M. Xu, Y. Ke and S. Y. Wang Shiyong, “The General Calculation Method and Its Application of Turbine Back Pressure,” Thermal Power Engineering, Vol. 25, No. 6, 2010, pp. 605-684
|
[7]
|
Q. S. Zhao, D. B. Deng and Y. Liu, “The Accurate Thermal Performance History Files of Wet Steam Turbine in Nuclear Power Plant,” 2012 Asia-Pacific Power and Energy Engineering Conference, shanghai, 28-31 March 2012.
|