A novel bio-sensor for registration of biting force in occlusally reactive single mandibular implant overdenture

Abstract

Mandibular single denture opposed by maxillary natural dentition showed a great problem. However, mandibular implant overdenture treatment has gained considerable recognition. Ten male patients with complete mandibular edentulous arch and opposing arch have full natural dentition. Patients were divided into two groups. All patients received two endosseous titanium implants. In Group I, patients were rehabilitated with conventional implant retained overdentures. While in Group II, Patients were rehabilitated with occlusal reactive implant overdentures. A Novel proposed biosensor was used to measure the amount of biting force on the implant retained overdenture. Quantitative electromyographic (EMG) signals of the masseter and anterior fibers of temporalis muscles were recorded, filtered and directly interfaced with a computer to represent the data graphically. The mean amplitude (μV), turn, and activity were recorded at the baseline and after three months. The results revealed an increase in the muscle activity in group II after three months as compared to group I. Significant difference in bilateral biting force at the premolar-molar area was found between group I and group II after three months. This study concluded that a resilient implant overdenture denture could be a desirable treatment in mandibular overdenture supported by two implants with resilient attachment and opposing natural dentition due to its easy fabrication and durability in use and increased muscle activity.

Share and Cite:

Banasr, F. and Alammari, M. (2013) A novel bio-sensor for registration of biting force in occlusally reactive single mandibular implant overdenture. Open Journal of Stomatology, 3, 370-378. doi: 10.4236/ojst.2013.37063.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] Rahn, A.O. and Heartwell, C.M. (2000) Text book of complete denture. 5th Edition, PMPH-USA, Philadelphia.
[2] Sharry, J.J. (1974) Complete Denture Prosthodontics. 3rd Edition, McGraw-Hill, New York, 310-311
[3] Anderson, J.N. and Storer, R. (1966) Immediate and Replacements Dentures. Blackwell Scientific Publications, Oxford, 4.
[4] Ellinger C.W., Rayson, J.H. and Henderson, D. (1971) Single complete denture. Journal of Prosthetic Dentistry, 26, 4-10.
http://dx.doi.org/10.1016/0022-3913(71)90023-0
[5] Singh, L.K. and Singh, R. (2013) Single complete denture in mandibular arch opposing natural dentition. A case report. Nitte University Journal of Health Science, 3, 72-75.
[6] Johns, R.B., Jemt, T., Heath, M.R., et al. (1992) A multicenter study of overdentures supported by Branemark implants. The International Journal of Oral & Maxillofacial Implants, 7, 513-522
[7] Mericske-Stern, R.D., Taylor, T.D. and Belser, U. (2000) Management of the edentulous patient. Clinical Oral Implants Research, 11, 108-125.
http://dx.doi.org/10.1034/j.1600-0501.2000.011S1108.x
[8] Trakas, T., Michalakis, K., Kang, K. and Hirayama, H. (2006) Attachment Systems for Implant Retained Overdentures: A literature Review. Implant Dentistry, 15, 24-34. http://dx.doi.org/10.1097/01.id.0000202419.21665.36
[9] Burns, D.R., Unger, J.W., Elswick, R.K. and Giglio, J.A. (1995) Prospective clinical evaluation of mandibular implant overdentures. Part II: Patient satisfaction and preference. Journal of Prosthetic Dentistry, 73, 364-369.
http://dx.doi.org/10.1016/S0022-3913(05)80332-4
[10] Burns, D.R., Unger, J.W., Elswick, R.K. and Beck, D.A. (1995) Prospective clinical evaluation of mandibular implant overdentures. Part I: Retention, stability and tissue response. Journal of Prosthetic Dentistry, 73, 354-363.
http://dx.doi.org/10.1016/S0022-3913(05)80331-2
[11] Zarb, G.A. and Schmitt, A. (1996) The edentulous predicament. I: A prospective study of the effectiveness of implant supportedfixed prostheses. The Journal of the American Dental Association, 127, 59-65.
[12] Winkler, S., Piermatti, J., Rothman, A. and Siamos, G. (2002) An overview of the O-ring implant overdenture attachment: Clinical reports. Journal of Oral Implantology Online, 28, 82-86.
http://dx.doi.org/10.1563/1548-1336(2002)028<0082:AOOTOI>2.3.CO;2
[13] Sohn, B.S., Heo, S.J., Koak, J.Y., Kim, S.K. and Lee, S.Y., (2011) Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses. Journal of Advanced Prosthodontics, 3, 1-9.
[14] Geng, J.P., Tan, K.B. and Liu, G.R. (2001) Application of finite element analysis in implant dentistry: A review of the literature. Journal of Prosthetic Dentistry, 85, 585-598. http://dx.doi.org/10.1067/mpr.2001.115251
[15] Fernandes, C.P., Glantz, P.F., Svensson, S.T. and Bergmark, A. (2003) A novel sensor bite force determination. Dental Materials, 19, 118-126.
http://dx.doi.org/10.1016/S0109-5641(02)00020-9
[16] Ortu G. (2002) A new device for measuring mastication force. Annals of Anatomy, 184, 393-396.
http://dx.doi.org/10.1016/S0940-9602(02)80063-2
[17] Gibbs, C.H., Mahan, P.E., Mauderli, A., Lundeen, H.C. and Walsh, E.K. (1986) Limits of human bite strength. Journal of Prosthetic Dentistry, 56, 226-229.
http://dx.doi.org/10.1016/0022-3913(86)90480-4
[18] Tayel, M., Elaskary, S. and Tamer, N. (2012) A bio-sensory system for increase implant longevity for occlusal analysis. 2nd International Conference on Advances in Computational Tools for Engineering Applications (AC TEA), Beirut, 12-15 December 2012, 7-10.
http://dx.doi.org/10.1109/ICTEA.2012.6462908
[19] Fernandes, C.P., Glantz, P.F., Svensson, S.T. and Bergmark, A. (2003) A novel sensor bite force determination. Dental Materials, 19, 118-126.
http://dx.doi.org/10.1016/S0109-5641(02)00020-9
[20] Bernhausen, E.R. (1979) Resilient material used between the teeth and the denture base: A preliminary report. Journal of Prosthetic Dentistry, 25, 258-264.
http://dx.doi.org/10.1016/0022-3913(71)90186-7
[21] Clancy, E.A., Morin, E.L. and Merletti, R. (2002) Sampling, noise-reduction and amplitude estimation issues in surface electromyography. Journal of Electromyography & Kinesiology, 12, 1-16.
http://dx.doi.org/10.1016/S1050-6411(01)00033-5
[22] Soderberg, G.L. and Knutson, L.M. (2000) Aguide for use and interpretation of kinesiologic electromyographic data. Physical Therapy, 80, 485-498.
[23] Armijo, S. and Magee, D.J. (2007) Electromyograpic activity of the masticatory and cervical muscles during resisted jaw opening movement. Journal of Oral Rehabilitation, 34, 184-94.
http://dx.doi.org/10.1111/j.1365-2842.2006.01664.x
[24] Klemetti, E. (2008) Is there a certain number of implants needed to retain an overdenture? Journal of Oral Rehabilitation, 35, 80-84.
http://dx.doi.org/10.1111/j.1365-2842.2007.01825.x
[25] Bakke, M. (2006) Bite force and occlusion. Seminars in Orthodontics, 12, 120-126.
http://dx.doi.org/10.1053/j.sodo.2006.01.005
[26] Fontijn-Tekamp, F.A., Slagter, A.P., Van’t Hof, Van Der Bilt, A., Writter, D.J., Kalk, W. and Jansen, J.A. (2000) Bitting and chewing in overdentures, full dentures,and natural dentition. Journal of Dental Research, 79, 1519-1524. http://dx.doi.org/10.1177/00220345000790071501
[27] Miyaura, K., Morita, M., Matsuka, Y., Yamashita, A. and Watanabe, T. (2000) Rehabilitation of biting abilities in patients with different types of dental prostheses. Journal of Oral Rehabilitation, 27, 1073-1076.
http://dx.doi.org/10.1046/j.1365-2842.2000.00620.x
[28] Cooper, B.C. (1997) The role of bioelectronic instrumenttation in the documentation and management of temporomandibular disorders. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, 83, 91-100.
http://dx.doi.org/10.1016/S1079-2104(97)90098-6
[29] Lindquist, L., Carlsson, G.E. and Hedegard, B. (1986) Changes in 28 bite force and chewing efficiency after denture treatment in edentulous patients with denture adaptation difficulties. Journal of Oral Rehabilitation, 13, 21-29.
http://dx.doi.org/10.1111/j.1365-2842.1986.tb01552.x
[30] Granick, J. (1975) Reproducility of the electromyogram. Journal of Dental Research, 54, 867-871.
http://dx.doi.org/10.1177/00220345750540042701
[31] Landulpho, A.B., E Silva, W.A.B., E Silva, F.A. and Viti, M. (2004) Electromyographic evaluation of masseter and anterior temporalis muscles in patients with temporomandibular disorders following interocclusal appliance treatment. Journal of Oral Rehabilitation, 31, 95-98.
http://dx.doi.org/10.1046/j.0305-182X.2003.01204.x
[32] Ferrario, V.F., Tartaglia, G.M., Luraghi, F.E. and Sforza, C. (2007) The use of surface electromyography as a tool in differentiating temporomandibular disorders from neck disorders. Manual Therapy, 12, 372-379.
http://dx.doi.org/10.1016/j.math.2006.07.013
[33] Finsterer, J. (2001) EMG-interference pattern analysis. Journal of Electromyography & Kinesiology, 11, 231-246.
http://dx.doi.org/10.1016/S1050-6411(01)00006-2

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.