Safety and Performance of Sirolimus-Eluting Coronary Stent System with Biodegradable Polymer: A Retrospective Analysis in Real-World Patient Population ()
1. Introduction
Cardiovascular disease (CVD) is one of the leading causes of mortality in India [1] . According to the World Health demography 2008 report, global deaths from CVD will extend from 17.1 million in 2004 to 23.4 million in 2030, thus, predetermined CVD is the leading cause of morbidity and mortality worldwide [2] .
Drug eluting stent (DES) has established for the treatment for coronary artery disease (CAD) over the past decade by effectively reducing in-stent restenosis and for the target vessel revascularization (TVR) [3] [4] [5] . Despite that, some adverse events of durable polymers which were used in first-generation DES such as inflammation, vascular hypersensitivity reaction, neo-atherosclerosis, late and very late stent thrombosis (ST) were observed in extensive research [6] [7] [8] . Consequently, several clinical studies have conducted and addressed the above mentioned adverse events through alteration of the stent platforms with blood and tissue compatibility, outer layer of the stent surface, effective anti- restenosis drug, and polymer carriers [5] [9] [10] . Likewise, there remains concern about the inflammatory responses even though some non-biodegradable polymer-coated drug eluting stent pronounced to be safe for long term [11] . Thus, biodegradable polymers are being considered and analysed to acquire and carry drugs. Polymers like poly (lactic acid) (PLA), poly (glycolic acid) and their copolymer, poly (lactic-co-glycolic acid) (PLGA), are most prevalent as they sight characteristics to get completely degraded and metabolized in the body [12] [13] . Moreover, biodegradable polymer would have improved safety and performance of DES as they deliver controlled release of anti-restenotic agent and gradual degradation of coating [14] [15] . Hence, efforts to modify or use different coating materials on the stent surface is one of the efficient ways to alter characteristics of the stent surface and enhance the stent’s biocompatibility, and consequently reduce the episode of thrombosis and restenosis.
Thus, DES such as Metafor™ (CE approved) sirolimus-eluting coronary stent (SES) system (Meril Life Sciences Pvt. Ltd., Vapi, India) has been developed with an objective to reduce the adverse effects of existing DES. In a real-world patient population biodegradable polymer have demonstrated excellent safety and performance in CAD patients as quoted in several studies of DES [16] [17] . The Metafor SES (Meril Life Sciences Pvt. Ltd., Vapi, India) uses L605 cobalt chromium alloy as its stent platform which is coated with a biodegradable and biocompatible polymer to deliver sirolimus. The primary aim of this retrospective study was to evaluate clinical performance of the Metafor SES sirolimus-eluting coronary stent in the treatment of patients enrolled in every day practice at the Apollo Hospitals, Hyderabad, Telangana, India. The primary endpoint was a major adverse cardiac event (MACE) including cardiac death, myocardial infarction (MI), and target lesion revascularisation (TLR). In addition, Stent thrombosis (ST) was analyzed at respective follow-up period.
1.1. Study Design and Patient Population
This was a retrospective, non-randomized, single-center study with the main purpose of evaluating the safety and efficacy of the Metafor sirolimus-eluting stent (SES) implantation for consecutive unselected patients treated in daily practice including those with high-risk characteristics and complex lesions. A total of 127 consecutive patients who underwent PCIs with the use of Metafor SES (Meril Life Sciences Pvt. Ltd., Vapi, India) between February 2012 and February 2015 at the Apollo Hospitals, Hyderabad, India were included in this study.
The inclusion criteria were aged ≥18 years, signs and symptoms of ischemic heart disease and those patients who had at least one Metafor SES implanted. However, patients who refused to provide informed consent were excluded from the study. The study was conducted in accordance with the Helsinki declaration and informed consent was obtained from all patients. This study was approved by Independent Ethics Committee.
1.2. Description of the Study Stent
The Metafor SES is a stainless-steel alloy; CE approved NexGen™, coronary stent. The Metafor SES has an ultrathin cobalt-chromium platform as its stent platform with a unique cell design comprising of an intelligent mix of open and close cells, which has a strut thickness of 65 μm with biodegradable and biocompatible polymer base and a drug load of 1.25 μg sirolimus/mm2.
In Metafor SES, poly-L-lactic (PLL) and poly (lactic-co-glycolic acid) (PLGA) polymers are used to achieve a controlled drug release from drug eluting stent. Metafor SES uses a validated formulation of low dose sirolimus (1.25 μg/mm2) timed to elute in 30 - 40 days from a biodegradable polymer base which degrades simultaneously. The Metafor SES is available in sizes ranging from 8 to 48 mm length and from 2.00 to 4.50 mm diameter.
1.3. Interventional Procedure and Adjunctive Medications
All patients received a loading dose of 325 mg of aspirin and 300 mg clopidogrel or 60 mg of prasugrel or 90 mg of ticagrelor. The procedure was performed according to the standard treatment guidelines of each participating center.
All the patients received dual antiplatelet therapy (DAPT) (aspirin 75 - 300 mg/day indefinitely and clopidogrel 75 mg/day or prasugrel 10 mg/day or ticagrelor 90 mg twice daily for at least 12 months) after the procedure.
1.4. Definitions and Endpoints
The primary endpoint of the study was to determine the rate of MACE; which is defined as the aggregate of cardiac death, MI, and TLR procedure during the follow-up period after the index procedure. Deaths were classified as cardiac or noncardiac. Deaths from uncertain causes were reported as cardiac. The ST was also evaluated in this study which was classified according to the definitions of the Academic Research Consortium [18] . Procedural success was defined as successful stent placement at the desired position with <30% residual stenosis. At follow-up, data were collected relating to current clinical status, any hospitalization after PCI and occurrence of any MACE and ST.
1.5. Statistical Analysis
Categorical data were presented as counts and percentages. Continuous variables were recorded as mean ± standard deviation. The time-to-event curve was presented as per the Kaplan-Meier method. All data were processed using the Statistical Package for Social Sciences, version 15 (SPSS, Chicago, IL, USA). Fisher’s exact testwas used for comparison of MACE events.
2. Results
2.1. Patient Characteristics
The baseline demographics of the patients are edged in Table 1. The analysis
![]()
Table 1. Baseline characteristics of the study population.
*CABG-coronary artery bypass grafting; CAD-coronary artery disease; PCI-percutaneous coronary intervention. †Data are presented as mean ± SD or as number and percentage.
consists of baseline clinical data and follow-up data collected at 3.6 ± 0.6 years mean follow-up period. Apollo hospitals, Hyderabad, India was a site where total of 127 consecutive patients were enrolled and data were collected for analysis. Out of 127 patients, 99 (78%) were males, 58 (45.7%) of patients had diabetes, and 80 (63%) of patients were hypertensive. Among 127 patients, 85 (66.9%) and 38 (29.9%) patients were treated with a diagnosis of stable angina and unstable angina. The mean age was 53.70 ± 8.41 years. In total 9.4% were current smokers whereas, 118 (92.95) patients were having CAD. In addition, history of previous MI, CAD, and prior revascularization procedures occurred in patients with 7.1%, 19.7%, and 17.3% respectively.
2.2. Procedural Characteristics
Metafor SES have treated total of 169 lesions (1.3 stents per lesion). The greater number of patients (38.4%) treated withMetafor SES with lesion length ≥24 mm. In defiance of this, our procedural success was 100%. Single-vessel disease was more frequent (71.7%) in this study revealed in coronary angiography. Also, baseline analysis showed mean percent diameter stenosis of 84.2% ± 10.70% that was treated with Metafor SES stent. The most frequent target vessel was left anterior descending (LAD) artery (37.9%). Specifications of the lesion and procedural characteristics are outlined in Table 2.
2.3. Clinical Outcomes
At the mean follow-up period of 3.6 ± 0.6 years, the primary endpoint occurred
![]()
Table 2. Lesion and procedural characteristics.
in 2 (1.6%) of 127 patients, consisting of 0 (0.0%) cardiac deaths, 0 (0.0%) MI, and 2 (1.6%) TLR. No stent thrombosis was reported. As there were only 2 (1.6%) cases of in-stent restenosis, those went on to require TLR of the right coronary artery, one via PCI and the other via intentional subintimal stenting. The summary of MACE during mean follow-up period of 3.6 ± 0.6 years is outlined in Table 3. Cumulative probability of survival was found to be 98.4% in time-to- event analysis performed by Kaplan-Meier method (Figure 1).
![]()
Table 3. Cumulative clinical events for mean follow-up of 3.6 ± 0.6 years for patients receiving Metafor SES.
*MACE: Major adverse cardiac events (Cardiac death, Myocardial infarction and TLR); TLR: Target lesion revascularization.
![]()
Figure 1. The time-to-event curve at mean follow-up of 3.6 ± 0.6 years by Kaplan Meier method.
3. Discussion
Metafor SES treated a total of 127 patients included in this retrospective study. Construction of Metafor SES consist an ultrathin cobalt-chromium platform and utilizes a hybrid cell design which allows for morphology mediated expansion from the middle to the edges. Asset of such structure is that it allows quick arterial reviving and encouraging procedural outcomes. Results of the current study stated that, in CAD patients during mean follow-up period of 3.6 ± 0.6 years, the Metafor SES exhibited favourable safety and performance in a “real- world” consecutive patient.
Demographic data showed 63% of the patients had hypertension, 45.7% had diabetes, and 66.9% had stable angina plays significant role in real clinical practice and allowing us to evaluate the Metafor SES in a “real-world” patient population. Comprehensive studies report that the presence of a durable polymer with lack of biocompatibility in first-generation DES was associated with inflammation and vascular hypersensitivity reaction delay in re-endothelization, and most importantly, with late and very late stent thrombosis and death [6] [19] . Thus, biodegradable polymers are being considered and investigated in lots of clinical studies to deliver drugs.
Several clinical studies were conducted and compared to analyze the safety and performance of biodegradable polymers. The NEXT trial reported that one-year clinical outcome after implantation of both biolimus-eluting stent and everolimus-eluting stent was phenomenal, with a low rate of TLR and stent thrombosis [20] . Along with NEXT trial, the NOBORI 2 study also concluded good and sustained performance of biodegradable polymers in high-risk patients with indicative comorbidities and/or complex lesions [21] . Moreover, the safety and performance of biodegradable polymers with limus family of DES were firmly accepted in a real-world patient population [17] [20] . In this study, we collected and analyzed the data of Metafor SES with the perspective to evaluate the safety and performance of Metafor SES.
The biodegradable polymer is used in the Metafor SES which reduces the limitations of durable polymers. It was observed that there are lot of factors like stent design, strut thickness, type of antiproliferative agent, drug elution kinetics, elution time, and type of polymer which affect the safety and performance of coronary stent platforms [22] . Likewise, strut thickness is a very influential parameter which matters local inflammation at the lesion site. Two studies confirmed that the rate of restenosis was decreased according to strut thickness. First, in the ISAR-STEREO study, the rate of restenosis was reduced from 25.8% to 15.0% (strut thickness 140 µm Vs. 50 µm). Second, in the ISAR-STEREO-2 trial, two platforms were examined that had identical designs but altered only in strut thickness [23] [24] . The Metafor SES is comprised of thin struts which elevate the device flexibility and device performance. Moreover, The Metafor SES based on a hybrid cell design, which eliminates the classic dog-boning effect and thus, lead to excellent stent positioning, even in complex lesions.
It was observed that there are some restrictions of first-in-man trials which cannot be assumed to “real-world” patients with greater risk or with complex coronary anatomy. A well defined post-market surveillance study can provide significant clinical data of real-world patients treated in a routine clinical practice. Hence, Metafor SES in consecutive patients for the treatment of CAD is carried out as retrospective observational study to evaluate clinical outcomes.
The most convincing clinical results of this retrospective study are 100% procedural success rate; low rates of MACE (1.6%) with no deaths and ST at follow-up. Moreover, MACE occurred in 1.6% of patients consisting of 2 cases of TLR only, which is statistically significant than the 12.9% that was observed in the Endeavor stent (p < 0.001) when compared and the 11.0% that was noted in NOBORI stent (p < 0.001) [25] [26] . Additionally, the SPIRIT II trial observed MACE rates (7.2%) in 223 patients, which also demonstrate significant difference in MACE (1.6%) observed in Metafor SES (p < 0.001) [10] .
Moreover, the major improvements in clinical results were type of polymer and stent platform. When BioMatrix Flex biolimus-eluting stent is compared the strut thickness 112 μm is much higher than 65 μm strut thickness. In this study, the MI (0%) and TLR (1.6%) significantly differ than MI with 7.0% (p < 0.001) and TLR with 7.8% (p < 0.01) of the BioMatrix stent [27] [28] . Hence, the Metafor SES with biodegradable polymer and thinner struts has potential to improve clinical outcomes.
In current study, 45.7% of patients were diabetic and 63% of patients were hypertensive. Even with the complexity of disorders in the present study population, lesser MACE rate (1.6%) at mean follow-up of 3.6 ± 0.6 years demonstrated favourable clinical outcomes of the Metafor SES. Therefore, this observation specifies the excellent performance of the Metaphor SES in a real-world patient population.
4. Study Limitations
There are some limitations of this study, they are: 1) Retrospective and observational design; 2) This was a non-randomised, single-arm study without comparison groups. Therefore, long-term (>5 years) follow-up is essential to assess the factual event rates.
5. Conclusion
In conclusion, the lower episodes of MACE in uncontrolled and real world patient population at long term follow-up clearly represent the prolonged safety and performance of the Metafor SES. Therefore, Metafor stent could be an acceptable substitute even in high risk patients to contemporary DES which are presently available in the market.
Acknowledgements
Authors would like to thank all the patients who were participated in this retrospective study.
Disclosures
The authors declare no conflict of interest.