Open Journal of Fluid Dynamics

Volume 9, Issue 2 (June 2019)

ISSN Print: 2165-3852   ISSN Online: 2165-3860

Google-based Impact Factor: 1.12  Citations  

CFD Assisted Study of Multi-Chapels Greenhouse Vents Openings Effect on Inside Airflow Circulation and Microclimate Patterns

HTML  XML Download Download as PDF (Size: 2291KB)  PP. 119-139  
DOI: 10.4236/ojfd.2019.92009    1,312 Downloads   3,442 Views  Citations

ABSTRACT

The aim of this work is to study and quantify the air mass flow exchanged between inside and outside of the greenhouse, in order to determine the ventilation openings layout and the design effect on greenhouse airflow and microclimate distribution. The study was conducted over a 945 m2 multi-chapels arched greenhouse with a polyethylene cover and has thirteen crop rows oriented from north to south; the greenhouse was equipped with side wall and roof vents openings. A simulation was performed using different arrangements and configurations of ventilation openings with the same wind direction. Numerical simulation has been adopted in three dimensions (CFD), using the Fluent computer code which relies on the resolution of the Navier-Stokes equations. These equations were solved in the presence of the turbulence model (k - ε) and the Boussinesq model equation adopted to incorporate buoyancy forces. The effects of solar and atmospheric radiation were included by solving the radiative transfer equation (RTE), using Discrete Ordinate (DO) model. The effects of the roof openings, the presence of anti-insect screens and crops orientation were investigated and quantified. In a 3-span greenhouse with an anti-aphid in-sect screen in the vent openings, combining roof and sidewall vents gave a ventilation rate per unit opening area that was 1.4 times more than with only side vents. In the latter case, the difference of temperature between the inside and the outside of the greenhouse was greater than 3°C. Numerical simulations with an anti-insect screen having a porosity of 56% showed that the air exchange rate with combined ventilation was reduced by 48%. Finally, the paper focused on the effect of vent arrangement on the efficiency of the ventilation and the distribution of the microclimate inside the greenhouse. Results showed that computed ventilation rates varied from 53.43 to 70.95 kg/s, whereas temperature differences varied from 7.15°C to 10.14°C. This study also showed that other characteristics such as climate heterogeneity must be investigated in order to define the best ventilation configuration.

Share and Cite:

Senhaji, A. , Mouqallid, M. and Majdoubi, H. (2019) CFD Assisted Study of Multi-Chapels Greenhouse Vents Openings Effect on Inside Airflow Circulation and Microclimate Patterns. Open Journal of Fluid Dynamics, 9, 119-139. doi: 10.4236/ojfd.2019.92009.

Cited by

[1] Numerical modelling of an earth-air-tunnel assisted single span saw-tooth greenhouse for tropical climate
International Journal of Thermal …, 2023
[2] Application of green energy in smart rural passive heating: A case study of indoor temperature self-regulating greenhouse of winter in Jinan, China
Energy, 2023
[3] Numerical investigation of greenhouse climate considering external environmental factors and crop position in Sfax central region of Tunisia
Solar Energy, 2023
[4] An Investigation of the Thermal Performance of a Tropical Greenhouse Constructed With an Earth Air Heat Exchanger
Journal of …, 2023
[5] COMPUTATIONAL FLUID DYNAMICS ANALYSIS FOR GREENHOUSE WITH DIFFERENT VENTILATION OPENINGS AND ORIENTATIONS IN SAMSUN …
2022
[6] Three-dimensional numerical simulation of the thermal and aerodynamic behavior of a roof structure built on a slope and used for horticultural production
Comunicata Scientiae, 2021
[7] Innovaciones para la horticultura en ambientes protegidos de zonas tropicales: opción intensificación sostenible de la agricultura familiar en el contexto del …
2021
[8] Implementation of ventilation towers in a greenhouse established in low altitude tropical climate conditions: numerical approach to the behavior of the natural …
2021
[9] Contribution to the Sustainability of Agricultural Production in Greenhouses Built on Slope Soils: A Numerical Study of the Microclimatic Behavior of a Typical …
2021
[10] Two-Dimensional Numerical Study of the Microclimate Generated in Three Screenhouses for the Climatic Conditions of the Colombian Caribbean Two …
2021
[11] Thermo-Environmental Performance of Four Different Shapes of Solar Greenhouse Dryer with Free Convection Operating Principle and No Load on Product
2021
[12] Evaluation of the Microclimate in a Traditional Colombian Greenhouse Used for Cut Flower Production
2021
[13] Analysis of the Thermal Behavior of a New Structure of Protected Agriculture Established in a Region of Tropical Climate Conditions
2021
[14] Technological progresses in modern sustainable greenhouses cultivation as the path towards precision agriculture
2021
[15] Research on the Microclimate of Protected Agriculture Structures Using Numerical Simulation Tools: A Technical and Bibliometric Analysis as a Contribution to the …
Sustainability, 2021
[16] Influence of the Height in a Colombian Multi-Tunnel Greenhouse on Natural Ventilation and Thermal Behavior: Modeling Approach
Velazquez, M Akrami, C Bojacá - Sustainability, 2021
[17] 3D Numerical Analysis of the Natural Ventilation Behavior in a Colombian Greenhouse Established in Warm Climate Conditions
2020
[18] Efficiency of Different Roof Vent Designs on Natural Ventilation of Single-Span Plastic Greenhouse
2019
[19] CFD Simulation of the Increase of the Roof Ventilation Area in a Traditional Colombian Greenhouse: Effect on Air Flow Patterns and Thermal Behavior
2019

Copyright © 2025 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.