Threatened Aortic Injury by Thoracic Pedicle Screw: A Case Report

HTML  XML Download Download as PDF (Size: 1408KB)  PP. 51-56  
DOI: 10.4236/ojo.2018.82007    1,135 Downloads   2,684 Views  

ABSTRACT

Iatrogenic vascular injury during posterior spinal surgery is a rare but potentially serious complication with treatment challenges. We report the case of threatened aortic injury by pedicle screw impingement during posterior fixation of thoracic spine T7 - T8 fracture dislocation. The removal of the conflicting screws was done posteriorly after a visual control of the absence of adventitious break-in by a thoracotomy.

Share and Cite:

Kassé, A. , Diao, S. , Gaye, M. , Sané, J. , Hope, J. , Hemmam, K. , Thiam, B. , Dieng, P. and Sy, M. (2018) Threatened Aortic Injury by Thoracic Pedicle Screw: A Case Report. Open Journal of Orthopedics, 8, 51-56. doi: 10.4236/ojo.2018.82007.