Liquid lead-lithium (Pb-16Li) is of primary interest as one of the candidate materials for tritium breeder, neutron multiplier and coolant fluid in liquid metal blanket concepts relevant to fusion power plants. For an effective and reliable operation of such high temperature liquid metal systems, monitoring and control of critical process parameters is essential. However, limited operational experience coupled with high temperature operating conditions and corrosive nature of Pb-16Li severely limited application of commercially available diagnostic tools. This paper illustrates indigenous calibration test facility designs and experimental methods used to develop non-contact configuration level diagnostics using pulse radar level sensor, wetted configuration pressure diagnostics using diaphragm seal type pressure sensor and bulk temperature diagnostics with temperature profiling for high temperature, high pressure liquid Pb and Pb-16Li applications. Calibration check of these sensors was performed using analytical methods, at temperature between 380°C - 400°C and pressure upto 1 MPa (g). Reliability and performance validation were achieved through long duration testing of sensors in liquid Pb and liquid Pb-16Li environment for over 1000 hour. Estimated deviation for radar level sensor lies within [3.36 mm, +13.64 mm] and the estimated error for pressure sensor lies within 1.1% of calibrated span over the entire test duration. Results obtained and critical observations from these tests are presented in this paper.

Share and Cite:

Saraswat, A. , Sahu, S. , Rao, T. , Prajapati, A. , Verma, S. , Gupta, S. , Kumar, M. , Bhattacharyay, R. and Das, P. (2017) Development of Diagnostics for High-Temperature High-Pressure Liquid Pb-16Li Applications. World Journal of Nuclear Science and Technology, 7, 292-308. doi: 10.4236/wjnst.2017.74023.

Cited by

[1] Design, fabrication and validation of an electrical conductivity principle based two-phase detection sensor array for molten lead (Pb) based heavy metal coolants up to …
Journal of …, 2024
[2] Effect of inlet/outlet height difference on PQ characteristics of an electromagnetic pump for heavy liquid metals
Fusion Engineering and …, 2023
[3] On-Line Measurement of Liquid Metal Level by Change of Static Gas Pressure
Plasma and Fusion Research, 2022
[4] On-Line Measurement of Liquid Metal Level by Change of Static Gas Pressure Ryunosuke NISHIO and Masatoshi KONDO Tokyo Institute of Technology, School of …
Plasma and Fusion Research, 2022
[5] Numerical study of 3D MHD flow of Pb-Li liquid metal in a rectangular U-bend
2021
[6] Design development and testing of mutual inductance type level sensor for molten lead-lithium alloy
2021
[7] Engineering design and development of lead lithium loop for thermo-fluid MHD studies
Fusion Engineering and Design, 2019
[8] Automation and interlock system design for Pb-Li liquid-metal purification experimental facility
2019
[9] Data-acquisition, control & interlock system design for corrosion experiments of IN-RAFM steel with flowing Pb-Li in presence of magnetic field
Fusion Engineering and Design, 2018