International Journal of Medical Physics, Clinical Engineering and Radiation Oncology

Volume 4, Issue 4 (November 2015)

ISSN Print: 2168-5436   ISSN Online: 2168-5444

Google-based Impact Factor: 0.65  Citations  

Comparative Study on the Surface Dose of Some Bolus Materials

HTML  XML Download Download as PDF (Size: 320KB)  PP. 348-352  
DOI: 10.4236/ijmpcero.2015.44041    4,666 Downloads   6,268 Views  Citations

ABSTRACT

In order to investigate the possibility of using different materials as bolus in radiotherapy, five samples denoted by S2 - S6 were prepared and analyzed by comparison with one available commercial bolus denoted by S1. Sample S1 was a thermoplastic material from Qfix; S2 was a moldable silicon rubber (RTV-530 from Prochima); S3 and S4 were obtained by adding micrometric particles of Al and Cu respectively (at the same mass concentration of 5.5%); S5 was another moldable silicon rubber (GSP400 from Prochima) and S6 was a mixture of GSP400 and micrometric particles of Cu (at the mass concentration of 5.5%). The measurements of normalized transmitted dose as a function of sample thickness were performed for all samples (S1 - S6) at two values of electron beam energy (6 and 9 MeV) produced by a linear accelerator VARIAN 2100SC. The results showed that the maximum of the normalized transmitted dose of manufactured samples (S2 - S6) is registered at smaller sample thicknesses than for the analyzed commercial bolus (sample S1). The smallest sample thickness corresponding to normalized maximum point dose is obtained for sample S2 (RTV-530). Measurements performed for electron beam energy of 6 and 9 MeV have proven the possibility of using the manufactured samples as bolus in radiotherapy.

Share and Cite:

Malaescu, I. , Marin, C. and Spunei, M. (2015) Comparative Study on the Surface Dose of Some Bolus Materials. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 4, 348-352. doi: 10.4236/ijmpcero.2015.44041.

Cited by

[1] Investigation of the effect of bolus on skin dose in breast cancer treatment with tomotherapy and LINAC radiotherapy devices
Radiation Physics and …, 2024
[2] The potential of 3-dimensional silicone rubber boluses to improve radiotherapy absorption dosage: A mini-review
AIP Conference …, 2023
[3] Characterization of in-house bolus materials for electron beam radiotherapy
AIP Conference …, 2023
[4] The Impact of In-House Bolus Thickness on The Percentage of Surface Dose for 10 and 12 MeV Electron Beams
Jurnal Penelitian …, 2022
[5] Correlation between anterior–posterior and lateral dimensions with the effective and water-equivalent diameters in axial images from head computed tomography …
Radiation Protection …, 2021
[6] Evaluation of Dosimetric Properties of Handmade Bolus for Megavoltage Electron and Photon Radiation Therapy
2021
[7] Scalp and Cranium Radiation Therapy Using Modulation (SCRUM) and Bolus
2020
[8] Fabrication of Alternative Bolus for Cobalt-60 Teletherapy Using Two Locally Available Materials
2020
[9] Fabrication and Characterization of Bolus Material Using Propylene Glycol for Radiation Therapy
2020
[10] Comparison of Dosimetry Characteristics from Some Bolus Materials for 6 and 10 MV Photons Beam Radiation Therapy
2020
[11] Current-Voltage Response of Cold White LED Strip to Radiotherapeutic Electron and Photon Beams: A Preliminary Study
2020
[12] Dosimetric Characterization of Corn Starch/Polyvinyl Alcohol (PVA) Blend
2020
[13] Dosimetric Characterization of Corn Starch/Polyvinyl Alcohol (PVA) Blend as Potential Radiotherapy Bolus Material
2020
[14] Dosimetric Comparison of Superflab and Specially Prepared Bolus Materials Used in Radiotherapy Practice
2020
[15] A Comparative Study of Dosimetric Characterization of Bolus Based on Natural Rubber (Hevea Brasiliensis) and Clinical Bolus for Therapy with Megavolt Electron …
2020
[16] Comparison of Dose Distribution Effects for Various Bolus Materials in Electron Conformal Radiotherapy
2020
[17] Synthesis and characterization of silicone rubber composite silica as the x-ray shielding
2019
[18] Dosimetry analysis of homemade bolus using propylene glycol for photon MegaVoltage and electron radiation therapy
2019
[19] Dosimetric Characteristics of Transparent Bolus for External Beam Radiotherapy
2019
[20] Validation of the Gel & Wax Boluses and Comparison of their Dosimetric Performance with Virtual Bolus
2019
[21] A systematic review of nutrition recommendation systems: with focus on technical aspects
Journal of biomedical …, 2019
[22] Bolus silicone rubber with 2% silica composite for radiotherapy application
International Journal of Allied Medical Sciences and Clinical Research, 2018
[23] Characteristics of Bolus Using Silicone Rubber with Silica Composites for Electron Beam Radiotherapy
2018
[24] Bolus de compensación personalizado de hidrogel: Caracterización radiológica, uso clínico e incertidumbre de colocación
2017
[25] Journal of Physics and Its Applications
[26] Fabrication of Bolus from Composite of Silicone Rubber (SR)-Copper (Cu) for Radiotherapy Application

Copyright © 2025 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.