ABSTRACT

In this article, the block scheme and metrological characteristics of the State primary standard of the mass (molar) fraction and mass (molar) concentration of the component in the liquid and solid substances and materials based on coulometric titration GET 176-2010 are given. Primary reference materials certified by coulometric titration in the Ural Scientific and Research Institute for Metrology include eight certified reference materials (CRMs) of pure solid substances (mostly salts of sodium or potassium) and one hydrochloric acid solution CRM. The metrological characteristics of these reference materials and the scheme of their application in titrimetric analysis are shown. The expanded uncertainty of the certified value (mass fraction for the solid substances or molar concentration for the solution) is in the range from 0.018% to 0.05%. Information about two primary reference materials of high purity iron and lead nitrate certified by controlled-potential coulometry with expanded uncertainty from 0.04% to 0.07% is also given.

Share and Cite:

Terentiev, G. , Sobina, A. , Shimolin, A. and Zyskin, V. (2014) Application of Coulometric Titration for the Certification of Primary Reference Materials of Pure Substances. American Journal of Analytical Chemistry, 5, 559-565. doi: 10.4236/ajac.2014.59063.

Cited by

[1] DEVELOPMENT OF A COULOMETER AT THE NATIONAL METROLOGY INSTITUTE OF COLOMBIA: DETERMINING THE AMOUNT OF SUBSTANCE …
Osorio, A Castillo, H Torres-Quezada… - Química …, 2024
[2] Specific risks of false decisions in conformity assessment of a substance or material with a mass balance constraint–A case study of potassium iodate
2021
[3] Documentación de métodos de titulación coulométrico a corriente constante para la determinación de la cantidad de sustancia
2020
[4] РАЗРАБОТКА СТАНДАРТНОГО ОБРАЗЦА СОСТАВА 0, 1 М РАСТВОРА БИХРОМАТА КАЛИЯ ГСО 10992-2017
2018
[5] Determination of potassium hydrogen phthalate purity by coulometric titration system: Validation study and uncertainty estimation
2018
[6] Development of a Reference Material for the Composition of 0.1 M Potassium Dichromate Solution. Certified Reference Material GSO 10992-2017
2018
[7] DEVELOPMENT OF A CERTIFIED REFERENCE MATERIAL OF 0.1 M POTASSIUM DICHROMATE SOLUTION GSO 10992-2017
III International Scientific Conference “ …, 2018
[8] Implementation of coulometric titration system at constant current for developing of certified materials as primary standards
Journal of Physics: Conference Series, 2017
[9] Implementation of Coulometric Titration System at Constant Current for Certification of Primary Reference Materials
2017
[10] Potassium iodate purity determination by high precision coulometric titration: New measurement procedure implementation
2017
[11] ОЦЕНИВАНИЕ НЕОПРЕДЕЛЕННОСТИ ИЗМЕРЕНИЙ МАССОВОЙ ДОЛИ ОСНОВНОГО КОМПОНЕНТА МЕТОДАМИ КУЛОНОМЕТРИЧЕСКОГО …
2015
[12] ОЦЕНИВАНИЕ НЕОПРЕДЕЛЕННОСТИ ИЗМЕРЕНИЙ МАССОВОЙ ДОЛИ ОСНОВНОГО КОМПОНЕНТА МЕТОДАМИ КУЛОНОМЕТРИЧЕСКОГО ТИТРОВАНИЯ …
… в измерениях и технологиях»: Сбор-ник …, 2015
[13] Optimization and validation of potassium hydrogen phthalate coulometric titration: A potentially primary method

Copyright © 2025 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.