Energy and Power Engineering

Volume 5, Issue 4 (July 2013)

ISSN Print: 1949-243X   ISSN Online: 1947-3818

Google-based Impact Factor: 1.42  Citations  

Performance Analysis of Induced Draft Fan Driven by Steam Turbine for 1000 MW Power Units

HTML  Download Download as PDF (Size: 174KB)  PP. 1387-1392  
DOI: 10.4236/epe.2013.54B263    9,088 Downloads   11,826 Views  Citations

ABSTRACT

Boiler fan is the main power consumption device in thermal power units and the induced draft fan accounted for the largest proportion. Reducing the energy consumption rate of induced draft fan is the main path to reduce the power consumption rate of thermal power units. The induce fan driven by small turbine is greatly effective for reducing the power consumption rate and the supply coal consumption rate in large thermal power plant. Take 1000 MW power units for example, the selection of steam source for steam turbine were discussed and economic performance of the unit under different steam source was compared in this paper. The result shows that compared with the motor driven method, there is about 1.6 g/kWh decrease in supply coal consumption rate driven by the fourth stage extraction steam; whereas there is about 2.5 g/kWh decrease in supply coal consumption rate driven by the fifth stage extraction steam.

Share and Cite:

J. Deng, F. Liang, Y. Ding, Z. Yang, G. Xu and J. Liu, "Performance Analysis of Induced Draft Fan Driven by Steam Turbine for 1000 MW Power Units," Energy and Power Engineering, Vol. 5 No. 4B, 2013, pp. 1387-1392. doi: 10.4236/epe.2013.54B263.

Cited by

[1] Design and 4E Analysis of a Hybrid Air Supply System for Blast Furnaces Driven by Excess Pressure and Waste Heat Recovery
Journal of Sustainable Metallurgy, 2024
[2] Performance evaluation of a hydrogen-fired combined cycle with water recovery
Case Studies in Thermal Engineering, 2023
[3] Research on Optimal Operation and Safety Control of Thermal Power Unit Auxiliary Machines Under Deep Peaking Conditions
2022 9th International Forum on Electrical Engineering …, 2022
[4] An early fault detection method for induced draft fans based on MSET with informative memory matrix selection
2020
[5] Impact of Auxiliary Equipments’ Consumption on Electricity Generation Cost in Selected Power Plants of Pakistan
Mehran University Research Journal of Engineering & Technology, 2017
[6] 浅析 1000MW 机组汽动引风机汽源方式改造优化
中国新技术新产品, 2016
[7] 600MW 机组汽动引风机系统控制策略优化与仿真
热能动力工程, 2015
[8] 600MW 间接空冷机组汽动引风机汽源切换经济性分析
中国电力, 2015
[9] 600 MW 间接空冷机组汽动引风机汽源切换经济性分析
中国电力, 2015