World Journal of Cardiovascular Diseases

Volume 3, Issue 2 (April 2013)

ISSN Print: 2164-5329   ISSN Online: 2164-5337

Google-based Impact Factor: 0.32  Citations  

Safety and efficacy of amplatzer duct occluder for percutaneous closure of ventricular septal defects with tunnel shape aneurysm: Medium term follow up

HTML  XML Download Download as PDF (Size: 560KB)  PP. 228-233  
DOI: 10.4236/wjcd.2013.32035    4,057 Downloads   6,484 Views  Citations

ABSTRACT

Objectives: Different devices including Amplatzer duct occluder has been used for percutaneous closure of ventricular septal defects. This study reports our medium term follow up of perimembranous and muscular ventricular septal defects with tunnel shape aneurysm closure using the Amplatzer duct occluder. Materials and Methods: From May 2006-December 2012, we used Amplatzer duct occluder in seven ventricular septal defect patients here atHamad General Hospital,Doha,Qatar. There were 4 male and 3 female patients with an age range of 4 - 32 years with a median of 8 years and weight range of 16 - 63 kgwith a median of33 kg. In this group, 6 were perimembranous and 1 muscular and all these ventricular septal defects had a tunnel shape aneurysm. Transesophageal echocardiographic diameter ranged from 4 - 8 mmand Qp/Qs was 1 - 1.6. Angiographically, the diameter on the left ventricular side measured 3.5 - 10 mmand on right ventricular side 2.4 - 5 mm. 8/6 mmAmplatzer duct occluder was used to close these ventricular septal defects. Results: There were no major complications and immediately after the procedure there was no residual shunt in any of these patients and all the patients remained in normal sinus rhythm. One patient was expatriate and no further follow up was available. The rest of the 6 patients had 1 - 80 months with a median of 54 months follow up and none of these patients had any residual shunt and all remained in normal sinus rhythm. Two patients developed trivial aortic valve regurgitation immediate post procedure, one remained unchanged and the 2nd has progressed to mild at this latest follow up. Conclusion: Amplatzer duct occluder is feasible and a safe device for percutaneous closure of selective tunnel shape aneurysmal perimembranous and muscular ventricular septal defects.

Share and Cite:

Dilawar, M. and Ahmad, Z. (2013) Safety and efficacy of amplatzer duct occluder for percutaneous closure of ventricular septal defects with tunnel shape aneurysm: Medium term follow up. World Journal of Cardiovascular Diseases, 3, 228-233. doi: 10.4236/wjcd.2013.32035.

Cited by

[1] Current outlook after 4 years since the beginning of interventional cardiology in congenital heart disease in Chiapas State
Vázquez… - Archivos de Cardiologia …, 2022
[2] Panorama actual a 4 años del inicio de la cardiología intervencionista en cardiopatías congénitas en el Estado de Chiapas
Vázquez… - Archivos de Cardiología …, 2022
[3] Research Article Transcatheter Closure of Perimembranous Ventricular Septal Defects Using Different Generations of Amplatzer Devices: Multicenter …
Vázquez, A El-Sisi, 2020
[4] Transcatheter closure of perimembranous ventricular septal defects using different generations of Amplatzer devices: multicenter experience
2020
[5] Safety and efficacy of transcatheter closure of outlet-type ventricular septal defects in children and adults with Amplatzer Duct Occluder II
2020
[6] Ⅰ 代动脉导管未闭封堵器在封堵膜部室间隔缺损中的应用
心肺血管病杂志, 2015

Copyright © 2025 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.