Patient dose from radiographic rejects/repeats in radiology centers of Urmia University of Medical Sciences, Iran

HTML  Download Download as PDF (Size: 160KB)  PP. 94-100  
DOI: 10.4236/health.2012.42015    13,760 Downloads   22,125 Views  Citations

ABSTRACT

Medical diagnostic X-rays are the largest manmade source of ionizing radiation received by the members of the general public. The aim of this study was to evaluate the radiographic reject/repeat rate and also to determine dose to the patients from radiographic rejects/repeats in radiology centers of Urmia University of Medical Sciences. During a 4 month period the most frequently examinations were chosen in three radiology centers. A form was designed as a reject/repeat analysis form for radiographers to complete each time a film was rejected by radiologists or repeated. The collected data were compiled at the end of each week and entered into a computer for analysis at the end of study. The results of this study showed that highest and lowest repetition rates were for pelvis, 14.01% and upper limb, 4.17%, respectively. The main reasons of repetition of radiographs were due to exposure (54%) and positioning (18%) errors. The average repeat rate in all three hospitals was 7.20%. It was found that human error has important role to repetition of radiographs. It is demonstrated that those patients having repeated radiographs received an average of 3.23 Gy·cm2. Based on the findings of this study it must be remembered that the highest repetition rate was for pelvis. Considering the radiosensitive organs related to pelvis especially in pediatric patients some special considerations must be applied for pelvis examinations.

Share and Cite:

Jabbari, N. , Zeinali, A. and Rahmatnezhad, L. (2012) Patient dose from radiographic rejects/repeats in radiology centers of Urmia University of Medical Sciences, Iran. Health, 4, 94-100. doi: 10.4236/health.2012.42015.

Cited by

[1] Physics audit of selected diagnostic X-Ray machines in Ghana: towards implementation of a national dosimetry audit programme
Health and …, 2023
[2] Suboptimal chest radiography and artificial intelligence: the problem and the solution
Ghanem, CD Arru… - Diagnostics, 2023
[3] An Audit of X-Ray Request Form Completion at Two Namibian State Hospitals: How Compliant are the Doctors?
South African …, 2022
[4] Reject Analysis of Extraoral Dental Radiography Examination at The Dental Hospital in Semarang, Indonesia
MASHIJO: Medical Science and …, 2022
[5] Digital radiography reject analysis of examinations with multiple rejects: an Australian emergency imaging department clinical audit
2021
[6] Quality Assurance Audit of Digital Intraoral Periapical Radiographs at the Undergraduate Dental Clinics
2020
[7] Repeat Rate Analysis Of Lower Limb Radiograph For Digital Radiography In General Radiography At Pantai Klang Hospital Selangor
2020
[8] Quality Assurance Audit Of Intra-Oral Periapical Radiographs At The Undergraduate Dental School
2020
[9] Patient Dose Estimation from Digital Radiography Repeat Rate and Related Factors
2019
[10] Radiograph Reject Analysis in a Large Tertiary Care Hospital in Riyadh, Saudi Arabia
2019
[11] Radiographs reject analysis in a large tertiary care hospital in Riyadh
2019
[12] Artificial intelligence for point of care radiograph quality assessment
2019
[13] Reject analysis in digital radiography: A local study on radiographers and students' attitude in Iran
2019
[14] Effect of β-carotene patch application on gingival crevicular fluid volume after repeated periapical radiographic exposure
Majalah Kedokteran Gigi Indonesia, 2018
[15] Radiographic Reject Film Analysis in Radiology Department of a Teaching Hospital in Jos, Plateau State, Nigeria
African Journal of Medical Physics, 2018
[16] Entrance Skin Dose (ESD) in Patients Undergoing Forearm X-Rays at the Taraba State Specialist Hospital, Jalingo, Taraba State
2018
[17] Estimation of Entrance Skin Dose (ESD) in Patients Undergoing Forearm X-rays from Federal Medical Centre, Jalingo, Taraba State, Nigeria
AASCIT Journal of Physics, 2018
[18] The causes of reject images in a radiology department at a state hospital in Windhoek, Namibia
2018
[19] MINIMISASI WASTE PADA RADIOGRAPHY TEST PROYEK PERLUASAN KILANG MINYAK PT. PERTAMINA CILACAP MENGGUNAKAN METODE DMAIC
2018
[20] MINIMISASI WASTE PADA RADIOGRAPHY TEST PROYEK PERLUASAN KILANG MINYAK PT. PERTAMINA CILACAP MENGGUNAKAN METODE …
Jurnal Ilmiah Teknik Industri, 2018
[21] X-Ray Film Reject Analysis as a Quality Indicator in a Tertiary Health Centre in Northwestern Nigeria
2017
[22] Analyse Du Rebut Des Cliches Radiographiques Dans Le Service De Radiologie Et Imagerie Médicale Du Chu Campus De Lomé Au Togo
2017
[23] Radiation exposure: a study of hospital practices
2016
[24] Comparative of radiation dose and image quality of Conventional Multislice Computed Tomography (MSCT), Cone-Beam CT (CBCT) and periapical …
2016
[25] مقایسه دوز پرتویی و کیفیت تصویر توموگرافی کامپیوتری مولتی اسلایس (MSCT) معمولی، توموگرافی کامپیوتری پرتو مخروطی (CBCT) و رادیوگرافی پری اپیکال در تصویربرداری دندانپزشکی
مجله دندانپزشکی, 2016
[26] RADIATION EXPOSURE: A STUDY OF HOSPITAL PRACTICES.
Pakistan Armed Forces Medical Journal, 2016
[27] The Invention of Stretcher Trolley for Trauma Patient Radiography to Reduce Patient Transport Process
2016
[28] Developing a framework of quality in radiographic service delivery in Ghana
2016
[29] مقایسه دوز پرتویی و کیفیت تصویر توموگرافی کامپیوتری مولتی اسلایس (MSCT) معمولی، توموگرافی کامپیوتری پرتو مخروطی (CBCT) و رادیوگرافی پری اپیکال در …‎
2016
[30] Comparative of radiation dose and image quality of Conventional Multislice Computed Tomography (MSCT), Cone-Beam CT (CBCT) and periapical radiography in dental imaging
Journal of Dental Medicine-Tehran University of Medical Sciences, 2016
[31] Entrance Surface Air Kerma for Skull, Pelvis and Abdomen X-ray Examinations in Some Diagnostic Radiology Facilities in Akwa Ibom State, Nigeria
2016
[32] A Sheffield Hallam University thesis
2016
[33] Analysis of Image Quality for Hysterosalpingography Examinations
Scholars Journal of Applied Medical Sciences (SJAMS), 2015
[34] Evaluation of the Level of Protection in Radiology Departments of Kermanshah, Iran
Iranian Journal of Medical Physics, 2015
[35] Calidad de imagen de las radiografías de tórax, Emergencia hospital central Antonio M. Pineda, Barquisimeto, Venezuela.
2015
[36] Film Reject Analysis in Radiology Department of a Teaching Hospital In North-Eastern Nigeria
Nigerian Journal of Medical Imaging and Radiation Therapy, 2015
[37] بررسی فراوانی و علل تکرار تصاویر پرتونگاری در مراکز پرتونگاری دانشگاه علوم پزشکی زاهدان‎
دانشگاه علوم پزشکی بوشهر، طب جنوب, 2014
[38] FIELD MEDICINE
2014
[39] Assessment of radiographic film repeats rate and its causes in radiology centers of Zahedan University of medical sciences
2014
[40] Assessment of radiographic film repeats rate and its causes in radiology centers of Zahedan University of medical sciences.
Iranian South Medical …, 2014
[41] مقايسه دوز پرتويي و کيفيت تصوير توموگرافي کامپيوتري مولتي اسلايس (MSCT) معمولي، توموگرافي کامپيوتري پرتو مخروطي (CBCT) و راديوگرافي پري …‎
[42] تعیین الگوریتم جهت کاهش آرتیفکت فلزی در تصاویر CBCT‎
[43] " Radiology Department Abubakar Tafawa Balewa University Teaching Hospital Bauchi, Bauchi State, Nigeria.“Radiology Department State Specialist …
DZ Joseph, S Mohammed
[44] A STUDY TO ASSESS THE KNOWLEDGE OF RADIO IMAGING TECHNOLOGY AMONG STUDENTS TOWARDS HANDLING THE RADIOGRAPHIC …
[45] " Radiology Department Abubakar Tafawa Balewa University Teaching Hospital Bauchi, Bauchi State, Nigeria.“Radiology Department State Specialist Hospital …

Copyright © 2025 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.