Winston-Lutz-Gao Test on the True Beam STx Linear Accelerator

HTML  XML Download Download as PDF (Size: 693KB)  PP. 9-20  
DOI: 10.4236/ijmpcero.2019.81002    2,323 Downloads   7,795 Views  Citations
Author(s)

ABSTRACT

In the linear accelerator-based stereotactic radio surgery (SRS) and stereotactic body radiotherapy (SBRT) programs, single isocenter-multiple metastases treatment has become more and more popular due to their high efficiency in treatment time. However, the absence of a comprehensive quality assurance program is still the challenge for medical physicists. The Winston-Lutz-Gao test, which we developed two years ago, was performed for the first time on a True Beam STx (Varian Medical System) linear accelerator in this study. Beams were designed by Eclipse with gantry, collimator, and couch full rotations, and a 200-pound weight was placed on the couch to mimic real treatment. The “frameless SRS QA target pointer” from the Brainlab company, with a 3.5-mm metallic ball embedded in the center, was used as a phantom. Images were acquired by the portal imager built-in linear accelerator and analyzed directly by the Image browser in ARIA. We found that the farther the metastases were from the linac isocenter, the worse the congruence was between the beam mechanical and the radiation center. The farthest metastases should be within 6 cm from the linac isocenter per the AAPM TG-142 and American Society for Radiation Oncology (ASTRO) white paper criteria. To the best of our knowledge, this is the first off-isocenter Winston-Lutz test performed on a True Beam STx linear accelerator.

Share and Cite:

Gao, J. and Liu, X. (2019) Winston-Lutz-Gao Test on the True Beam STx Linear Accelerator. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 8, 9-20. doi: 10.4236/ijmpcero.2019.81002.

Cited by

[1] Elekta Unity MR-linac commissioning: mechanical and dosimetry tests
2023
[2] A simplified and effective off‐axis Winston–Lutz for single‐isocenter multi‐target SRS
Journal of Applied …, 2023
[3] Distance to Isocenter Directly Affects Margin and Inappropriate Margin Increases the Risk of Local Control Failure in LINAC-Based Single-Isocenter SRS or …
International Journal of Medical Physics, Clinical …, 2022
[4] Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary?
Journal of Applied …, 2022
[5] ExacTrac Dynamic workflow evaluation: Combined surface optical/thermal imaging and X‐ray positioning
Journal of Applied …, 2022
[6] Intracranial stereotactic radiotherapy in off-isocenter target with SyncTraX FX4
Physica Medica, 2022
[7] Single-isocenter stereotactic non-coplanar arc treatment of 200 patients with brain metastases: multileaf collimator size and setup uncertainties
Strahlentherapie und …, 2022
[8] Automatic measurement of beam‐positioning accuracy at off‐isocenter positions
Journal of Applied …, 2022
[9] Assessment of intra-fraction motion during automated linac-based SRS treatment delivery with an open face mask system
Physica medica, 2021
[10] Independent 6D quality assurance of stereotactic radiotherapy repositioning on linacs
2020
[11] Approximating a Classic Cone-Based Winston-Lutz Test Using a Continuously Rotating Collimator Concurrent with Beam Delivery and Its Applicability for Single …
2020
[12] Approximating a Classic Cone-Based Winston-Lutz Test Using a Continuously Rotating Collimator Concurrent with Beam Delivery and Its Applicability for …
2020
[13] Effects of Rotational Motion on Dose Coverage in Single Isocenter Multiple Target Stereotactic Radiosurgery
2019

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.