During the operation of an X-ray machine, if the radiation protection of X-ray room is insufficient, not only the patient but also clinical staffs as well as public are exposed to high X-ray exposures. In this research work, leakage and scattered radiations were measured from X-ray machine in the radiology department of Cape Coast Teaching hospital in the Cape Coast Municipality of Ghana. The scattered radiation exposures of X-rays in some selected areas within the facility were measured. The X-ray machine was operated for a range of kilo voltage peaks of kVp 77, 70, 63 and 66 with intensities 20, 6.3 and 8.0 mAs, which represents the main technique factors of some body parts such as chest, lumbar spine and extremities during radiographic examinations. The measurements were performed using a RADOS-120 Universal survey meter. The radiation doses rates measured in the various locations in the Radiology Department of Cape Coast Teaching Hospital of Ghana were in the range of 0.10 μSv/hr to 0.12 μSv/hr. These values were all within the background measurement of 0.10 μSv/hr. Moreover, there were no risks of high radiation doses to patients, staffs and people visiting the X-ray department. The results obtained indicated that within the radiology department of the Hospital, all the selected locations were very safe to patients, occupational workers and the general public which could be attributed to adequate shielding in the facility.

Share and Cite:

Owusu-Banahene, J. , Darko, E. , Charles, D. , Maruf, A. , Hanan, I. and Amoako, G. (2018) Scatter Radiation Dose Assessment in the Radiology Department of Cape Coast Teaching Hospital-Ghana. Open Journal of Radiology, 8, 299-306. doi: 10.4236/ojrad.2018.84033.

Cited by

[1] Evaluasi Perubahan Laju Paparan Radiasi Terhadap Faktor Eksposi pada Radiografi Umum Konvensional di Bidang Pelayanan Klinik Sehat Makassar
2022
[2] Shielding assessment in three diagnostic X-ray facilities in Asaba, South-South Nigeria: how compliant are we to radiation safety?
2021
[3] A dual-modality quantification of scattered radiation from head to female breasts during radiological investigations in a tertiary hospital in Nigeria
Egyptian Journal of …, 2021
[4] Assessment of Radiation Leakage from Diagnostic Rooms of Radiology Department of a Teaching Hospital in Kano, Northwestern Nigeria
2020
[5] Exposure Level to Caregivers Resulting From the Scattered Radiation During a Radiographic Procedure
2020
[6] Shielding assessment in two computed tomography facilities in South-South Nigeria: How safe are the personnel and general public from ionizing radiation?
2020
[7] Scattered Radiation Dose Calculation in the Multi-Bay Resuscitation Room using MCNP5 Code
Pertanika J. Sci. & Technol., 2019

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.