The Theoretically Studies and Field Testing of Self-Insulation Exterior Wall in the Hot Summer and Cold Winter Zone

HTML  XML Download Download as PDF (Size: 5301KB)  PP. 654-686  
DOI: 10.4236/epe.2017.910043    1,041 Downloads   2,024 Views  

ABSTRACT

The energy efficiency design of the exterior wall in the buildings of the hot summer and cold winter zone of China should consider the heat prevention in summer and the heat insulation in winter. The self-insulation of the exterior wall is a more feasible design to satisfy the energy efficiency of buildings in the zone. However, the systematic research is urgently needed for the self-insulation of the exterior wall in the hot summer and cold winter zone of China. The paper tested the thermal performance of the common non-clay materials such as shale sintered hollow brick, sand autoclaved aerated concrete block, etc. by means of indoor experiments. The energy efficiency effect of the common materials was verified using dynamic calculation soft PKPM and several constitutions of exterior wall with different main bricks and insulation materials on the heat bridge were simulated, too. Besides, the tests of the thermal performance of exterior wall in real constructions were carried out to testify the practical effect of the recommended constitutions of exterior wall with different main bricks and insulation materials on the heat bridge. The conclusions are: the physical and thermal properties of the six non-clay wall material are better than the clay porous brick; the thermal performance of the non-clay brick can be improved obviously through the rational arrangement of the holes; shale sintered hollow brick after increasing the holes and rationalizing the hole arrangement and sand autoclaved aerated concrete block are recommended for buildings in the hot summer and cold winter area of China. The dynamic calculation results show that the thermal performances of the non-clay materials are all satisfied with the energy efficiency; The heat transfer coefficient of the exterior wall with composition in which the main wall was sand autoclaved aerated concrete block and the material on the heat bridge was sand autoclaved aerated concrete plate, is the smallest among the three recommended compositions.

Share and Cite:

Yu, H. , Xu, Q. , Zhang, S. , Gao, W. and Xu, J. (2017) The Theoretically Studies and Field Testing of Self-Insulation Exterior Wall in the Hot Summer and Cold Winter Zone. Energy and Power Engineering, 9, 654-686. doi: 10.4236/epe.2017.910043.

Cited by

No relevant information.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.