ABSTRACT

Purpose: To investigate the impact of residual astigmatism on visual acuity (VA) after the implantation of a novel extended range of vision (ERV) intraocular lens (IOL) based on the correction of spherical and chromatic aberration. Method: The study enrolled 411 patients bilaterally implanted with the ERV IOL Tecnis Symfony. Visual acuity and subjective refraction were analyzed during the 4- to 6-month follow-up. The sample of eyes was stratified for four groups according to the magnitude of postoperative refractive astigmatism and postoperative spherical equivalent. Results: The astigmatism analysis included 386 eyes of 193 patients with both eyes of each patient within the same cylinder range. Uncorrected VAs for distance, intermediate and near were better in the group of eyes with lower level of postoperative astigmatism, but even in eyes with residual cylinders up to 0.75 D, the loss of VA lines was clinically not relevant. The orientation of astigmatism did not seem to have an impact on the tolerance to the residual cylinder. The SE evaluation included 810 eyes of 405 patients, with both eyes of each patient in the same SE range. Uncorrected VAs for distance, intermediate and near, were very similar in all SE groups. Conclusion: Residual cylinders up to 0.75 D after the implantation of the Tecnis Symfony IOL have a very mild impact on monocular and binocular VA. The Tecnis Symfony IOL shows a good tolerance to unexpected refractive surprises and thus a better “sweet spot”.

Share and Cite:

Cochener, B. (2017) Tecnis Symfony Intraocular Lens with a “Sweet Spot” for Tolerance to Postoperative Residual Refractive Errors. Open Journal of Ophthalmology, 7, 14-20. doi: 10.4236/ojoph.2017.71003.

Cited by

[1] Comparison of Bilateral Reading Performance Among Two Presbyopia-Correcting Intraocular Lenses
Journal of Refractive …, 2022
[2] Visual outcomes and safety of an extended depth-of-focus intraocular lens: results of a pivotal clinical trial
Journal of Cataract …, 2022
[3] Evaluation of Visual and Patient-Reported Outcomes After Implantation of Extended Depth of Focus Intraocular Lenses in Patients Not Suitable for Multifocal …
García, C Fuente-García, 2022
[4] The Tolerance of Refractive Errors of Extended Depth of Focus Intraocular Lens in Patients with Previous Corneal Refractive Surgery
2022
[5] Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical …
2019
[6] Multifocal Intraocular Lenses: The Johnson and Johnson Family of Lenses
2019
[7] Multifocal Intraocular Lenses
2019
[8] Refractive predictability and visual outcomes of an extended range of vision intraocular lens in eyes with previous myopic laser in situ keratomileusis
European journal of ophthalmology, 2018
[9] Comparative analysis of clinical outcomes of a monofocal and an extended-range-of-vision intraocular lens in eyes with previous myopic laser in situ keratomileusis
Journal of Cataract & Refractive Surgery, 2018