Health

Volume 8, Issue 10 (July 2016)

ISSN Print: 1949-4998   ISSN Online: 1949-5005

Google-based Impact Factor: 0.74  Citations  

A Derived Exposure Chart for Computed Radiography in a Negroid Population

HTML  XML Download Download as PDF (Size: 405KB)  PP. 953-958  
DOI: 10.4236/health.2016.810098    3,072 Downloads   5,368 Views  Citations

ABSTRACT

Background: Computed radiography has a wider exposure latitude when compared with film-screen imaging system. Consequently, the risk of dose creep is high. A conscientious effort is there-fore, needed by the radiographer to keep exposure as low as reasonably achievable. Objective: To derive a computed radiography exposure chart for a negroid population using AGFA photostimulable phosphor plates and a GE static X-ray machine. Materials and Method: A static X-ray machine, a digitizer, and photostimulable phosphor plates were used for the X-ray examination. Chest examinations were done at a Focus-Film-Distance (FFD) of 150 - 180 cm while all other examinations were conducted at 90 - 100 cm FFD. The range of exposure factors (kVp, mA and mAs) used by radiog-raphers in the centre was noted and the 90th percentile calculated. Over a three-month period, the patients were examined with the 90th percentile of tube potential (kVp) while keeping other factors constant. The kVp was gradually decreased and halted if radiologists and radiographers uncon-nected with the work expressed misgivings about the quality of the image. A similar procedure was adopted for the tube current (mA). The threshold adopted as low as reasonably achievable was the factor preceding the point of observation by other personnel. Metrics for central tendency from the statistical packages for social sciences, version 17.0 was used to analyze the data. Results: 335 subjects of both gender aged 0 - 92 years were examined by the researchers. Adult exposure factors used by the radiographers (and those derived by the researchers) had a range of 45 - 130 kVp (62 - 94 kVp), 63 - 320 mA (100 - 250 mA) and 4.0 - 25.0 mAs (5.0 - 20.0 mAs) respectively. Pediatric chest (and researchers-derived) factors were 50 - 75 kVp (52 - 65 kVp), 50 - 250 mA (100 - 220 mA) and 3.20 - 10.0 mAs (3.2 - 6.5 mAs) respectively. Conclusion: Upper threshold of adult (and paediatric) exposure factors in computed radiography with comparable equipment and accessories should not exceed 94 kVp (65 kVp), 250 mA (220 mA) and 20.0 mAs (6.5 mAs) respectively. The derived exposure chart is also adequate to address motion unsharpness in chest examinations.

Share and Cite:

Adejoh, T. , Ewuzie, O. , Ogbonna, J. , Nwefuru, S. and Onuegbu, N. (2016) A Derived Exposure Chart for Computed Radiography in a Negroid Population. Health, 8, 953-958. doi: 10.4236/health.2016.810098.

Cited by

[1] Exposure Determination in Gamma-Ray Radiography for Mammography Applications
Arabian Journal for …, 2022
[2] Evaluation of inadequately filled radiology request forms with its impact on patient radiation exposure and waiting time in a tertiary care hospital: A preliminary …
West African Journal …, 2021
[3] Determination of scatter radiation to the breast during lumbosacral x-ray examination using thermoluminescence dosimeter
2021
[4] Body Mass Index role in Lumbar Sacrum Spine Anterio-Posterior and Lateral Radiography by adjusting the radiation exposure factor mAs & kVp to avoid …
2021
[5] Optimization of patient radiation protection in digital diagnostic radiography examinations in Ghana
2020
[6] A SINGLE-CENTRE EXPERIENCE OF RADIATION DOSE MITIGATION IN COMPUTED RADIOGRAPHY USING DOSE CHARTS
2020
[7] Entrance skin dose assessment of selected computed radiography facilities in Ghana
2020
[8] Optimasi Kualitas Citra Radiografi Abdomen Berdasarkan Body Mass Index dan Tegangan Tabung pada Computed Radiography
2020
[9] Factors that affect Teaching and Learning among Undergraduate Radiography Students in two Nigerian Universities
Journal of Radiography & Radiation Sciences, 2019
[10] Retrospective evaluation of exposure indicators: a pilot study of exposure technique in digital radiography
Journal of Medical Radiation Sciences, 2019

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.