American Journal of Analytical Chemistry

Volume 2, Issue 4 (August 2011)

ISSN Print: 2156-8251   ISSN Online: 2156-8278

Google-based Impact Factor: 1.71  Citations  h5-index & Ranking

Enantioseparation of Palonosetron Hydrochloride and Its Related Enantiomeric Impurities by Computer Simulation and Validation

HTML  Download Download as PDF (Size: 347KB)  PP. 437-446  
DOI: 10.4236/ajac.2011.24053    7,656 Downloads   14,452 Views  Citations

Affiliation(s)

.

ABSTRACT

A rapid, simple and single stereo selective high-performance liquid chromatographic (HPLC) method was developed and validated for enantiomers of palonosetron hydrochloride (PALO) and its process related chiral impurities. A computer simulating software was used for the development of chiral method. The developed method was able to separate not only the enantiomers of palonosetron hydrochloride but also its process related chiral impurities within 12 min. The chromatographic separation was carried out by normal phase chromatography using a 3 µm column of cellulose based chiral stationary phase (Chiralcel-OD 250mm × 4.6mm) with a mobile phase comprised of n-hexane: ethanol: methanol: heptafluoro butyric acid: diethyl amine (70:15:15:0.05:0.1, v/v) at a flow rate of 1.0 mL/min. The effects of additive concentration as well as nature of polar organic modifier, flow rate, and temperature on enantioselectivity were investigated. The limit of detection (LOD) and limit of quantification (LOQ) of the palonosetron isomers and its related chiral impurities were found to be in the range 0.06-0.10 µg/mL and 0.14 - 0.24 µg/mL respectively. The method showed excellent linearity (R2 > 0.998) over a range of 0.14 to 1.125 µg/mL. The percentage recovery of the isomers in bulk drug samples ranged from 87.0 to 116.0.

Share and Cite:

M. Murthy, C. Krishnaiah, K. Jyothirmayi, K. Srinivas, K. Mukkanti, R. Kumar and G. samanta, "Enantioseparation of Palonosetron Hydrochloride and Its Related Enantiomeric Impurities by Computer Simulation and Validation," American Journal of Analytical Chemistry, Vol. 2 No. 4, 2011, pp. 437-446. doi: 10.4236/ajac.2011.24053.

Cited by

[1] Comparison of the Performance of Different Bile Salts in Enantioselective Separation of Palonosetron Stereoisomers by Micellar Electrokinetic Chromatography
Molecules, 2022
[2] SIMPLE AND RAPID RP-HPLC METHOD FOR SIMULTANEOUS DETERMINATION OF PALONOSETRON AND NETUPITANT IN SPIKED HUMAN PLASMA
Journal of Advanced …, 2021
[3] Chiral and achiral liquid chromatographic separation of palonosetron hydrochloride and its related impurities utilizing two different stationary phases: Polysaccharide …
2021
[4] Development and Validation of New Analytical Method for The Simultaneous Estimation of Netupitant And Palonosetron In Pharmaceutical Dosage Form
2021
[5] SIMPLE AND RAPID RP-HPLC METHOD FOR SIMULTANEOUS DETERMINATION OF PALONOSETRON AND NETUPITANT IN SPIKED HUMAN PLASMA.
2021
[6] Recent Trends in Chiral Separation-A Collective Paradigm of Selected Chiral Impurities
2020
[7] DEVELOPMENT AND VALIDATION OF STABILITY INDICATING HPLC METHOD FOR SIMULTANEOUS DETERMINATION OF FOSNETUPITANT AND …
2020
[8] Studies of stress degradation and impurity profiles of some 5-ht3 antagonists
2019
[9] Method development and validation for simultaneous quantification of netupitant and palonosetron in bulk and pharmaceutical dosage form and their forced …
2019
[10] Method development and validation for simultaneous quantification of netupitant and palonosetron in bulk and pharmaceutical dosage form and their …
Asian journal of pharmaceutical and clinical research, 2019
[11] METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS QUANTIFICATION OF NETUPITANT AND PALONOSETRON IN BULK AND …
2019
[12] Studies of Stress Degradation of Ramosetron Hydrochloride, a 5-HT3 Antagonist
2018
[13] Studies of Degradation Kinetics of a 5-HT3 Antagonist, Ramosetron Hydrochloride: Effects of Temperature
2018
[14] A VALIDATED STABILITY INDICATING RP-HPLC METHOD FOR SIMULTANEOUS DETERMINATION OF NETUPITANT AND PALENOSERTON IN PHARMACEUTICAL FORMULATIONS
2016
[15] A validated stability indicating RP-HPLC method for simultaneous determination of netupitant and palonosetron in pharmaceutical formulations
2016
[16] Solvent‐modified MEKC for the enantioseparation of palonosetron hydrochloride and related enantiomeric impurities
Electrophoresis, 2015
[17] A novel validated RP-HPLC-DAD method for the simultaneous estimation of Netupitant and Palonosetron in bulk and pharmaceutical dosage form with forced degradation studies
2015
[18] A novel validated RP-HPLC-DAD method for the simultaneous estimation of Netupitant and Palonosetron in bulk and pharmaceutical dosage form with forced …
2015
[19] A novel validated RP-HPLC-DAD method for the simultaneous estimation of Netupitant and Palonosetron in bulk and pharmaceutical dosage form with …
2015
[20] Development of Stereoselective Method for the Quantification of Stereoisomers and Geometrical Isomer of Pitavastatin Calcium by Enhanced Approach
Chromatographia, Springer, 2014
[21] Separation of palonosetron stereoisomers by electrokinetic chromatography using sodium cholate as chiral selector: Comparison of separation modes and elucidation of migration orders
Electrophoresis, Wiley Online Library, 2013
[22] Separation of palonosetron stereoisomers by electrokinetic chromatography using sodium cholate as chiral selector: Comparison of separation modes and elucidation …
Electrophoresis, 2013

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.