Open Journal of Radiology

Volume 5, Issue 3 (September 2015)

ISSN Print: 2164-3024   ISSN Online: 2164-3032

Google-based Impact Factor: 0.33  Citations  

Evaluation of Entrance Skin Radiation Exposure Dose for Pediatrics Examined by Digital Radiography at Asser Central Hospital-KSA

HTML  XML Download Download as PDF (Size: 263KB)  PP. 125-130  
DOI: 10.4236/ojrad.2015.53019    4,397 Downloads   5,776 Views  Citations

ABSTRACT

Assessment of entrance skin doses for patients in Digital radiography examinations should be made as a means for the optimization of the radiation protection of the patients. We measured the entrance skin dose (ESD) received by 50 pediatrics undergoing 12 types of diagnostic X-ray examination at Radiology Department of Asser Central Hospital-KSA. The entrance skin dose ESD was determined via measurements parameters: focus to skin distance (FSD), tube current (mAs) and tube voltage (kV) in arithmetical equation. The mean ± SD for ESDs were found to be 0.16 ± 0.03, 0.21 ± 0.01, 0.63 ± 0.26, 0.55 ± 0.09, 0.15 ± 0.05, 0.27 ± 0.06, 0.41 ± 0.19, 0.46 ± 0.18, 0.46 ± 0.12, 0.20 ± 0.02, 0.39 ± 0.01, 0.29 ± 0.03, for PA chest, foot, AP pelvis, PA skull, PA hand, AP arm, ankle, AP shoulder, abdomen, forearm, AP femur, AP elbow consequently. Our study is considered as an attempt to evaluate the ESDs received by digital radiographic x-ray machine for children aged between 2 - 15 years old, taking in our considerations number of other variables. The mean ESD values obtained are found to be within the standard reference. The data obtained may add to the available information in national records for general use. It may provide guidance on where efforts on dose reduction will need to be directed to fulfill the requirements of the optimization process and serve as a reference for future researches.

Share and Cite:

Eljak, S. , Ayad, C. and Abdalla, E. (2015) Evaluation of Entrance Skin Radiation Exposure Dose for Pediatrics Examined by Digital Radiography at Asser Central Hospital-KSA. Open Journal of Radiology, 5, 125-130. doi: 10.4236/ojrad.2015.53019.

Cited by

[1] Evaluation of entrance surface dose and justification of pediatrics chest radiography in three university-affiliated hospitals at Yaounde-Cameroon
2022
[2] Status of Radiation Dose Levels in Paediatric Chest Radiography in a Tertiary Hospital in Ghana
Sampong, L Arthur, E Boahen… - Radiation Protection …, 2021
[3] Assessment and comparative study of Entrance Skin Dose for digital panoramic x-Ray equipments
2019
[4] Sağlık Çalışanlarının Radyasyon Tutumunu Belirleme Ölçeği Geliştirme Ve Uygulama Çalışması
2019
[5] Entrance Skin Dose (ESD) in Patients Undergoing Forearm X-Rays at the Taraba State Specialist Hospital, Jalingo, Taraba State
2018
[6] Estimation of Entrance Skin Dose (ESD) in Patients Undergoing Forearm X-rays from Federal Medical Centre, Jalingo, Taraba State, Nigeria
AASCIT Journal of Physics, 2018
[7] Evaluation of the Entrance Surface Dose (ESD) and Radiation Dose to the Radiosensitive Organs in Pediatric Pelvic Radiography
2017
[8] The abdominal radiation doses for paediatric patients undergoing X-ray examinations at southern Saudi Arabia
Australasian Physical & Engineering Sciences in Medicine, 2017
[9] Optimization of Radiation Dose and Image Quality in Pediatric Chest and Abdomen Radiography
2017
[10] Assessment of entrance skin doses and radiation protection for pediatric X-ray examination
2017
[11] THE UNREGULATED USE OF X-RAY DOSE AND THE ASSOCIATED CANCER RISK TO PATIENTS UNDERGOING SOME DIAGNOSTIC X-RAY …

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.