A noninvasive method for monitoring blood pressure, based on the principles established by Riva-Rocci and Korotkoff (K), is described; it furnishes, after a single compression-deflation cycle of the arm-encircling cuff, values of sys-tolic and diastolic blood pressures as well as the contours of the brachial arterial pulse and the corresponding volume pulse. K-sounds are detected by a single microphone situated in the cubital fossa, and the time-varying cuff pressure P(t) is read by a piezoresistive pressure sensor. The behavior of P(t) during deflation is resolved into two parts, P(t)=p(t)+b(t); p is a train of posi-tive going pulses (arising from arterial pulsa-tions), whereas b is a slowly changing baseline. Noise pulses in the microphone output are re-jected by using the observation that the first few K-sounds are emitted when p is close to a maxi-mum, and the last few when dp/dt is close to a maximum. The performance of the instrument is illustrated by showing how it copes with ambi-ent noise and involuntary manual perturbations of P, and by presenting contours of various pulses.

Share and Cite:

Naqvi, K. , Parigi, L. , Vellani, C. and Kumar, S. (2008) Noninvasive method for determining blood pressure and contours of arterial and volume pulses. Journal of Biomedical Science and Engineering, 1, 79-84. doi: 10.4236/jbise.2008.12013.

Cited by

[1] Acoustomyographic Signals Recorded on the Human Head—A New Channel for Obtaining Physiological Information
2019
[2] Акустомиографические сигналы, снимаемые с головы человека,–новый канал получения физиологической информации
2019
[3] Elimination of artifacts in oscillometric waveforms using empirical wavelet transform to improve accuracy of blood pressure estimation
2015
[4] Motion Analysis of Elderly People Based on Fall Detection Algorithm
BIOSCIENCES BIOTECHNOLOGY RESEARCH ASIA, 2015
[5] Обнаружение новых акустических сигналов от головы человека
2014
[6] Detection of new acoustic signals from the human head
Acoustical Physics, 2014
[7] OBNARUZhENIE NOVYKh AKUSTIChESKIKh SIGNALOV OT GOLOVY ChELOVEKA
VI Mirgorodskii, VV Gerasimov, SV Peshin - Akusticheskii zhurnal, 2014, 2014
[8] Novel fall detection algorithm for the elderly people
2014
[9] Noninvasive determination of arterial elasticity and blood pressure. Part I: arterial volume pulsations and elastogram
Blood pressure monitoring, 2013
[10] Consideraciones de Dise?o para la Integración de Dos Métodos no Invasivos de Medición de la Presión Arterial en un Dispositivo Portable
V Latin American Congress on Biomedical Engineering CLAIB 2011 May 16-21, 2011, Habana, Cuba. Springer Berlin Heidelberg, 2013., 2013
[11] Consideraciones de diseño para la integración de dos metodos no invasivos de medición de la presión arterial en un dispositivo portable
2013
[12] An innovative oscillometric blood pressure measurement: Getting rid of the traditional envelope
Medical Measurements and Applications Proceedings (MeMeA), 2012 IEEE International Symposium on. IEEE, 2012., 2012
[13] Oscillometric method for noninvasive determination of the arterial elasticity
CR Acad Bulg Sci, 2012
[14] A method for retrieving the waveform of the pressure pulsations from the output of an electronic oscillometer
Journal of Biomedical Science and Engineering, 2008
[15] A method for retrieving the waveform of the pres-sure pulsations from the output of an electronic os-cillometer
2008

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.