Open Journal of Polymer Chemistry

Volume 4, Issue 3 (August 2014)

ISSN Print: 2165-6681   ISSN Online: 2165-6711

Google-based Impact Factor: 4.63  Citations  

Toluidine Blue O-Gelatin Gel Dosimeter for Radiation Processing

HTML  Download Download as PDF (Size: 2747KB)  PP. 56-61  
DOI: 10.4236/ojpchem.2014.43007    3,855 Downloads   5,006 Views  Citations

ABSTRACT

In this study the spectrophotometric response of the Toluidine Blue O (TBO)-gelatin gel dosimeter irradiated with gamma rays was characterized. Preparation of dyed-gelatin gel takes place in neutral medium; to give eventually gel dosimeter has a sharp absorbance peak at 635 nm that bleaches quantitatively upon irradiation and the colour change can be measured with UV-VIS spectrophotometer. The useful dose range was 1 - 150 Gy. The radiation chemical yield (G-value) of gel dosimeter was calculated and found to increase by increasing concentration of dye. Post-irradiation storage on the response of gel is discussed. The dose response function, radiation sensitivity, and dependences of the response on environmental factors were studied.

Share and Cite:

Gafar, S. , El-Kelany, M. , El-Ahdal, M. and El-Shawadfy, S. (2014) Toluidine Blue O-Gelatin Gel Dosimeter for Radiation Processing. Open Journal of Polymer Chemistry, 4, 56-61. doi: 10.4236/ojpchem.2014.43007.

Cited by

[1] Discolouring 3D Gel Dosimeter for UV Dose Distribution Measurements
Andrzejczak, M Kozicki - Materials, 2022
[2] Effect of gamma rays on sensitive prepared dyed gels as radiation dosimeters
Shawadfy, MA El-Kelany - Journal of Radioanalytical and …, 2022
[3] Preparation of polymer gel dosimeters for low gamma irradiation dose
Kelany, EE Khozemy, H Goda, B Awad - Radiochimica Acta, 2022
[4] Feasibility of utilizing radiochromic nickel complex gel for radiation processing
Journal of …, 2022
[5] Determining Optical Band Gap Energy of Chitosan Biopolymer Film as the Effect of Gamma Rays Irradiation
2021
[6] Possible use of tetrabromophenolphthalein ethyl ester as a liquid dosimeter
2020
[7] Exploiting the cellular redox control system for activatable Photodynamic Therapy
2019
[8] Radiation-induced free radicals from different milk powders and its possible use as radiation dosimeters
2019
[9] Exploiting the Cellular Redox‐Control System for Activatable Photodynamic Therapy
2019
[10] Spectrophotometric properties of Eosin gel and its possible use as radiation dosimeter
Egyptian Journal of Pure and Applied Science, 2019
[11] Radiation Induced Free-Radicals for EPR Dosimetry Applications
Silicon, 2018
[12] Spectrophotometric properties of azo dye metal complex and its possible use as radiation dosimeter
Journal of Radiation Research and Applied Sciences, 2018
[13] Radiation Dosimetry—A Different Perspective of Polymer Gel
Polymer Gels, 2018
[14] Current scenario of biomedical aspect of metal-based nanoparticles on gel dosimetry
Applied Microbiology and Biotechnology, 2016
[15] Preparation of radiation monitoring labels to γ ray
Optik, 2016
[16] Study the Effect of X-Ray Radiation on Some Polymeric Films Polyvinyl alcohol polymeric films and Its Possible Use in Radiation Dosimetry
2016

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.