Feasible Method to Assess the Performance of a Lung Cancer CT Screening CAD System in Clinical Practice: Dependence on Nodule Size and Density

HTML  XML Download Download as PDF (Size: 945KB)  PP. 107-116  
DOI: 10.4236/ijmpcero.2014.32016    3,574 Downloads   5,454 Views  Citations

ABSTRACT

Detection of small pulmonary nodules is the goal of lung cancer screening. Computer-aided detection (CAD) systems are recommended to use in lung cancer computed tomography (CT) screening to increase the accuracy of nodule detection. Size and density of lung nodules are primary factors in determining the risk of malignancy. Therefore, purpose of this study is to apply computer-simulated virtual nodules based on the point spread function (PSF) measured in same scanner (maintaining spatial resolution condition) to assess the CAD system performance dependence on nodule size and density. Virtual nodules with density differences between lung background and nodule density (ΔCT) values (200, 300 and 400 HU) and different sizes (4 to 8 mm) were generated and fused on clinical images. CAD detection was performed and free-response receiver operating characteristic (FROC) curves were obtained. Results show that both density and size of virtual nodules can affect detection efficiency. Detailed results are possible to use for quantitative analysis of a CAD system performance. This study suggests that PSF-based virtual nodules could be effectively used to assess the lung cancer CT screening CAD system performance dependence on nodule size and density.

Share and Cite:

Marasinghe, J. , Ohkubo, M. , Kobayashi, H. , Murao, K. , Matsumoto, T. , Sone, S. and Wada, S. (2014) Feasible Method to Assess the Performance of a Lung Cancer CT Screening CAD System in Clinical Practice: Dependence on Nodule Size and Density. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 3, 107-116. doi: 10.4236/ijmpcero.2014.32016.

Cited by

[1] CT 画像 3D-PSF の胸部 CT-CAD の QA への応用 (4) 3D-PSF の応用 2. virtual nodule の胸部 CT-CAD の QA への応用
2019
[2] 两种 CT 胸部扫描模式下 DLP 值的测量与分析
2019
[3] 低剂量 CT 在肺癌筛查中的应用研究
2018
[4] 胸部 CT 画像における空間分解能に基づいた realistic virtual nodule の生成に関する基礎的研究
2018
[5] Generation of realistic virtual nodules based on three‐dimensional spatial resolution in lung computed tomography: A pilot phantom study
Medical physics, 2017
[6] A method for evaluating the performance of computer-aided detection of pulmonary nodules in lung cancer CT screening: detection limit for nodule size and density
2016
[7] Quality assurance of lung cancer CT screening CAD system by applying PSF-based reference virtual nodule set.
2015
[8] Quality Assurance of Lung Cancer CT Screening CAD Systems: Feasibility Study with
Thesis, 2015
[9] Quality Assurance of Lung Cancer CT Screening CAD Systems: Feasibility Study with PSF-based Virtual Nodules
2015
[10] 肺がん CT 検診 CAD システムの現状と今後の展望
医学物理, 2015
[11] CT 検診による肺がん死亡率低減—医学物理からの寄与—
医学物理, 2015

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.