Development of forearm impedance plethysmography for the minimally invasive monitoring of cardiac pumping function

HTML  Download Download as PDF (Size: 236KB)  PP. 122-129  
DOI: 10.4236/jbise.2011.42018    6,488 Downloads   12,171 Views  Citations

Affiliation(s)

.

ABSTRACT

It is essential to continuously and non-invasively monitor the cardiac pumping function in clinical setting. Thus, the study aimed to explore a regional impedance phethysmographic method to assess the changes in stroke volume. To do this, we developed a plethysmographic device that was capable of delivering a single-frequency current with constant amplitude and of recording electrical impedance signals of biological tissue. The electrical impedance plethy- smographic waveform form the lower arm was measured with the impedance plethysmographic device, and simultaneously the end-systolic and end- diastolic volumes of the left ventricle were obtained with a two-dimension echocardiographic system in fourteen healthy subjects before and immediately after a thirty-second breath-hold maneuver. For the 14 subjects, a linear correlation coefficient of 0.79 (p < 0.001) was obtained between the changes in peak amplitude of the forearm impedance waveform and the changes in stroke volume before and just after the breath-hold test. In addition, the changes in the mean area under the impedance curve and the change in stroke volume were also correlated linearly (r = 0.71, p < 0.005). In summary, the forearm impedance plethysmography may be employed to evaluate the beat-to-beat alteration in cardiac stroke volume, suggesting its potential for long-term monitoring cardiac pumping performance.

Share and Cite:

Wang, J. , Hu, W. , Kao, T. , Liu, C. and Lin, S. (2011) Development of forearm impedance plethysmography for the minimally invasive monitoring of cardiac pumping function. Journal of Biomedical Science and Engineering, 4, 122-129. doi: 10.4236/jbise.2011.42018.

Cited by

[1] Intelligent Bio-Impedance System for Personalized Continuous Blood Pressure Measurement
Biosensors, 2022
[2] Bioelectrical Impedance Spectroscopy for Monitoring Mammalian Cells and Tissues under Different Frequency Domains: A Review
Leyva… - ACS Measurement …, 2022
[3] STUDY OF BIOMEDICAL SIGNAL MEASUREMENT & ANALYSIS TECHNIQUES
2022
[4] Cardiac contractility assessment from arm impedance plethysmography (IPG)
Qayum, A Hilton… - … World Congress on …, 2022
[5] Mehrkanal-Bioimpedanz-Instrumentierung
2021
[6] Bioimpedance analysis as a tool for hemodynamic monitoring: overview, methods and challenges
2021
[7] Bio-impedance measurement optimization for high-resolution carotid pulse sensing
2021
[8] Impact of Electrodes Separation Distance on Bio-impedance Diagnosis.
2021
[9] Predictive analysis of identification and disease condition monitoring using bioimpedance data
2020
[10] Single-channel Bio-impedance Measurement for Wearable Continuous Blood Pressure Monitoring
2020
[11] Simulation of Signal Generation and Measuring Circuit and Real Time IoT Based Electrical Bio Impedance Cardiac Monitoring System
2019
[12] Modelling Dynamically Re-sizeable Electrodes (DRE) for Targeted Transcutaneous Measurements in Impedance Plethysmography
2019
[13] Development of bioimpedance sensing device for wearable monitoring of the aortic blood pressure curve
tm - Technisches Messen, 2018
[14] Heart Rate Extraction from Electrical Bio-impedance Signal
2016
[15] Вдосконалення методів та засобів імпедансометрії для дослідження тканин організму людини
2016
[16] Portable devices and methods for measuring nutritional intake
2015
[17] Electromagnetic activation of the calf muscle pump
ProQuest Dissertations Publishing, 2014
[18] Measurement of Cardiac Output using Bioimpedance Method
2013
[19] Parallel Multiclass Support Vector Interpretation of Haemodynamic Parameters for Manifestation of Aortic and Arterial Occlusive Diseases
Soft Computing Applications. Springer Berlin Heidelberg, 2013
[20] Физико-математические основы измерений биологического импеданса при исследовании электродермальной активности
Одеський медичний журнал, 2013
[21] PHYSICO-MATHEMATICAL BASIS OF THE BIOLOGICAL IMPEDANCE STUDY—CASE OF THE ELECTRODERMAL ACTIVITY
ОДЕСЬКИЙ МЕДИЧНИЙ ЖУРНАЛ, 2013
[22] Sheeba Santhosh, A. Vimala Juliet &

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.