Energy and Power Engineering

Volume 5, Issue 4 (July 2013)

ISSN Print: 1949-243X   ISSN Online: 1947-3818

Google-based Impact Factor: 0.66  Citations  

Calculation of the Choked Back Pressure for Steam Turbines with Air Cooled Condensers

HTML  Download Download as PDF (Size: 84KB)  PP. 1474-1477  
DOI: 10.4236/epe.2013.54B279    7,882 Downloads   10,381 Views  Citations

ABSTRACT

The choked back pressure characteristic of the steam turbine unit with air cooled condenser is very different with the unit with wet cooling technology, and the understanding of the choked back pressure performance change with operation load is important to guide the economic operation of the unit. One simplified Variable Operation Condition Analysis Method was put forward for calculation of the unit output-turbine back pressure characteristics. Based on this method, the choked back pressure for each operation load can be determined. An example was given for a super-critical, regenerative single-shaft, 2-casing with 2-exhaust steam turbine generation unit with air cooled condenser. The calculation result was provided and compared with the result of the unit with wet cooling technology.

Share and Cite:

H. Yang, S. Chang and R. Wu, "Calculation of the Choked Back Pressure for Steam Turbines with Air Cooled Condensers," Energy and Power Engineering, Vol. 5 No. 4B, 2013, pp. 1474-1477. doi: 10.4236/epe.2013.54B279.