Open Journal of Orthopedics

Volume 3, Issue 6 (October 2013)

ISSN Print: 2164-3008   ISSN Online: 2164-3016

Google-based Impact Factor: 0.25  Citations  h5-index & Ranking

Reattachment of the Osteotomized Greater Trochanter in Hip Surgery Using an Ultrahigh Molecular Weight Polyethylene Fiber Cable: A Multi-Institutional Study

HTML  Download Download as PDF (Size: 907KB)  PP. 283-289  
DOI: 10.4236/ojo.2013.36052    3,748 Downloads   6,080 Views  Citations

ABSTRACT

The purpose of this multicenter study was to evaluate the clinical performance of an ultrahigh molecular weight polyethylene (UHMWPE) fiber cable for re-attachment of the osteotomized greater trochanter in hip surgery. Included in the study were 85 hips that had undergone surgery with greater trochanter osteotomy, including 50 hip arthroplasty procedures and 35 hip osteotomies. The osteotomized greater trochanter was reattached using one or more UHMWPE fiber cables. The bone union and displacement of the greater trochanter were assessed in radiographs for up to 12 months after surgery. Non-union of the osteotomy site occurred in 4.7% of the cases. In approximately 90% of the cases, displacement was less than 2 mm at up to 12 months after surgery. The UHMWPE fiber cable was a good biomaterial for reattaching the osteotomized greater trochanter and may also be an option for osteosynthesis procedures.

Share and Cite:

S. Jingushi, T. Kawano, H. Iida, K. Oe, K. Ohzono, Y. Nakamura, M. Osaki, H. Ohara, S. Lee, T. Hara and N. Tomita, "Reattachment of the Osteotomized Greater Trochanter in Hip Surgery Using an Ultrahigh Molecular Weight Polyethylene Fiber Cable: A Multi-Institutional Study," Open Journal of Orthopedics, Vol. 3 No. 6, 2013, pp. 283-289. doi: 10.4236/ojo.2013.36052.

Cited by

[1] Trochanteric claw plate fixation for greater trochanteric fracture or osteotomy in total hip arthroplasty
2022
[2] The contact pressure of ultra-high-molecular-weight polyethylene cables is twice as high as that of titanium cables
2021
[3] Trochanteric osteotomy in revision total hip arthroplasty
2020
[4] Reattachment of an osteotomized greater trochanter in total hip arthroplasty using an ultra-high molecular weight polyethylene fiber cable
Journal of Orthopaedic Science, 2018
[5] Ultra-High Molecular Weight Polyethylene Tape Applied for Distal Humeral Condyle Fracture around Total Elbow Arthroplasty in Patients with Rheumatoid Arthritis: Report of Two Cases
Open Journal of Orthopedics, 2015
[6] Ultra-High Molecular Weight Polyethylene Tape Applied for Distal Humeral Condyle Fracture around Total Elbow Arthroplasty in Patients with Rheumatoid …
2015
[7] Ultra-high molecular weight polyethylene tape applied for distal humeral condyle fracture around total elbow arthroplasty in patients with rheumatoid arthritis …
Open Journal of Orthopedics, 2015
[8] ネスプロンケーブルを使用したステム周囲骨折の治療経験
中部日本整形外科災害外科学会雑誌, 2014
[9] 超高分子量ポリエチレン製ケーブルを骨接合術に使用し抜去した症例の検討
中部整災誌, 2014

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.