The Reproducibility of Patient Setup for Head and Neck Cancers Treated with Image-Guided and Intensity-Modulated Radiation Therapies Using Thermoplastic Immobilization Device

HTML  Download Download as PDF (Size: 750KB)  PP. 117-124  
DOI: 10.4236/ijmpcero.2013.24016    4,676 Downloads   9,352 Views  Citations

ABSTRACT

The reproducibility of patient setup is an important issue for head and neck cancers treated with intensity-modulated radiation therapy (IMRT). In this study, an image-guided radiation therapy (IGRT) system has been used to minimize the uncertainty of patient setup while standard thermoplastic masks were used to provide adequate immobilization for the head and neck. However, they do not provide sufficient immobilization of the shoulders, which is an important requirement in comprehensive nodal irradiation. Therefore, we investigated the setup and rotational shifts in head and neck cancer patients undergoing IMRT for which this immobilization device had been used together with an IGRT system. The setup and rotational shifts of patients were analyzed using the ExacTrac X-ray 6D IGRT system. The patients were classified as having head and neck tumors in the upper or lower regions. The upper neck nodes included lymph nodal level II while the lower neck nodes included lymph nodal levels III and IV. Clinical data from 227 treatment sessions of 12 head and neck cancer patients were analyzed. The random translational error in inter-and intra-fraction errors of the anterio-posterior (AP) direction might influence the rotational errors of pitch and roll in the upper region. At the same time, the random translational error in the inter-and intra-fraction errors of the AP direction might influence the rotational error of roll in the lower region. We believe that these random translational errors should be considered during treatment. We found variability in random translational errors for different regions in the anatomy of head and neck cancer patients due to rotational shifts. Depending on the location of the primary lesion or the selected nodal treatment targets, these relative positional variations should be considered when setup and rotational shifts are corrected with IGRT systems before treatment.

Share and Cite:

A. Nakata, K. Tateoka, K. Fujimoto, Y. Saito, T. Nakazawa, T. Abe, M. Yano and K. Sakata, "The Reproducibility of Patient Setup for Head and Neck Cancers Treated with Image-Guided and Intensity-Modulated Radiation Therapies Using Thermoplastic Immobilization Device," International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, Vol. 2 No. 4, 2013, pp. 117-124. doi: 10.4236/ijmpcero.2013.24016.

Cited by

[1] The noise navigator for MRI-guided radiotherapy: an independent method to detect physiological motion
2020
[2] A spatial neighborhood methodology for computing and analyzing lymph node carcinoma similarity in precision medicine
2020
[3] The effect of designing a rotational planning target volume on sparing pharyngeal constrictor muscles in patients with oropharyngeal cancer
2020
[4] Precision Risk Analysis of Cancer Therapy with Interactive Nomograms and Survival Plots
2018
[5] Intrafraction motion quantification and planning target volume margin determination of head-and-neck tumors using cine magnetic resonance imaging
Radiotherapy and Oncology, 2018
[6] Assessment of positional reproducibility in the head and neck on a 1.5-T MR simulator for an offline MR-guided radiotherapy solution
2018
[7] Improved setup and positioning accuracy using a three-point customized cushion/mask/bite-block immobilization system for stereotactic reirradiation of head and neck …
2016
[8] Improved setup and positioning accuracy using a three‐point customized cushion/mask/bite‐block immobilization system for stereotactic reirradiation of head …
Journal of Applied Clinical Medical Physics, 2016
[9] Improved setup and positioning accuracy using a three‐point customized cushion/mask/bite‐block immobilization system for stereotactic reirradiation of head and …
Journal of Applied Clinical Medical Physics, 2016

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.