ABSTRACT

Diffusion tensor imaging (DTI) is mainly applied to white matter fiber tracking in human brain, but there is still a debate on how many diffusion gradient directions should be used to get the best results. In this paper, the performance of 7 protocols corresponding to 6, 9, 12, 15, 20, 25, and 30 noncollinear number of diffusion gradi-ent directions (NDGD) were discussed by com-paring signal-noise ratio (SNR) of tensor- de-rived measurement maps and fractional ani-sotropy (FA) values. All DTI data (eight healthy volunteers) were downloaded from the website of Johns Hopkins Medical Institute Laboratory of Brain Anatomi-cal MRI with permission. FA, apparent diffusion constant mean (ADC-mean), the largest eigen-value (LEV), and eigenvector orientation (EVO) maps associated with LEV of all subjects were calculated derived from tensor in the 7 proto-cols via DTI Studio. A method to estimate the variance was presented to calculate SNR of these tensor-derived maps. Mean ± standard deviation of the SNR and FA values within re-gion of interest (ROI) selected in the white mat-ter were compared among the 7 protocols. The SNR were improved significantly with NDGD increasing from 6 to 20 (P<0.05). From 20 to 30, SNR were improved significantly for LEV and EVO maps (P<0.05), but no significant dif-ferences for FA and ADC-mean maps (P>0.05). There were no significant variances in FA val-ues within ROI between any two protocols (P> 0.05). The SNR could be improved with NDGD in-creasing, but an optimum protocol is needed because of clinical limitations.

Share and Cite:

Zhang, N. , Deng, Z. , Wang, F. and Wang, X. (2009) The effect of different number of diffusion gradients on SNR of diffusion tensor-derived measurement maps. Journal of Biomedical Science and Engineering, 2, 96-101. doi: 10.4236/jbise.2009.22018.

Cited by

[1] Methods for the analysis and characterization of brain morphology from MRI images
2022
[2] СРАВНЕНИЕ ДИАГНОСТИЧЕСКОЙ ВОЗМОЖНОСТИ ДИФФУЗИОННО-ТЕНЗОРНОЙ МРТ С МАГНИТНО-РЕЗОНАНСНОЙ ТРАКТОГРАФИЕЙ РАКА …
… ЖУРНАЛ МЕДИЦИНЫ И ПСИХОЛОГИИ 2022, Том 5 …, 2022
[3] Mesoscale diffusion magnetic resonance imaging of the ex vivo human hippocampus
2020
[4] Characterization of prostate cancer using diffusion tensor imaging: A new perspective
2019
[5] Decoding the Neural Basis of Age-related Decline: Combining Pattern Recognition and Diffusion Magnetic Resonance Imaging
2019
[6] Diffusion sensitivity enhancement filter for raw DWIs
2018
[7] Comparison Of Number Of Diffusion Gradient Direction In Brain Imaging Diffusion Tensor; Case Study Of Tumor Brain
2017
[8] Diffusion Tensor Imaging Based Tractography of Human Brain Fiber Bundles
2015
[9] Alternative formats
ETRI Journal, 2015
[10] Effect of Increasing Diffusion Gradient Direction Number on Diffusion Tensor Imaging Fiber Tracking in the Human Brain
Korean Journal of Radiology, 2015
[11] X-ray luminescence computed tomography imaging based on X-ray distribution model and adaptively split Bregman method
Biomedical Optics Express, 2015
[12] Optimal Power Allocation for Channel Estimation of OFDM Uplinks in Time-Varying Channels
ETRI Journal, 2015
[13] Global versus tract-specific components of cerebral white matter integrity: relation to adult age and perceptual-motor speed
Brain Structure and Function, 2014
[14] Diffusion tensor based global tractography of human brain fiber bundles
Electrical and Computer Engineering (ICECE), 2014 International Conference on, 2014
[15] 弥散梯度方向数目对DTI 测量值的影响
中国医学影像技术, 2010
[16] Effect of Different Number of Diffusion Gradients on Dispersion Degree of FA Values and Its SNR
Bioinformatics and Biomedical Engineering (iCBBE), 2010 4th International Conference on. IEEE, 2010
[17] 弥散梯度方向数目对 DTI 测量值的影响
中國醫學影像技術, 2010

Copyright © 2025 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.