Open Journal of Radiology

Volume 3, Issue 3 (September 2013)

ISSN Print: 2164-3024   ISSN Online: 2164-3032

Google-based Impact Factor: 0.33  Citations  

Three-Dimensional Rotational Angiography in Congenital Heart Disease: Estimation of Radiation Exposure

HTML  Download Download as PDF (Size: 884KB)  PP. 124-129  
DOI: 10.4236/ojrad.2013.33020    3,654 Downloads   6,207 Views  Citations

ABSTRACT

Objectives: There is an increasing use of three-dimensional rotational angiography (3D-RA) during catheterization of congenital heart disease. Dose-area-product (DAP) measured by the angiography system and computed-tomography dose index (CTDI) do not appear practical for dose assessment. Hence, we performed real dose measurements in anthropomorphic phantoms. Methods: Three different anthropomorphic phantoms (10 kg, 19 kg and 73 kg bodyweight) equipped with thermoluminescent dosimeters (TLD) were used. We used a typical standard diagnostic program and a low-dose program. The effective dose (ED) was calculated according to the International Commission on Radiological Protection (ICRP) 103. The 3D distribution of radiation in the body was assessed. Results: ED for the male 10 kg phantom was 0.192 mSv in the diagnostic program and 0.050 mSv (male) in the low-dose program. The 19 kg phantom received an ED of 0.205 mSv (male) in the diagnostic program. In the low-dose program the ED reached 0.058 mSv (male). The male adult 73 kg phantom was exposed with an ED of 0.730 mSv in the diagnostic program and 0.282 mSv in the low-dose program. ED for the female phantoms was slightly higher for both acquisition-programs. Dose distribution was inhomogeneous with a dose maximum in the esophageal region behind the heart, whereas in the brain, intestine and gonads we found nearly no radiation. Conclusions: 3D-RA imaging in the interventional catheter laboratory is possible with an effective dose lower than 1 mSv. With its potential to reduce fluoroscopic time and the number of control angiographies in catheterization and intervention in complex anatomy, it can decrease the radiation dose.

Share and Cite:

G. Reinke, J. Halbfaß, S. Dittrich, R. Banckwitz, C. Köhler, S. Achenbach, O. Rompel and M. Glöckler, "Three-Dimensional Rotational Angiography in Congenital Heart Disease: Estimation of Radiation Exposure," Open Journal of Radiology, Vol. 3 No. 3, 2013, pp. 124-129. doi: 10.4236/ojrad.2013.33020.

Cited by

[1] three-Dimensional Rotational Angiography during catheterization of congenital Heart Disease–A ten Years' experience at a single center
2020
[2] Three‐dimensional rotational angiography in congenital heart disease: Present status and evolving future
2019
[3] Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol
Pediatric Cardiology, 2018
[4] Radiation exposure by three-dimensional rotational angiography (3DRA) during trans-catheter melody pulmonary valve procedures (TMPV) in a pediatric cardiac …
Pediatric Cardiology, 2016
[5] Dosimetría a los pacientes pediátricos en cateterismos cardíacos e impacto de las adquisiciones en modo tomográfico
2016
[6] Diagnostic Utility of Three-Dimensional Rotational Angiography in Congenital Cardiac Catheterization
Pediatric Cardiology, 2016
[7] Radiation Exposure by Three-Dimensional Rotational Angiography (3DRA) During Trans-catheter Melody Pulmonary Valve Procedures (TMPV) in a Pediatric Cardiac …
Pediatric Cardiology, 2016
[8] Implantacja stentu do lewej tętnicy płucnej monitorowana angiografią rotacyjną z trójwymiarową rekonstrukcją
2015
[9] Komentarz
2015
[10] Patient doses in paediatric interventional cardiology: impact of 3D rotational angiography
Journal of Radiological Protection, 2015
[11] Udar mózgu jako pierwsza manifestacja migotania przedsionków—opis dwóch przypadków klinicznych
2015
[12] MENU Zaawansowane
Folia Cardiologica, 2015
[13] Estimation of eye lens doses received by pediatric interventional cardiologists
Applied Radiation and Isotopes, 2015
[14] Three-Dimensional Rotational Angiography in the Pediatric Cath Lab: Optimizing Aortic Interventions
Pediatric cardiology, 2015
[15] Multimodality 3-Dimensional Image Integration for Congenital Cardiac Catheterization
Methodist DeBakey cardiovascular journal , 2014
[16] Anwendung der dreidimensionalen Rotationsangiographie bei Kindern mit angeborenen Herzfehler-10 Jahre Erfahrung aus einer Single-Center-Studie
Dissertation, Erlangen

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.