Open Journal of Civil Engineering

Volume 3, Issue 3 (September 2013)

ISSN Print: 2164-3164   ISSN Online: 2164-3172

Google-based Impact Factor: 0.75  Citations  

Approach to Determine Corrosion Propensity in Post-Tensioned Tendons with Deficient Grout

HTML  XML Download Download as PDF (Size: 1178KB)  PP. 182-187  
DOI: 10.4236/ojce.2013.33022    5,440 Downloads   8,227 Views  Citations

ABSTRACT

After corrosion failure of post-tensioned tendons was identified in a Florida bridge in early 2011, laboratory tests were conducted in this study on extracted sections from the failed tendons to identify the grout properties and makeup leading to the failure and also to elucidate the mechanism of corrosion. The initial steps in identification of PT tendons with a high propensity for corrosion initiation or damaged included a detailed visual inspection and identification of voids in the grout. Voids in tendon can be a result of bleed water formation or construction problems. General characteristics of the deficient grout and corrosion behavior of steel in the affected bridge gave a first approach to assessing grout deficiency and corrosion susceptibility. However, refinements in the understanding of the mechanisms causing grout segregation and the elucidation of the role of sulfates, oxygen content, and pore water pH in corrosion development are required.

Share and Cite:

J. Rafols, K. Lau, I. Lasa, M. Paredes and A. ElSafty, "Approach to Determine Corrosion Propensity in Post-Tensioned Tendons with Deficient Grout," Open Journal of Civil Engineering, Vol. 3 No. 3, 2013, pp. 182-187. doi: 10.4236/ojce.2013.33022.

Cited by

[1] Review of Electrochemical Testing to Assess Corrosion of Post-Tensioned Tendons with Segregated Grout
Construction Materials, 2022
[2] Accelerated Corrosion Testing of Grouts for PT Steel Strand
2021
[3] Development of Standard Methodology to Measure Sulfate Ions in Post-Tensioned Grouts
2021
[4] Moisture and ion mobilization and stratification in post-tensioned (PT) grout during hydration
Case Studies in Construction Materials, 2021
[5] Evaluation of Corrosion Inhibiting Materials Applied by Impregnation (Pressure Injection) Methods to Prevent Corrosion of Post-Tensioned Tendons
2020
[6] Evaluation of Techniques to Remove Defective Grout from Post-Tensioning Tendons
2020
[7] Mechanism of Corrosion Mitigation of Post-Tensioned Tendons by Impregnation
2019
[8] Effect of grout conditions and tendon location on corrosion pattern in PS tendon in grout
Construction and Building Materials, 2018
[9] Evaluation of Shelf Life in Post-Tensioning Grouts
2018
[10] Impedance-Based Detection of Corrosion in Post-Tensioned Cables: Phase 2 from Concept to Application
2017
[11] ANALYSIS OF ASTM A416 TENDON STEEL CORROSION IN ALKALINE SIMULATED PORE SOLUTIONS
2016
[12] Feasibility of Cathodic Protection in Grouted Post Tensioned Tendons-Exploratory Model Calculations.
2016
[13] Impedance Analysis of ASTM A416 Tendon Steel Corrosion in Alkaline Simulated Pore Solutions
Corrosion Science, 2015
[14] Feasibility of Cathodic Protection in Grouted Post Tensioned Tendons-Exploratory Model Calculations
2015

Copyright © 2024 by authors and Scientific Research Publishing Inc.