We conducted a study to quantify the amount of pseudorange multipath at continuous Global Positioning System (CGPS) stations in the Mexican territory. These CGPS stations serve as reference stations enabling rapid high-precision three-dimensional positioning capabilities, supporting a number of commercial and public safety applications. We studied CGPS data from a large number of publicly available networks spanning Mexico. These include the RGNA (National Active Geodetic Network) administered by INEGI (National Institute of Statistics and Geography), the PBO network (Plate Boundary Observatory) funded by the National Science Foundation (NSF) and operated by UNAVCO (University NAVstar Consortium), the Southern California Integrated GPS Network (SCIGN), which is a collaboration effort of the United States Geological Survey (USGS), Scripps Institution of Oceanography and the Jet Propulsion Laboratory (JPL), the UNAM network, operated by the National Seismological System (SSN) and the Institute of Geophysics of the National Autonomous University of Mexico (UNAM), the Suominet Geodetic Network (SNG) and the CORS (Continuously Operating Reference Station) network, operated by the Federal Aviation Administration (FAA). We evaluated a total of 53 CGPS stations, where dual-frequency geodetic-grade receivers collected GPS data continuously during the period from 1994 to 2012. Despite carefully selected locations, all GPS stations are, to some extent, affected by the presence of signal multipath. For GPS network users that rely on pseudorange observables, the existence of pseudorange multipath could be a critical source of error depending on the time scale of the application. Thus, to identify the most and the least affected GPS stations, we analyzed the averaged daily root mean square pseudorange multipath variations (MP1-RMS and MP2-RMS) for all feasible satellites tracked by the CGPS networks. We investigated the sources of multipath, including changes associated with hardware replacement (i.e., receiver and antenna type) and receiver firmware upgrades.

Share and Cite:

G. Vázquez, R. Bennett and J. Spinler, "Assessment of Pseudorange Multipath at Continuous GPS Stations in Mexico," Positioning, Vol. 4 No. 3, 2013, pp. 253-265. doi: 10.4236/pos.2013.43025.

Cited by

[1] Quality assessment of Continuous Operating Reference Stations (CORS)-GPS stations in Mexico
Andrade, R Romero-Andrade… - Geodesy and …, 2022
[2] Snow Depth and Snow Water Equivalent Estimation
Theory and Practice of GNSS Reflectometry, 2021
[3] Análisis de calidad de las observaciones GPS y su impacto en el posicionamiento preciso. Caso de estudio: redes geodésicas GNSS de libre acceso en México
2021
[4] Precipitable Water Vapor Retrieval from Shipborne GNSS Observations on the Korean Research Vessel ISABU
2020
[5] Snow Depth Estimation Based on Combination of Pseudorange and Carrier Phase of GNSS Dual-Frequency Signals
2018
[6] Wide Area Augmentation System Estimating C1P1 DCB
2018
[7] Retrieving NDVI in midwestern America using GPS-interferometric reflectometry
Transactions of the Chinese Society of Agricultural Engineering, 2016
[8] 基于 GPS-IR 的美国中西部地区 NDVI 时间序列反演.
Transactions of the Chinese Society of Agricultural Engineering, 2016

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.