Open Journal of Radiology

Volume 3, Issue 2 (June 2013)

ISSN Print: 2164-3024   ISSN Online: 2164-3032

Google-based Impact Factor: 0.33  Citations  

Intra and Inter-Observer Reliability of Mobile Tablet PACS Viewer System vs. Standard PACS Viewing Station-Diagnosis of Acute Central Nervous System Events

HTML  Download Download as PDF (Size: 1114KB)  PP. 91-98  
DOI: 10.4236/ojrad.2013.32014    4,069 Downloads   6,898 Views  Citations

ABSTRACT

Background and Purpose: The display resolution of the Apple iPad? is 1024 × 768 pixels, which is greater than that required for generating the typical CT or MRI images. The purpose of this study is to determine if specific CT and MR sequences can be interpreted accurately on mobile device/PACS software platforms when compared to a traditional stationary high resolution monitor/PACS radiological workstation. If so, this allows radiologists to provide comparable interpretation as if they were onsite at an imaging center or hospital. Materials and Methods: This study is an investigator initiated, single site, retrospective, nonrandomized, IRB approved study. Five radiologists were included in this study. Each independently interpreted specific CT and MR sequences on traditional high-resolution LCD monitors via eFilm? software as well as an iPad? mobile device using Osirix? software program. Repeat interpretations were performed, with 4 weeks minimum interval between interpretations of each patient. This investigation included: 50 patients with CTA perfusion imaging, 50 patients with MRI of the brain, and 50 patients with MRI of the spine, which were image study orders generated through emergency room requests. Subsequently, interpretive results of each radiologist for each patient were statistically compared to evaluate for intra-observer and inter-observer reliability. Results: The parameters set within the CTA perfusion brain studies demonstrated excellent intra-observer variability. All of the parameters within the MRI brain studies demonstrated excellent intra-observer variability with a Cohen’s kappa value > 0.75. The Cohen’s kappa values for the board certified neuroradiologist demonstrated excellent variability for all parameters; the resident radiologists had good variability, with a majority of kappa values near 0.75. Conclusions: The data and statistical analysis demonstrated that portable mobile devices such as the Apple iPad? can display adequate resolution of CT and MRI sequences to accurately diagnose acute central nervous system injuries and other non-acute pathology.

Share and Cite:

A. Bhatia, S. Patel, G. Pantol, Y. Wu, M. Plitnikas and C. Hancock, "Intra and Inter-Observer Reliability of Mobile Tablet PACS Viewer System vs. Standard PACS Viewing Station-Diagnosis of Acute Central Nervous System Events," Open Journal of Radiology, Vol. 3 No. 2, 2013, pp. 91-98. doi: 10.4236/ojrad.2013.32014.

Cited by

[1] Dynamic Optimization for Fast Image Transfer and Visualization for Mobile and Stationary Devices: A Performance Evaluation Using Animati Viewer
[2] Development and Application of a Web-Based Platform for Assessment of Observer Performance in Medical Imaging
2022
[3] Accuracy and Reliability of the Recommendation for IV Thrombolysis in Acute Ischemic Stroke Based on Interpretation of Head CT on a Smartphone or a Laptop
2020
[4] SP-MIOV: A novel framework of shadow proxy based medical image online visualization in computing and storage resource restrained environments
2019
[5] Evaluation of the Accuracy Equivalence of Head CT Interpretations in Acute Stroke Patients Using a Smartphone, a Laptop, or a Medical Workstation
2019
[6] A Survey of Teleradiology: Future Trends
2019
[7] Vitamin D (25 (OH) D) in patients with chronic kidney disease stages 2-5
2019
[8] Remote Head CT Evaluation for Acute Stroke Diagnosis Using a Smartphone: Reliability and Diagnostic Equivalence with a Primary Medical Interpretation Workstation
The Eleventh International Conference on eHealth, Telemedicine, and Social Medicine, 2019
[9] Reliability of the Alberta stroke early CT scan (ASPECTS) and stroke classification in an emergency telestroke context
2018
[10] Diagnostic concordance between mobile interfaces and conventional workstations for emergency imaging assessment
International Journal of Medical Informatics, 2018
[11] Mobile device for thrombolysis decisions for telestroke
2018
[12] Dispositivo móvil para para decisiones de trombólisis mediante Telestroke Translated title (en): Mobile device for thrombolysis decisions for Telestroke
2018
[13] Dispositivo móvil para decisiones de trombólisis mediante telestroke
2018
[14] Ruling out brain CT contraindications prior to intravenous thrombolysis: diagnostic equivalence between a primary interpretation workstation and a mobile …
2017
[15] CT of the head for acute stroke: Diagnostic performance of a tablet computer prior to intravenous thrombolysis
Journal of medical imaging and radiation oncology, 2017
[16] Efficient medical image access in diagnostic environments with limited resources
2017
[17] Ruling Out Brain CT Contraindications prior to Intravenous Thrombolysis: Diagnostic Equivalence between a Primary Interpretation Workstation and a Mobile Tablet …
International Journal of Telemedicine and Applications, 2017
[18] Research Article Ruling Out Brain CT Contraindications prior to Intravenous Thrombolysis: Diagnostic Equivalence between a Primary Interpretation …
2017
[19] Mobile markerless augmented reality and its application in forensic medicine
International journal of computer assisted radiology and surgery, 2015
[20] Radiological interpretation of images displayed on tablet computers: a systematic review
The British journal of radiology, 2015
[21] Telemedicine Workplace Environments: Designing for Success
Healthcare, 2014
[22] Human Factors and Human-Computer Considerations in Teleradiology and Telepathology
Healthcare, 2014
[23] Teleradiology: current perspectives
2014

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.