ABSTRACT

Introduction: The inflatable penile prosthesis (IPP) has been used to treat erectile dysfunction for 40 years. Loss of penile length following IPP remains the single biggest patient complaint. We describe a preoperative and postoperative patient preparation protocol to assist in setting realistic patient expectations and decreasing the complaint of reduced penile length. Materials & Methods: 750 Patients are instructed to use a vacuum erection device for 10 minutes each day for up to 2 months prior to IPP implant. After two months, maximization of cylinder length is accomplished regardless of IPP manufacturer. Cylinders are left partially inflated in the post-operative period and daily inflation for 3 months immediately upon patient tolerance. The average implanted cylinder length has increased dramatically with the preoperative vacuum usage when compared to the authors’ previous implantations and when compared to the national average of implanted cylinders obtained from one manufacturer. Results: Preoperative use of the vacuum device has allowed maximization of cylinder length. After the vacuum program, patients tend to experience less pain following implantation allowing earlier device instruction cycling and use. The average implanted cylinder length continued to increase annually for the first 5 years as the protocol evolved and seems to have remained stable for the last five years. Conclusions: Preoperative vacuum usage and postoperative capsule management has nearly eliminated patient complaints of reduced penile length. We believe this to be the result of larger size cylinders being implanted when compared to our previous implantations absent of the patient participation protocol.

Share and Cite:

T. Sellers, M. Dineen, E. Salem and S. Wilson, "Vacuum Preparation, Optimization of Cylinder Length and Postoperative Daily Inflation Reduces Complaints of Shortened Penile Length Following Implantation of Inflatable Penile Prosthesis," Advances in Sexual Medicine, Vol. 3 No. 1, 2013, pp. 14-18. doi: 10.4236/asm.2013.31003.

Cited by

[1] Surgical tips in difficult penile prosthetic surgery: a narrative review
International Journal of …, 2022
[2] The Role of Penile Lengthening Procedures at the Time of Penile Implant Surgery
Penile Implant Surgery, 2022
[3] The Hostile Penis: Managing the Patient with Corporal Fibrosis
Penile Implant …, 2022
[4] Mon-Fri: 9: 00AM-10: 00PM Sat-Sun: Closed
Science, 2021
[5] Optimizing Outcomes in Penile Implant Surgery
Crespo, K Buscaino… - Urologic …, 2021
[6] Penile Prosthesis Implantation in Complex and Previously Failed Settings
2020
[7] “Make it as long as you can, Doc.” Concomitant surgical treatments with penile implant to enhance penile size
2020
[8] Cylinder insertion into scarred corporal bodies: prosthetic urology's most difficult challenge: some suggestions for making the surgery easier
2020
[9] Advanced Penile Length Restoration Techniques to Optimize Penile Prosthesis Placement Outcomes
2020
[10] A Thematic Analysis of the Online Discussion Board, FrankTalk, Regarding Penile Implant
2019
[11] Biomechanical Studies of the Inflatable Penile Prosthesis: A Review
2019
[12] Postoperative vacuum therapy following AMS™ LGX 700® inflatable penile prosthesis placement: penile dimension outcomes and overall satisfaction
2019
[13] Optimizing Outcomes in the Virgin Penile Implant Patient
2019
[14] Penile Traction Therapy and Vacuum Erection Devices in Peyronie's Disease
2018
[15] Preoperative counseling and expectation management for inflatable penile prosthesis implantation
2017
[16] Vacuum Therapy for Erectile Dysfunction
Contemporary Treatment of Erectile Dysfunction, 2016
[17] Is the daily use of vacuum erection device for a month before penile prosthesis implantation beneficial? a randomized controlled trial
Andrology, 2016
[18] Manufacturers' data show increasing implanted cylinder sizes and measured corporal lengths in inflatable penile implants
World journal of urology, 2015
[19] Penile Rehabilitation: The Evolutionary Concept in the Management of Erectile Dysfunction
Current urology reports?, Springer, 2014
[20] Current Management of Penile Implant Infections, Device Reliability, and Optimizing Cosmetic Outcome
Current urology reports?, Springer, 2014

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.