Journal of Analytical Sciences, Methods and Instrumentation

Volume 2, Issue 4 (December 2012)

ISSN Print: 2164-2745   ISSN Online: 2164-2753

Google-based Impact Factor: 0.42  Citations  

Coupling of on-Line Pre-Column Oxidative Cleavage and Solid-Phase Enrichment with Liquid Chromatography Using an Eco-Friendly Analytical Procedure to Determine Low Levels of Methotrexate

HTML  Download Download as PDF (Size: 197KB)  PP. 194-202  
DOI: 10.4236/jasmi.2012.24030    3,805 Downloads   6,888 Views  Citations

ABSTRACT

A simple, sensitive and precise green high-performance liquid chromatographic method including on-line pre-column oxidation combined by column switching with a short Hypersil ODS analytical column (100 mm × 4.0 mm i.d.) for enrichment and separation was developed and validated to determine low levels of methotrexate (MTX). The method was based on oxidative cleavage of MTX into highly fluorescence products, 2,4-diaminopteridine-6-carboxaldehyde and the corresponding 2,4-diaminopteridine-6-carboxylic acid, during the flow of phosphate buffer (0.04 M, pH 3.4) containing the analyte through the packed reactor of cerium (IV) trihydroxyhydroperoxide (CTH) at a flow-rate of 0.2 mL/min and 40℃. The fluorescent products were enriched on the head of ODS analytical column for the final separation. The separation was performed at room temperature using an environmentally friendly mobile phase consisting of ethanol and phosphate buffer (0.04 M, pH 3.4) in the ratio of 10:90 (v/v). The eluent was monitored at emission and excitation wavelengths of 463 and 367 nm, respectively. The method was successfully applied, without any interference from the excipients, for the determination of drug in tablets and vials with a detection limit of 0.06 ng/mL from 500 ?L of sample MTX.

Share and Cite:

S. Emara, W. Zarad, M. Kamal and R. EL-Bagary, "Coupling of on-Line Pre-Column Oxidative Cleavage and Solid-Phase Enrichment with Liquid Chromatography Using an Eco-Friendly Analytical Procedure to Determine Low Levels of Methotrexate," Journal of Analytical Sciences, Methods and Instrumentation, Vol. 2 No. 4, 2012, pp. 194-202. doi: 10.4236/jasmi.2012.24030.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.