Journal of Biomaterials and Nanobiotechnology

Volume 3, Issue 2 (May 2012)

ISSN Print: 2158-7027   ISSN Online: 2158-7043

Google-based Impact Factor: 1.69  Citations  

Modern Monitoring Intraocular Pressure Sensing Devices Based on Application Specific Integrated Circuits

HTML  XML Download Download as PDF (Size: 373KB)  PP. 301-309  
DOI: 10.4236/jbnb.2012.322037    7,705 Downloads   13,542 Views  Citations

ABSTRACT

Glaucoma is a neurodegenerative condition that is the leading cause of irreversible blindness worldwide. Elevated intraocular pressure (IOP) is the main risk factor for the development and progression of the disease. Methods to lower IOP remain the first line treatments for the condition. Current methods of IOP measurement do not permit temporary noninvasive monitoring 24-hour IOP on a periodic basis. Ongoing research will in time provide a means of developing a device that will enable continuous or temporary monitoring of IOP. At present a device suitable for clinical use is not yet available.This review contains a description of different devices currently in development for measuring IOP: soft contact lens, LC resonant circuits and on-chip sensing devices. All of them use application-specific integrated circuits (ASICS) to process the measured signals and send them to recording devices. Soft contact lens devices are based on an embedded strain gauge, LC circuits vary their resonance frequency depending on the intraocular pressure (IOP) and, finally, on-chip sensing devices include an integrated microelectromechanical sensor (MEMS). MEMS are capacitors whose capacity varies with IOP. These devices allow for an accurate IOP measurement (up to +/– 0.2 mm Hg) with high sampling rates (up to 1 sample/min) and storing 1 week of raw data. All of them operate in an autonomous way and even some of them are energetically independent.

Share and Cite:

D. Piso, P. Veiga-Crespo and E. Vecino, "Modern Monitoring Intraocular Pressure Sensing Devices Based on Application Specific Integrated Circuits," Journal of Biomaterials and Nanobiotechnology, Vol. 3 No. 2A, 2012, pp. 301-309. doi: 10.4236/jbnb.2012.322037.

Cited by

[1] A Meta-Analysis of Wearable Contact Lenses for Medical Applications: Role of Electrospun Fiber for Drug Delivery
Chapa, M Sher - Polymers, 2022
[2] The Potential of Noninvasive Micro-electromechanical Systems in Intraocular Pressure
Indian Journal of VLSI Design, 2021
[3] The Revolutionary Potential of Noninvasive Micro-electromechanical Systems in Intraocular Pressure Management
Indian Journal of VLSI Design, 2021
[4] A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure
2021
[5] An Ultrasensitive Contact Lens Sensor Based On Self‐Assembly Graphene For Continuous Intraocular Pressure Monitoring
2021
[6] Current view and prospect: Implantable pressure sensors for health and surgical care
2020
[7] 질병 진단용 스마트 콘택트렌즈 바이오 센서의 연구 동향
2019
[8] Wirelessly powered signal regeneration to improve the remote detectability of an inductive pressure sensor
2019
[9] Recent Advances in Smart Contact Lenses
2019
[10] Remote characterization of resonance frequency with a wirelessly powered parametric oscillator
2019
[11] Обзор методов контроля внутриглазного давления с помощью нано-и микроструктурированных контактных линз
2018
[12] None Invasive Intraocular Pressure Control Simulation: PF-04475270 Case Study
2018
[13] Materials and Manufacture of Soft and Curvilinear Electronics
2018
[14] Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays
2018
[15] Noninvasive Glucose Monitoring with a Contact Lens and Smartphone
Sensors, 2018
[16] A Wirelessly Powered Smart Contact Lens with Reconfigurable Wide Range and Tunable Sensitivity Sensor Readout Circuitry
Sensors, 2017
[17] Assessment of intraocular pressure sensing using an implanted reflective flexible membrane
2017
[18] Split-ring resonator-based sensors on flexible substrates for glaucoma monitoring
Sensors and Actuators A: Physical, 2017
[19] Intraocular Pressure Model Predictive Control: A Simulation of Circadian and Mean Intraocular Pressure Control
2016
[20] Hermetic capacitive pressure sensors for biomedical applications Daniela Diaz-Alonso Mario Moreno-Moreno Carlos Zuñiga Joel Molina Wilfrido Calleja Juan …
2016
[21] Toward a Wirelessly Powered On-Lens Intraocular Pressure Monitoring System.
2016
[22] Hermetic capacitive pressure sensors for biomedical applications
Microelectronics International, 2016
[23] Toward A Wirelessly Powered On-lens Intraocular Pressure Monitoring System
2016
[24] Design of NEMS Based Intraocular Pressure Sensing System
Procedia Technology, 2016
[25] Split-Ring Resonator-Based Strain Sensor on Flexible Substrates for Glaucoma Detection
Journal of Physics: Conference Series, 2016
[26] An addressable UHF EPCGlobal Class1 Gen2 Sensor IC for wireless IOP monitoring on contact lens
VLSI Design, Automation and Test (VLSI-DAT), 2015 International Symposium on, 2015
[27] Continuous Intraocular Pressure Monitoring by Non-Invasive Wireless Pressure Sensor
International Journal, 2015
[28] An RFID-based on-lens sensor system for long-term IOP monitoring
Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE, 2015
[29] Continuous Monitoring of Intraocular Pressure From the Sclera
2013
[30] DISE?O Y FABRICACIóN DE UN SENSOR DE PRESIóN CAPACITIVO IMPLANTABLE PARA MONITOREAR PRESIóN INTRAOCULAR
2013
[31] Dept. of Electr. Eng., King Abdullah Univ.(KAUST) of Sci. & Technol., Thuwal, Saudi Arabia
Antennas and …, 2012

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.