Design and development of a new dedicated RF sensor for the MRI of rat brain

HTML  Download Download as PDF (Size: 3422KB)  PP. 167-180  
DOI: 10.4236/jbise.2010.32022    6,520 Downloads   12,893 Views  Citations
Author(s)

Affiliation(s)

.

ABSTRACT

The design and development of a new dual-frequency RF probe-head are presented. This probe was initially dedicated for the MRI of both proton (1H) and hyperpolarized Xenon-129 (HP 129Xe) in the rat brain at 2.35 Tesla. It consists of a double-tuned (100 MHz- 27.7 MHz) volume coil, which could be used for both transmitting and receiving, and of a receive-only single-tuned (27.7 MHz) coil. The double-tuned coil consists of two concentric birdcage resonators. The inner one is a low-pass design and it is tuned to 27.7 MHz, while the outer one, tuned to 100 MHz, is high-pass. The receive-only coil is a surface coil which is decoupled from the double-tuned volume coil by an active decoupling circuitry based on the use of PIN diodes. A home-built Transmit/Receive (T/R) driver ensures biasing of the PIN diodes in both volume and surface coils. The original concepts of the design are addressed, and practical details of realization are presented. One of the underlying ideas behind this work is to proceed well beyond the application to the MRI of HP 129Xe. Actually, this design could be easily adapted for a large palette of other MRI applications. Indeed, we tried to make the design versatile, simple and easy to replicate by other research groups, with a low-cost, minimum development time and accepted performances. The prototype was validated at 100 MHz and at 26.4 MHz (sodium-23 resonance frequency at 2.35 T). MRI experiments were performed using phantoms. In vivo 1H images and 23Na spectra of the rat brain are also presented.

Share and Cite:

Asfour, A. (2010) Design and development of a new dedicated RF sensor for the MRI of rat brain. Journal of Biomedical Science and Engineering, 3, 167-180. doi: 10.4236/jbise.2010.32022.

Cited by

[1] Design and Construction of a PET-Compatible Double-Tuned 1H/31P MR Head Coil
2021
[2] The state-of-the-art and emerging design approaches of double-tuned RF coils for X-nuclei, brain MR imaging and spectroscopy: A review
2020
[3] Cewki RF–rola w systemie MRI oraz przegląd wybranych rozwiązań
2020
[4] Advancement in Biomedical Magnetic Resonance Imaging and Spectroscopy
2017
[5] Design and Development of a General‐Purpose Transmit/Receive (T/R) Switch for 3T MRI, Compatible for a Linear, Quadrature and Double‐Tuned RF Coil
Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering, 2016
[6] Design and Development of Dual Tuned 19F and 1H RF Birdcage Coils for Small Animal MRI at 3T.
2015
[7] Design of a two-channel NMR coil using an impedance transformation approach
Sensors Journal, IEEE, 2012
[8] A novel NMR instrument for the in-situ monitoring of the absolute polarization of laser-polarized 129Xe
Journal of Biomedical Science and Engineering, 2010