Open Journal of Anesthesiology

Volume 11, Issue 5 (May 2021)

ISSN Print: 2164-5531   ISSN Online: 2164-5558

Google-based Impact Factor: 0.23  Citations  

Comparison of Entropy vs. Bispectral Index Anesthetic Depth Monitoring during Isoflurane Anesthesia in Living Donor Liver Transplantation: Observational Study

HTML  XML Download Download as PDF (Size: 1183KB)  PP. 137-148  
DOI: 10.4236/ojanes.2021.115013    347 Downloads   1,094 Views  

ABSTRACT

Liver transplantation (LT) recipients are known to require less anesthetic agents. Providing minimally required anesthetics while avoiding awareness is especially important in LT recipients because it would help manage perioperative hemodynamic instability with less vasopressor and fast track recovery. This study aims to compare state entropy (SE) against bispectral index (BIS) during isoflurane anesthesia in LT. We adjusted anesthesia to BIS values 40 - 60, and compared it with concomitant SE values. BIS, SE values, and anesthetic requirements according to liver failure severity, etiology and LT stages were analyzed. For BIS-SE differences, SE value that is different from the concomitant BIS by more than 15 was defined as a significant disagreement. Mann Whitney, Kruskal Wallis test and a Poisson exact test were used for analysis. The BIS-SE pair sets of 2895 from 38 patients were analyzed. BIS, SE values and anesthetic requirements were significantly lower in MELD ≥ 20 (p < 0.001 in all) and in alcoholic etiology (p < 0.001 in all). For BIS-SE differences, 320 disagreement data pairs were seen at a rate of 1.33 times/hr (95% CI = [1.19, 1.48], p < 0.001). A significant disagreement was delineated in MELD score ≥ 20 (3.04 times/hr, CI = [2.64, 3.49], p < 0.001), alcoholic etiology (3.19 times/hr, [2.67, 3.78], p < 0.001) and postreperfusion stage (1.63 times/hr, [1.43, 1.85], p < 0.001). In these significant BIS-SE differences, 95.9% (307/320 disagreement data pairs) showed higher BIS than SE. In conclusion, in high MELD and alcoholic etiology, anesthetic requirements were significantly less, and BIS and SE showed great discrepancy with lower SE values. Therefore, when SE monitoring is used during LT, anesthesiologists may need to consider that in high MELD and alcoholic etiology, SE tends to show lower values than the concomitant BIS values that are within optimal anesthetic depth ranges.

Share and Cite:

Lee, S. , Jang, J. , Kim, K. , Yoo, H. , Bang, Y. , Choi, J. and Kim, G. (2021) Comparison of Entropy vs. Bispectral Index Anesthetic Depth Monitoring during Isoflurane Anesthesia in Living Donor Liver Transplantation: Observational Study. Open Journal of Anesthesiology, 11, 137-148. doi: 10.4236/ojanes.2021.115013.

Cited by

No relevant information.