Freeze-Thaw Effect on Coarse Sand Coated Interface between FRP and Concrete

HTML  Download Download as PDF (Size: 1363KB)  PP. 807-815  
DOI: 10.4236/eng.2013.510097    3,759 Downloads   5,856 Views  Citations

ABSTRACT

This paper examines the effect of freezing and thawing on the coarse sand coating chosen to achieve the composition of FRP and concrete in FRP-concrete composite deck. Push-out test specimens with dimensions of 100 × 100 × 450 mm were subjected to repeated freeze-thaw cycles under wet conditions ranging from -18± 2to 4 ± 2. The failure strength of the interface and the deformation of FRP at failure exhibited by the specimens that experienced 300 freezing-thawing cycles showed a difference of merely 5% compared to those of the specimens that were not subjected to freeze-thaw. This indicates that coarse sand coating is not affected by freezing-thawing cycles and the FRP-concrete composite deck owns sufficient applicability in terms of durability against freezing-thawing.

Share and Cite:

Cho, K. , Park, S. , Kim, S. , Cho, J. and Kim, B. (2013) Freeze-Thaw Effect on Coarse Sand Coated Interface between FRP and Concrete. Engineering, 5, 807-815. doi: 10.4236/eng.2013.510097.