Comparing a small gravel-less perforated pipe leach fields (GPPLF) to a medium one in treating domestic sewage

HTML  XML Download Download as PDF (Size: 1418KB)  PP. 192-197  
DOI: 10.4236/ns.2012.43029    4,145 Downloads   7,298 Views  

ABSTRACT

There were obvious differences between a medium gravel-less perforated pipe leach fields and a small system in the treatment of demestic sewage with the change of influent quality. In small system, COD removal rate was 91%, ammonia nitrogen removal rate was 90%, total nitrogen was 58%. In medium system, COD removal rate was 86.07%, ammonia nitrogen removal rate was 45.3%, and total nitrogen was 48.2%. This paper studied on the differences. Its main reasons were as follows: differences in opening rate (perforated area account of the total area in infiltration pipe), air flow conditions, exterior environment, and wastewater distribution. Considering those problems, Solutions and applications for the development of GPPLF are given.

Share and Cite:

Yang, Y. , Wang, C. and Dang, Z. (2012) Comparing a small gravel-less perforated pipe leach fields (GPPLF) to a medium one in treating domestic sewage. Natural Science, 4, 192-197. doi: 10.4236/ns.2012.43029.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License