Time Domain Modeling of Powerline Impulsive Noise at Its Source

Abstract

Noise characteristics of an indoor power line network strongly influence the link capability to achieve high data rates. The appliances shared with PLC modems in the same powerline network generate different types of noises, among them the impulsive noises are the main source of interference resulting in signal distortions and bit errors during data transmission. With regard to impulsive noise many models were proposed in the literature and shared the same impulsive noise definition: “unpredictable noises measured in the receiver side”. Authors are, consequently, confronted to model thousands of impulsive noises whose plurality would very likely come from the diversity of paths that the original impulsive noise took. In this paper, an innovative modelling approach is applied to impulsive noises which are studied here directly at their sources. Noise at receiver would be simply the noise model at source convolved by powerline channel block. In the new analytical model, the impulsive noise at source is described by a succession of short pulses, each modeled by a phase-shifted Gaussian. Noises at source are classified into 6 different classes [1], and a noise generator is established for each class.

Share and Cite:

H. Chaouche, F. Gauthier, A. Zeddam, M. Tlich and M. Machmoum, "Time Domain Modeling of Powerline Impulsive Noise at Its Source," Journal of Electromagnetic Analysis and Applications, Vol. 3 No. 9, 2011, pp. 359-367. doi: 10.4236/jemaa.2011.39057.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] M. Tlich, H. Chaouche, A. Zeddam and P. Pagani, “Novel Approach for PLC Impulsive Noise Modelling,” IEEE International Symposium on Power Line Communications and Its Applications, Dresden, 29 March-1 April 2009, pp. 20-25.
[2] K. Dostert, “Telecommunications over Power Distribution Grid: Possibilities and Limitations,” International Symposium on Power-Line Communications and Its Applications, Essen, 2-4 April 1997.
[3] M. Zimmermann and K. Dostert, “A Multi-path Signal Propagation Model for the Powerline Channel in the High Frequency Range,” International Symposium on Power-Line Communications and Its Applications, Lancaster, 30 March-1 April 1999, pp. 45-51.
[4] T. Esmailian, P. G. Gulak and F. R. Kschischang, “A Discrete Multitone Power Line Communications System,” Proceedings of the Acoustics, Speech, and Signal Processing, Vol. 5, Istanbul, 5-9 June 2000, pp. 2953-2956.
[5] E. Liu, Y. Gao, G. Samdani, Omar Mukhtar and T. Korhonen, “Broadband Power-lLine Channel and Capacity Analysis,” International Symposium on Power-Line Communications and Its Applications, Vancouver, 6-8 April 2005, pp. 7-11.
[6] H. Meng and S. Chen, “Modeling of Transfer Characteristics for the Broadband Power Line Communication Channel,” IEEE Transactions on Power Delivery, Vol. 19, No. 3, 2004, pp. 529-551. doi:10.1109/TPWRD.2004.824430
[7] M. Zimmermann and K. Dostert, “A Multi-path Model for the Power Line Channel,” IEEE Transactions on Communications, Vol. 50, No. 4, 2002, pp. 553-559. doi:10.1109/26.996069
[8] H. Philipps, “Development of a Statistical Model for Power Line Communications Channels,” International Symposium on Power-Line Communications and Its Applications, Limerick, 5-7 April 2000, pp. 153-160.
[9] D. Anastasiadou and T. Antonakoupoulos, “Multipath Characterization of Indoor Power-Line Networks,” IEEE Transactions on Power Delivery, Vol. 20, No. 1, 2005, pp. 90-99. doi:10.1109/TPWRD.2004.832373
[10] P. Amirshahi and M. Kavehrad, “Transmission Channel Model and Capacity of Overhead Multi-conductor Medium-Voltage Powerlines for Broadband Communications,” International Symposium on Power-Line Communications and Its Applications, Zaragoza, 31 March-2 April 2004, pp. 354-358.
[11] A. Rennane, C. Konate and M. Machmoum, “A Simplified Deterministic Approach to Accurate Modeling of Transfer Function for the Broadband Power Line Communication,” INTECH, Morn Hill, 2010, pp. 1-18.
[12] H. Heng, S. Chen, Y. L. Guan and C. L. Law, “Modeling of Transfer Characteristics of the Broadband Power Line Communication Channel,” IEEE Transactions on Power Delivery, Vol. 19, No. 3, 2004, pp. 1057-1064. doi:10.1109/TPWRD.2004.824430
[13] M. Tlich, A. Zeddam, F. Moulin, F. Gauthier and G. Avril, “A Boadband Powerline Channel Generator,” Proceedings of the IEEE International Conference on Power Line Communications and Its Applications, Pisa, 26-28 March 2007, pp. 505-510.
[14] M. Tlich, A. Zeddam, F. Moulin and F. Gauthier, “Indoor Power-Line Communications Channel Characterization up to 100 MHz. Part I: One-Parameter Deterministic Model,” IEEE Transactions on Power Delivery, Vol. 23, No. 3, 2008, pp. 1392-1401. doi:10.1109/TPWRD.2008.919397
[15] G. Avril, M. Tlich, F. Moulin, A. Zeddam and F. Nouvel, “Time/Frequency Analysis of Impulsive Noise on Powerline Channels,” 1st International Home Networking Conference, Paris, 10-12 December 2007, pp. 143-150.
[16] M. Zimmermann and K. Dostert, “An Analysis of the Broadband Noise Scenario in Power-Line Networks,” International Symposium on Power-Line Communications and Its Applications, Limerick, 5-7 April 2000, pp. 131-138.
[17] V. B. Balakirsky and A. J. H. Vinck, “Potential Limits on Powerline Communication over Impulsive Noise Channels,” International Symposium on Power-Line Communications and Its Applications, Kyoto, 26-28 March 2003, pp. 32-36.
[18] V. Degardin, M. Lienard, P. Degauque, A. Zeddam and F. Gauthier, “Impulsive Noise on Indoor Power Lines: Characterization and Mitigation of Its Effect on PLC Systems,” IEEE International Symposium on Electromagnetic Compatibility, Istanbul, 11-16 May 2003, Vol. 1, pp. 166-169.
[19] F. Rouissi, “Optimisation de la couche Physique des Systèmes de Communication sur le Réseau d'énergie en Présence de Bruit Impulsif,” Thesis, Lille, May 2008.
[20] H. Chaouche, A. Zeddam, F. Gauthier, M. Tlich and M. Machmoum, “Mesure et Modelisation du Bruit Impulsif à la Source,” 15ème Colloque International et Exposition sur la Compatibilité électromagnétiqu, Limoges, 7-9 April 2010, pp. 3-4.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.